  "schema": "vx-inventor-package/1",
  "status": "preliminary — not certified, not construction-ready",
  "exported": "2026-11-25T06:30:52.034Z",
  "revision": null,
  "verdict": {
    "class": "conditional",
    "reasons": [
      "All 5 mandatory calculations pass on the stated assumptions."
    ],
    "conditions": [
      "G-01: Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?",
      "G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?",
      "A-01 must be confirmed: PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast.",
      "A-02 must be confirmed: Active cell area 10 m² at 21.5 % module efficiency.",
      "A-03 must be confirmed: Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0.",
      "A-05 must be confirmed: Allowable soil bearing 150 kPa, friction 0.45.",
      "CALC-03: Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer",
      "CALC-04: Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)",
      "CALC-05: Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)"
    ],
    "counts": {
      "runs": 5,
      "pass": 2,
      "warn": 3,
      "fail": 0,
      "invalid": 0,
      "blocking_gaps": 2,
      "unapproved_high": 4
    },
    "label": "Conditional feasibility"
  },
  "record": {
    "key": "solar-hive",
    "name": "Solar Hive",
    "tagline": "Modular hexagonal solar cells clustered on a tracking mast (placeholder reading — import the invention's description).",
    "summary": "A cluster of hexagonal PV 'cells' — modules in hexagonal frames — mounted around a central mast on a dual-axis tracking head, so modules can be added like cells of a hive and the whole cluster follows the sun. This is a placeholder architecture: it exists to exercise the solar standards, structural and energy methods until the Solar Hive's own documents are imported.",
    "status_note": "Placeholder architecture (A-01). The plan cannot be approved until gap G-01 is closed with the inventor's description.",
    "brief": {
      "function": "Generate electricity from sunlight with a modular, expandable cluster that tracks the sun.",
      "environment": "Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code.",
      "scale": "Prototype: 7 hexagonal cells, ≈ 10 m² active area (assumed).",
      "budget": "Not yet stated.",
      "constraints": [
        "Modules certified to IEC 61215 / 61730",
        "Tracker must stow in high wind",
        "Compare against a fixed-tilt array of the same modules"
      ]
    },
    "requirements": [
      {
        "code": "REQ-PERF-001",
        "kind": "performance",
        "text": "Rated DC output of the prototype cluster.",
        "target": "≥ 2 kW DC at STC",
        "priority": "must",
        "verification": "test",
        "critical": true
      },
      {
        "code": "REQ-PERF-002",
        "kind": "performance",
        "text": "Annual energy shall be compared with a fixed-tilt array using the same modules.",
        "target": "kWh/kWp with uncertainty",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-SAFE-001",
        "kind": "safety",
        "text": "Survive the design wind in stow position.",
        "target": "ASCE 7 basic wind speed for the site (assumed 50 m/s)",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-SAFE-002",
        "kind": "safety",
        "text": "Stow automatically above a set wind speed and on loss of power.",
        "target": "stow ≤ 90 s from trigger",
        "priority": "must",
        "verification": "test",
        "critical": true
      },
      {
        "code": "REQ-STR-001",
        "kind": "safety",
        "text": "The mast foundation shall resist overturning and sliding within allowable soil bearing.",
        "target": "FS ≥ 1.5; q ≤ q_allow",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-MOD-001",
        "kind": "functional",
        "text": "Cells shall be added or replaced without disturbing neighbouring cells.",
        "target": "one cell swap ≤ 30 min",
        "priority": "should",
        "verification": "demonstration",
        "critical": false
      },
      {
        "code": "REQ-REG-001",
        "kind": "regulatory",
        "text": "Modules, racking and inverter listed for the jurisdiction.",
        "target": "IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690",
        "priority": "must",
        "verification": "inspection",
        "critical": false
      },
      {
        "code": "REQ-LIFE-001",
        "kind": "life",
        "text": "Design life.",
        "target": "25 years (modules), 20 years (tracker drives)",
        "priority": "must",
        "verification": "analysis",
        "critical": false
      }
    ],
    "functions": [
      {
        "code": "F1",
        "name": "Convert sunlight to electricity",
        "modes": [
          "day",
          "partial shade"
        ],
        "subsystem": "1.1"
      },
      {
        "code": "F2",
        "name": "Point the cluster at the sun; stow in high wind",
        "modes": [
          "tracking",
          "stow",
          "night"
        ],
        "subsystem": "1.2"
      },
      {
        "code": "F3",
        "name": "Carry the cluster and its wind load",
        "modes": [
          "all"
        ],
        "subsystem": "1.3"
      },
      {
        "code": "F4",
        "name": "Anchor to the ground",
        "modes": [
          "all"
        ],
        "subsystem": "1.4"
      },
      {
        "code": "F5",
        "name": "Condition and deliver power",
        "modes": [
          "grid-tied"
        ],
        "subsystem": "1.5"
      }
    ],
    "nodes": [
      {
        "id": "1",
        "parent": null,
        "level": "system",
        "name": "Solar Hive cluster (placeholder architecture)",
        "discipline": "systems",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [],
        "analyses": [],
        "requirements": [
          "REQ-PERF-001",
          "REQ-PERF-002",
          "REQ-LIFE-001"
        ]
      },
      {
        "id": "1.1",
        "parent": "1",
        "level": "subsystem",
        "name": "Hexagonal PV cells",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iec-61215",
          "iec-61730"
        ],
        "analyses": [
          "solar.pv_output"
        ],
        "requirements": [
          "REQ-PERF-001",
          "REQ-MOD-001"
        ],
        "function": "F1"
      },
      {
        "id": "1.1.1",
        "parent": "1.1",
        "level": "part",
        "name": "PV laminates cut / built to hexagonal format",
        "discipline": "electrical_power",
        "quantity": 7,
        "make_buy": "tbd",
        "standards": [
          "iec-61215",
          "iec-61730"
        ],
        "analyses": [],
        "requirements": [],
        "component": "sol-module",
        "material": "si-mono-perc",
        "cost": {
          "low": 1400,
          "high": 4200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Custom-format laminates need their own IEC 61215 qualification — or use standard rectangular modules in hex frames",
        "notes": "Key cost/certification question (G-02)"
      },
      {
        "id": "1.1.2",
        "parent": "1.1",
        "level": "part",
        "name": "Hexagonal cell frames",
        "discipline": "structural",
        "quantity": 7,
        "make_buy": "make",
        "standards": [
          "ul-3703"
        ],
        "analyses": [],
        "requirements": [],
        "material": "al-6063-t6",
        "cost": {
          "low": 700,
          "high": 2100,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Frame carries 2400 Pa wind / 5400 Pa snow test loads"
      },
      {
        "id": "1.1.3",
        "parent": "1.1",
        "level": "part",
        "name": "Cell-to-hub quick connectors",
        "discipline": "mechanical",
        "quantity": 7,
        "make_buy": "make",
        "standards": [
          "iso-898-1"
        ],
        "analyses": [
          "bolt.joint"
        ],
        "requirements": [],
        "material": "ss-316",
        "cost": {
          "low": 200,
          "high": 600,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Cell swap without tools in ≤ 30 min; bonding path maintained"
      },
      {
        "id": "1.1.4",
        "parent": "1.1",
        "level": "part",
        "name": "DC wiring, connectors and bonding",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "nfpa-70",
          "ul-3703"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 150,
          "high": 500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "NEC 690 wiring; equipment grounding continuity"
      },
      {
        "id": "1.2",
        "parent": "1",
        "level": "subsystem",
        "name": "Tracking head",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "ul-3703",
          "iso-13849"
        ],
        "analyses": [
          "bearing.life"
        ],
        "requirements": [
          "REQ-SAFE-002"
        ],
        "function": "F2"
      },
      {
        "id": "1.2.1",
        "parent": "1.2",
        "level": "part",
        "name": "Azimuth slew drive",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-281"
        ],
        "analyses": [],
        "requirements": [],
        "component": "sol-tracker",
        "cost": {
          "low": 500,
          "high": 1500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Holding torque ≥ stow wind moment × 1.5"
      },
      {
        "id": "1.2.2",
        "parent": "1.2",
        "level": "part",
        "name": "Elevation actuator",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "component": "sol-tracker",
        "cost": {
          "low": 250,
          "high": 800,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Drives to stow on backup power"
      },
      {
        "id": "1.2.3",
        "parent": "1.2",
        "level": "part",
        "name": "Hub slewing bearing",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-281",
          "iso-76"
        ],
        "analyses": [
          "bearing.life"
        ],
        "requirements": [],
        "component": "brg-slew",
        "cost": {
          "low": 400,
          "high": 1200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Static safety ≥ 2 at stow wind moment"
      },
      {
        "id": "1.2.4",
        "parent": "1.2",
        "level": "assembly",
        "name": "Tracker controller with wind-stow",
        "discipline": "electronics",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iso-13849",
          "iec-61000"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 300,
          "high": 1200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Sun-position tracking ±1°; stow on anemometer or power loss",
        "notes": "Routed to VX Design"
      },
      {
        "id": "1.3",
        "parent": "1",
        "level": "subsystem",
        "name": "Mast",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "aisc-360",
          "asce-7"
        ],
        "analyses": [
          "wind.thrust",
          "column.buckling",
          "bolt.joint"
        ],
        "requirements": [
          "REQ-SAFE-001"
        ],
        "function": "F3"
      },
      {
        "id": "1.3.1",
        "parent": "1.3",
        "level": "part",
        "name": "Steel mast tube",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aisc-360"
        ],
        "analyses": [
          "wind.thrust",
          "column.buckling"
        ],
        "requirements": [],
        "material": "astm-a500-c",
        "component": "str-tower-tube",
        "cost": {
          "low": 600,
          "high": 1800,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Member checks by structural engineer"
      },
      {
        "id": "1.3.2",
        "parent": "1.3",
        "level": "part",
        "name": "Mast base plate and flange bolts",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aisc-360",
          "iso-898-1"
        ],
        "analyses": [
          "bolt.joint"
        ],
        "requirements": [],
        "material": "astm-a36",
        "component": "fst-bolt",
        "cost": {
          "low": 250,
          "high": 700,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Plate and bolt checks"
      },
      {
        "id": "1.4",
        "parent": "1",
        "level": "subsystem",
        "name": "Foundation",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "aci-318",
          "asce-7",
          "ibc"
        ],
        "analyses": [
          "foundation.spread_footing",
          "anchor.bolt_circle"
        ],
        "requirements": [
          "REQ-STR-001"
        ],
        "function": "F4"
      },
      {
        "id": "1.4.1",
        "parent": "1.4",
        "level": "part",
        "name": "Reinforced-concrete pad",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aci-318"
        ],
        "analyses": [
          "foundation.spread_footing"
        ],
        "requirements": [],
        "material": "concrete-28",
        "component": "str-footing",
        "cost": {
          "low": 1500,
          "high": 4000,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "FS ≥ 1.5; bearing within allowable"
      },
      {
        "id": "1.4.2",
        "parent": "1.4",
        "level": "part",
        "name": "Anchor rods",
        "discipline": "structural",
        "quantity": 8,
        "make_buy": "buy",
        "standards": [
          "astm-f1554",
          "aci-318"
        ],
        "analyses": [
          "anchor.bolt_circle"
        ],
        "requirements": [],
        "component": "fst-anchor",
        "material": "anchor-f1554-55",
        "cost": {
          "low": 250,
          "high": 700,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Steel and breakout checks"
      },
      {
        "id": "1.5",
        "parent": "1",
        "level": "subsystem",
        "name": "Power conversion and interconnection",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "ul-1741",
          "ieee-1547",
          "nfpa-70"
        ],
        "analyses": [],
        "requirements": [
          "REQ-REG-001"
        ],
        "function": "F5"
      },
      {
        "id": "1.5.1",
        "parent": "1.5",
        "level": "part",
        "name": "Microinverters or string inverter with MLPE",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "ul-1741",
          "ieee-1547"
        ],
        "analyses": [],
        "requirements": [],
        "component": "pwr-rectifier-inv",
        "cost": {
          "low": 600,
          "high": 1800,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Listed; rapid shutdown (NEC 690.12)"
      }
    ],
    "interfaces": [
      {
        "id": "I-01",
        "a": "1.1.2",
        "b": "1.1.3",
        "kind": "structural",
        "description": "Cell frame to hub connector: wind and snow load path, bonding",
        "defined": false
      },
      {
        "id": "I-02",
        "a": "1.1.3",
        "b": "1.2.3",
        "kind": "structural",
        "description": "Cluster hub to tracking head bearing",
        "defined": false
      },
      {
        "id": "I-03",
        "a": "1.2.4",
        "b": "1.2.1",
        "kind": "signal",
        "description": "Controller to slew drive and actuator",
        "defined": false
      },
      {
        "id": "I-04",
        "a": "1.3.2",
        "b": "1.4.2",
        "kind": "structural",
        "description": "Mast base plate to anchor rods",
        "defined": false
      },
      {
        "id": "I-05",
        "a": "1.1.4",
        "b": "1.5.1",
        "kind": "electrical",
        "description": "Cell DC outputs to inverters",
        "defined": false
      }
    ],
    "assumptions": [
      {
        "code": "A-01",
        "text": "PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast.",
        "sensitivity": "high",
        "affects": [
          "1"
        ],
        "approved": false
      },
      {
        "code": "A-02",
        "text": "Active cell area 10 m² at 21.5 % module efficiency.",
        "value": "10 m², 21.5 %",
        "sensitivity": "high",
        "affects": [
          "1.1"
        ],
        "approved": false
      },
      {
        "code": "A-03",
        "text": "Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0.",
        "value": "PSH 6.0 (tracked)",
        "sensitivity": "high",
        "affects": [
          "1.1"
        ],
        "approved": false
      },
      {
        "code": "A-04",
        "text": "Design wind 50 m/s, cluster stowed flat (drag coefficient 1.3 on 30 % projected area).",
        "value": "50 m/s",
        "sensitivity": "medium",
        "affects": [
          "1.3",
          "1.4"
        ],
        "approved": false
      },
      {
        "code": "A-05",
        "text": "Allowable soil bearing 150 kPa, friction 0.45.",
        "value": "150 kPa",
        "sensitivity": "high",
        "affects": [
          "1.4"
        ],
        "approved": false
      }
    ],
    "gaps": [
      {
        "code": "G-01",
        "question": "Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?",
        "class": "blocking",
        "discipline": "systems",
        "why": "The current architecture is a placeholder; nothing can be approved until the invention is described.",
        "affects": [
          "1"
        ],
        "resolved": false
      },
      {
        "code": "G-02",
        "question": "Custom hexagonal laminates, or standard certified modules in hexagonal frames?",
        "class": "blocking",
        "discipline": "electrical_power",
        "why": "Custom laminates need their own IEC 61215/61730 qualification — a major cost and schedule item.",
        "affects": [
          "1.1.1"
        ],
        "resolved": false
      },
      {
        "code": "G-03",
        "question": "Site, permitting authority and grid connection.",
        "class": "assumable",
        "discipline": "compliance",
        "why": "Sets wind/snow loads and electrical code.",
        "proposed_assumption": "A-03, A-04",
        "affects": [
          "1.3",
          "1.4",
          "1.5"
        ],
        "resolved": false
      },
      {
        "code": "G-04",
        "question": "Geotechnical data.",
        "class": "assumable",
        "discipline": "civil_geotech",
        "why": "Foundation size.",
        "proposed_assumption": "A-05",
        "affects": [
          "1.4"
        ],
        "resolved": false
      }
    ],
    "load_cases": [
      {
        "code": "LC-01",
        "name": "Peak production",
        "kind": "operating",
        "description": "1000 W/m², 25 °C ambient, tracking",
        "values": {}
      },
      {
        "code": "LC-02",
        "name": "Stow, design wind",
        "kind": "extreme",
        "description": "50 m/s on the stowed cluster",
        "values": {
          "v": {
            "value": 50,
            "unit": "m/s",
            "basis": "assumed"
          }
        }
      },
      {
        "code": "LC-03",
        "name": "Snow on stowed cluster",
        "kind": "extreme",
        "description": "Ground snow load per site",
        "values": {}
      }
    ],
    "risks": [
      {
        "code": "R-01",
        "title": "Tracking gain does not pay for the tracker",
        "cause": "Module prices are low; trackers add cost and maintenance",
        "effect": "Worse cost per kWh than fixed tilt",
        "likelihood": 3,
        "severity": 4,
        "mitigation": "Cost-per-kWh comparison with fixed tilt and single-axis",
        "owner": "cost"
      },
      {
        "code": "R-02",
        "title": "Custom laminate certification",
        "cause": "Hexagonal format is not a stock module",
        "effect": "Cost and 6–12 month delay",
        "likelihood": 4,
        "severity": 4,
        "mitigation": "Prefer certified modules in hex frames",
        "owner": "compliance"
      },
      {
        "code": "R-03",
        "title": "Self-shading inside the cluster",
        "cause": "Cells around a hub shade each other at low sun",
        "effect": "Lower yield, hot spots",
        "likelihood": 3,
        "severity": 3,
        "mitigation": "Shading model; MLPE per cell",
        "owner": "electrical_power"
      },
      {
        "code": "R-04",
        "title": "Wind overturning on a single mast",
        "cause": "Large sail area on one support",
        "effect": "Mast or foundation failure",
        "likelihood": 2,
        "severity": 5,
        "mitigation": "Stow logic with redundancy; structural review",
        "owner": "structural"
      }
    ],
    "basis": {
      "area": {
        "value": 10,
        "unit": "m²",
        "basis": "assumed",
        "source": "A-02"
      },
      "eta": {
        "value": 21.5,
        "unit": "%",
        "basis": "supplier_data",
        "source": "A-02: typical 2026 mono modules"
      },
      "psh": {
        "value": 6,
        "unit": "h",
        "basis": "assumed",
        "source": "A-03 (tracked)"
      },
      "psh_fixed": {
        "value": 4.5,
        "unit": "h",
        "basis": "assumed",
        "source": "A-03 (fixed tilt)"
      },
      "v_design": {
        "value": 50,
        "unit": "m/s",
        "basis": "assumed",
        "source": "A-04"
      },
      "rho": {
        "value": 1.225,
        "unit": "kg/m³",
        "basis": "standard"
      },
      "stow_area": {
        "value": 3.6,
        "unit": "m²",
        "basis": "assumed",
        "source": "A-04: 30 % of 12 m² gross"
      },
      "cd_stow": {
        "value": 1.3,
        "unit": "",
        "basis": "assumed",
        "source": "A-04"
      },
      "hub_height": {
        "value": 3,
        "unit": "m",
        "basis": "assumed"
      },
      "mast_d": {
        "value": 0.27,
        "unit": "m",
        "basis": "assumed"
      },
      "mast_h": {
        "value": 3,
        "unit": "m",
        "basis": "assumed"
      },
      "dead_load": {
        "value": 8,
        "unit": "kN",
        "basis": "assumed"
      },
      "footing_b": {
        "value": 2,
        "unit": "m",
        "basis": "assumed"
      },
      "q_allow": {
        "value": 150,
        "unit": "kPa",
        "basis": "assumed",
        "source": "A-05"
      },
      "soil_mu": {
        "value": 0.45,
        "unit": "",
        "basis": "assumed",
        "source": "A-05"
      },
      "reserve_target": {
        "value": 0.2,
        "unit": "",
        "basis": "assumed"
      }
    }
  },
  "calculations": [
    {
      "key": "CALC-01",
      "title": "Cluster output at peak sun, tracked annual energy",
      "fingerprint": "0cee1857255295",
      "informative": false,
      "method": "solar.pv_output",
      "version": "1.0.0",
      "inputs": {
        "area": 10,
        "eta": 21.5,
        "g": 1000,
        "conc": 1,
        "t_amb": 25,
        "noct": 45,
        "gamma": -0.35,
        "losses": 14,
        "psh": 6
      },
      "outputs": [
        {
          "key": "t_cell",
          "label": "Cell temperature",
          "value": 56.25,
          "unit": "°C"
        },
        {
          "key": "p_stc",
          "label": "Rated DC power at STC",
          "value": 2.15,
          "unit": "kW"
        },
        {
          "key": "p_dc",
          "label": "DC output at this condition",
          "value": 1.9148,
          "unit": "kW"
        },
        {
          "key": "p_ac",
          "label": "AC output at this condition",
          "value": 1.6468,
          "unit": "kW"
        },
        {
          "key": "e_year",
          "label": "Annual energy (estimate)",
          "value": 3606.4,
          "unit": "kWh"
        },
        {
          "key": "specific_yield",
          "label": "Specific yield",
          "value": 1677.4,
          "unit": "kWh"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-02",
      "title": "Same modules on a fixed-tilt baseline",
      "fingerprint": "053e6d4aff82c6",
      "informative": false,
      "method": "solar.pv_output",
      "version": "1.0.0",
      "inputs": {
        "area": 10,
        "eta": 21.5,
        "g": 1000,
        "conc": 1,
        "t_amb": 25,
        "noct": 45,
        "gamma": -0.35,
        "losses": 14,
        "psh": 4.5
      },
      "outputs": [
        {
          "key": "t_cell",
          "label": "Cell temperature",
          "value": 56.25,
          "unit": "°C"
        },
        {
          "key": "p_stc",
          "label": "Rated DC power at STC",
          "value": 2.15,
          "unit": "kW"
        },
        {
          "key": "p_dc",
          "label": "DC output at this condition",
          "value": 1.9148,
          "unit": "kW"
        },
        {
          "key": "p_ac",
          "label": "AC output at this condition",
          "value": 1.6468,
          "unit": "kW"
        },
        {
          "key": "e_year",
          "label": "Annual energy (estimate)",
          "value": 2704.8,
          "unit": "kWh"
        },
        {
          "key": "specific_yield",
          "label": "Specific yield",
          "value": 1258.1,
          "unit": "kWh"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-03",
      "title": "Design wind on the stowed cluster and mast",
      "fingerprint": "16b533aedcbd89",
      "informative": false,
      "method": "wind.thrust",
      "version": "1.0.0",
      "inputs": {
        "v": 50,
        "rho": 1.225,
        "area": 3.6,
        "ct": 1.3,
        "h_rotor": 3,
        "tower_d": 0.27,
        "tower_h": 3,
        "cd_tower": 1.2
      },
      "outputs": [
        {
          "key": "q",
          "label": "Velocity pressure",
          "value": 1531.3,
          "unit": "Pa"
        },
        {
          "key": "f_rotor",
          "label": "Rotor force",
          "value": 7.1663,
          "unit": "kN"
        },
        {
          "key": "f_tower",
          "label": "Tower force",
          "value": 1.4884,
          "unit": "kN"
        },
        {
          "key": "h_total",
          "label": "Total base shear",
          "value": 8.6546,
          "unit": "kN"
        },
        {
          "key": "m_base",
          "label": "Overturning moment at base",
          "value": 23.731,
          "unit": "kN·m"
        }
      ],
      "checks": [],
      "warnings": [
        "Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-04",
      "title": "Mast pad: overturning, sliding, bearing",
      "fingerprint": "0ed9952e96ba91",
      "informative": false,
      "method": "foundation.spread_footing",
      "version": "1.0.0",
      "inputs": {
        "b": 2,
        "depth": 0.7,
        "cover": 0.4,
        "gamma_c": 23.6,
        "gamma_s": 18,
        "v": 8,
        "h": 8.6546,
        "m": 23.731,
        "q_allow": 150,
        "mu": 0.45,
        "fs_ot": 1.5,
        "fs_sl": 1.5
      },
      "outputs": [
        {
          "key": "w_footing",
          "label": "Footing weight",
          "value": 66.08,
          "unit": "kN"
        },
        {
          "key": "w_soil",
          "label": "Soil cover weight",
          "value": 28.8,
          "unit": "kN"
        },
        {
          "key": "w_total",
          "label": "Total stabilising vertical load",
          "value": 102.88,
          "unit": "kN"
        },
        {
          "key": "m_ot",
          "label": "Overturning moment at base",
          "value": 33.251,
          "unit": "kN·m"
        },
        {
          "key": "e",
          "label": "Eccentricity",
          "value": 0.3232,
          "unit": "m"
        },
        {
          "key": "q_max",
          "label": "Peak soil pressure",
          "value": 50.658,
          "unit": "kPa"
        },
        {
          "key": "q_min",
          "label": "Minimum soil pressure",
          "value": 0.7817,
          "unit": "kPa"
        },
        {
          "key": "concrete",
          "label": "Concrete volume",
          "value": 2.8,
          "unit": "m³"
        }
      ],
      "checks": [
        {
          "name": "overturning",
          "capacity": 102.88,
          "demand": 33.251,
          "unit": "kN·m",
          "ratio": 3.09,
          "required_ratio": 1.5,
          "basis": "FS ≥ 1.5 (common practice; code combinations govern)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "sliding",
          "capacity": 46.296,
          "demand": 8.6546,
          "unit": "kN",
          "ratio": 5.35,
          "required_ratio": 1.5,
          "basis": "FS ≥ 1.5 (common practice; code combinations govern)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "soil bearing",
          "capacity": 150,
          "demand": 50.658,
          "unit": "kPa",
          "ratio": 2.96,
          "required_ratio": 1,
          "basis": "allowable bearing pressure from the geotechnical engineer (already includes its factor)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-05",
      "title": "Mast anchor rods (steel strength)",
      "fingerprint": "0aa17aea154a5d",
      "informative": false,
      "method": "anchor.bolt_circle",
      "version": "1.0.0",
      "inputs": {
        "n": 8,
        "dbc": 0.45,
        "size": "M20",
        "grade": "F1554-55",
        "m": 23.731,
        "p": 7.2,
        "h": 8.6546
      },
      "outputs": [
        {
          "key": "t_max",
          "label": "Peak anchor tension",
          "value": 25.468,
          "unit": "kN"
        },
        {
          "key": "v_each",
          "label": "Shear per anchor",
          "value": 1.0818,
          "unit": "kN"
        },
        {
          "key": "phi_n",
          "label": "Design tensile strength φNsa",
          "value": 94.919,
          "unit": "kN"
        },
        {
          "key": "phi_v",
          "label": "Design shear strength φVsa",
          "value": 49.358,
          "unit": "kN"
        },
        {
          "key": "interaction",
          "label": "Tension–shear interaction",
          "value": 0.29023,
          "unit": ""
        }
      ],
      "checks": [
        {
          "name": "anchor tension (steel)",
          "capacity": 94.919,
          "demand": 25.468,
          "unit": "kN",
          "ratio": 3.73,
          "required_ratio": 1.2,
          "basis": "LRFD φ factors applied; plus project reserve 20 %",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "anchor shear (steel)",
          "capacity": 49.358,
          "demand": 1.0818,
          "unit": "kN",
          "ratio": 45.6,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "tension–shear interaction (≤ 1.2)",
          "capacity": 1.2,
          "demand": 0.29023,
          "unit": "",
          "ratio": 4.13,
          "required_ratio": 1,
          "basis": "ACI 318 §17.8 interaction",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)"
      ],
      "verdict": "warn",
      "errors": []
    }
  ],
  "traceability": [
    {
      "code": "REQ-PERF-001",
      "text": "Rated DC output of the prototype cluster.",
      "critical": true,
      "verification": "test",
      "nodes": [
        "1",
        "1.1"
      ],
      "runs": [
        {
          "key": "CALC-01",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-PERF-002",
      "text": "Annual energy shall be compared with a fixed-tilt array using the same modules.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1"
      ],
      "runs": [
        {
          "key": "CALC-01",
          "verdict": "pass"
        },
        {
          "key": "CALC-02",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the design wind in stow position.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.3"
      ],
      "runs": [
        {
          "key": "CALC-03",
          "verdict": "warn"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "Stow automatically above a set wind speed and on loss of power.",
      "critical": true,
      "verification": "test",
      "nodes": [
        "1.2"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-STR-001",
      "text": "The mast foundation shall resist overturning and sliding within allowable soil bearing.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.4"
      ],
      "runs": [
        {
          "key": "CALC-04",
          "verdict": "warn"
        },
        {
          "key": "CALC-05",
          "verdict": "warn"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-MOD-001",
      "text": "Cells shall be added or replaced without disturbing neighbouring cells.",
      "critical": false,
      "verification": "demonstration",
      "nodes": [
        "1.1"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-REG-001",
      "text": "Modules, racking and inverter listed for the jurisdiction.",
      "critical": false,
      "verification": "inspection",
      "nodes": [
        "1.5"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-LIFE-001",
      "text": "Design life.",
      "critical": false,
      "verification": "analysis",
      "nodes": [
        "1"
      ],
      "runs": [],
      "status": "none"
    }
  ],
  "findings": [
    {
      "code": "F-001",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-01: Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?",
      "refs": [
        "G-01",
        "1"
      ]
    },
    {
      "code": "F-002",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?",
      "refs": [
        "G-02",
        "1.1.1"
      ]
    },
    {
      "code": "F-003",
      "severity": "warning",
      "class": "assumable",
      "message": "G-03: Site, permitting authority and grid connection.",
      "refs": [
        "G-03",
        "1.3",
        "1.4",
        "1.5"
      ]
    },
    {
      "code": "F-004",
      "severity": "warning",
      "class": "assumable",
      "message": "G-04: Geotechnical data.",
      "refs": [
        "G-04",
        "1.4"
      ]
    },
    {
      "code": "F-006",
      "severity": "warning",
      "class": "completeness",
      "message": "1.2.4 Tracker controller with wind-stow has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.2.4"
      ]
    },
    {
      "code": "F-007",
      "severity": "warning",
      "class": "completeness",
      "message": "No seals in the product structure. Every machine needs them somewhere — add them or state why not.",
      "refs": []
    },
    {
      "code": "F-008",
      "severity": "warning",
      "class": "completeness",
      "message": "No lubrication in the product structure. Every machine needs them somewhere — add them or state why not.",
      "refs": []
    },
    {
      "code": "F-009",
      "severity": "warning",
      "class": "completeness",
      "message": "No sensors / instrumentation in the product structure. Every machine needs them somewhere — add them or state why not.",
      "refs": []
    },
    {
      "code": "F-010",
      "severity": "warning",
      "class": "completeness",
      "message": "No service access in the product structure. Every machine needs them somewhere — add them or state why not.",
      "refs": []
    },
    {
      "code": "F-016",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-01 not yet approved: PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast.",
      "refs": [
        "A-01",
        "1"
      ]
    },
    {
      "code": "F-017",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-02 not yet approved: Active cell area 10 m² at 21.5 % module efficiency.",
      "refs": [
        "A-02",
        "1.1"
      ]
    },
    {
      "code": "F-018",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-03 not yet approved: Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0.",
      "refs": [
        "A-03",
        "1.1"
      ]
    },
    {
      "code": "F-019",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-05 not yet approved: Allowable soil bearing 150 kPa, friction 0.45.",
      "refs": [
        "A-05",
        "1.4"
      ]
    },
    {
      "code": "F-005",
      "severity": "info",
      "class": "completeness",
      "message": "1.1.1 PV laminates cut / built to hexagonal format: make, buy or reuse not decided.",
      "refs": [
        "1.1.1"
      ]
    },
    {
      "code": "F-011",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-01 (structural) not yet defined: Cell frame to hub connector: wind and snow load path, bonding.",
      "refs": [
        "I-01",
        "1.1.2",
        "1.1.3"
      ]
    },
    {
      "code": "F-012",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-02 (structural) not yet defined: Cluster hub to tracking head bearing.",
      "refs": [
        "I-02",
        "1.1.3",
        "1.2.3"
      ]
    },
    {
      "code": "F-013",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-03 (signal) not yet defined: Controller to slew drive and actuator.",
      "refs": [
        "I-03",
        "1.2.4",
        "1.2.1"
      ]
    },
    {
      "code": "F-014",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-04 (structural) not yet defined: Mast base plate to anchor rods.",
      "refs": [
        "I-04",
        "1.3.2",
        "1.4.2"
      ]
    },
    {
      "code": "F-015",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-05 (electrical) not yet defined: Cell DC outputs to inverters.",
      "refs": [
        "I-05",
        "1.1.4",
        "1.5.1"
      ]
    },
    {
      "code": "F-020",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-01 rests on assumed values: area, psh.",
      "refs": [
        "CALC-01"
      ]
    },
    {
      "code": "F-021",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-02 rests on assumed values: area, psh_fixed.",
      "refs": [
        "CALC-02"
      ]
    },
    {
      "code": "F-022",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-03 rests on assumed values: v_design, stow_area, cd_stow, hub_height, mast_d, mast_h.",
      "refs": [
        "CALC-03"
      ]
    },
    {
      "code": "F-023",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-04 rests on assumed values: footing_b, dead_load, q_allow, soil_mu.",
      "refs": [
        "CALC-04"
      ]
    },
    {
      "code": "F-024",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-05: anchor shear (steel) has 45.6× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-05",
        "1.4.2"
      ]
    },
    {
      "code": "F-025",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-05: tension–shear interaction (≤ 1.2) has 4.13× capacity against 1 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-05",
        "1.4.2"
      ]
    },
    {
      "code": "F-026",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-05 rests on assumed values: dead_load.",
      "refs": [
        "CALC-05"
      ]
    },
    {
      "code": "F-027",
      "severity": "info",
      "class": "evidence",
      "message": "16 referenced standard(s) not yet acquired or edition-checked: IEC 61215, IEC 61730 / UL 61730, UL 3703 / UL 2703, ISO 898-1, NFPA 70 (NEC) Art. 690, 694, 705, ISO 13849-1/-2, ISO 281, ISO 76, IEC 61000 series, ANSI/AISC 360, ASCE/SEI 7, ACI 318, International Building Code (as adopted locally), ASTM F1554, UL 1741, IEEE 1547.",
      "refs": [
        "iec-61215",
        "iec-61730",
        "ul-3703",
        "iso-898-1",
        "nfpa-70",
        "iso-13849",
        "iso-281",
        "iso-76",
        "iec-61000",
        "aisc-360",
        "asce-7",
        "aci-318",
        "ibc",
        "astm-f1554",
        "ul-1741",
        "ieee-1547"
      ]
    },
    {
      "code": "F-028",
      "severity": "info",
      "class": "completeness",
      "message": "1 electronics item(s) to hand off to VX Design: Tracker controller with wind-stow.",
      "refs": [
        "1.2.4"
      ]
    }
  ],
  "plan": [
    {
      "inputs": [
        "Inventor interview",
        "Patent / design documents"
      ],
      "depends_on": [],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S1-BRIEF",
      "stage": "S1",
      "title": "Concept brief and open-question register",
      "discipline": "systems",
      "deliverable": "Concept brief v1 with open-question register",
      "method": "Interview the inventor; import patents, sketches, CAD and prior studies",
      "role": "Systems engineer",
      "hours": 6,
      "acceptance": "Brief states function, environment, scale, budget and constraints; every unknown is in the register"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-01",
      "stage": "S1",
      "title": "Resolve G-01: Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?",
      "discipline": "systems",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Systems engineer",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1.1.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-02",
      "stage": "S1",
      "title": "Resolve G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?",
      "discipline": "electrical_power",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Electrical engineer",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF",
        "S1-G-01",
        "S1-G-02"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002",
        "REQ-SAFE-001",
        "REQ-SAFE-002",
        "REQ-STR-001",
        "REQ-MOD-001",
        "REQ-REG-001",
        "REQ-LIFE-001"
      ],
      "approval_gate": true,
      "risk": "medium",
      "key": "S2-REQ",
      "stage": "S2",
      "title": "Requirements baseline",
      "discipline": "systems",
      "deliverable": "Requirements baseline (8 requirements) with measurable targets",
      "method": "Derive measurable targets, jurisdiction, design life and safety requirements from the brief",
      "role": "Systems engineer",
      "hours": 8,
      "acceptance": "Every requirement measurable and verifiable; inventor approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S2-REQ"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "medium",
      "key": "S2-CONCEPTS",
      "stage": "S2",
      "title": "Alternative concepts and baselines",
      "discipline": "systems",
      "deliverable": "Concept comparison incl. conventional baselines; schematic diagrams",
      "method": "Generate alternatives; score transparently; include the conventional and direct-drive (or fixed) baselines",
      "role": "Systems engineer",
      "hours": 12,
      "acceptance": "Selected concept recorded with reasons"
    },
    {
      "inputs": [],
      "depends_on": [
        "S2-CONCEPTS"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S3-DECOMP",
      "stage": "S3",
      "title": "System decomposition review",
      "discipline": "systems",
      "deliverable": "Product structure (19 items) with functions and interfaces",
      "method": "Recursive decomposition to testable work packages; check functions ↔ subsystems; review gap findings",
      "role": "Systems engineer",
      "hours": 8,
      "acceptance": "No orphan function or requirement; every part has discipline, analyses, standards and acceptance test"
    },
    {
      "inputs": [
        "IEC 61215",
        "IEC 61730 / UL 61730",
        "UL 3703 / UL 2703",
        "ISO 898-1",
        "NFPA 70 (NEC) Art. 690, 694, 705",
        "ISO 13849-1/-2",
        "ISO 281",
        "ISO 76",
        "IEC 61000 series",
        "ANSI/AISC 360",
        "ASCE/SEI 7",
        "ACI 318",
        "International Building Code (as adopted locally)",
        "ASTM F1554",
        "UL 1741",
        "IEEE 1547"
      ],
      "depends_on": [
        "S3-DECOMP"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S3-STANDARDS",
      "stage": "S3",
      "title": "Standards applicability matrix",
      "discipline": "compliance",
      "deliverable": "Applicability matrix for 16 standards; acquisition tasks for missing documents",
      "method": "Resolve jurisdiction, edition and amendments; map clauses to requirements (registry workflow)",
      "role": "Compliance engineer",
      "hours": 16,
      "acceptance": "Each standard: edition identified, acquired or purchase task raised, clauses mapped"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-DECOMP",
        "S3-STANDARDS"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S3-PLAN",
      "stage": "S3",
      "title": "Approve the development plan",
      "discipline": "systems",
      "deliverable": "Approved development plan and staffing",
      "method": "Review this task graph, estimates and gates",
      "role": "Project lead",
      "hours": 3,
      "acceptance": "Inventor / owner approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-001",
        "REQ-MOD-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.1",
      "stage": "S4",
      "title": "Preliminary design: Hexagonal PV cells",
      "discipline": "electrical_power",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Electrical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.2"
      ],
      "requirements": [
        "REQ-SAFE-002"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.2",
      "stage": "S4",
      "title": "Preliminary design: Tracking head",
      "discipline": "mechanical",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Mechanical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.3"
      ],
      "requirements": [
        "REQ-SAFE-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.3",
      "stage": "S4",
      "title": "Preliminary design: Mast",
      "discipline": "structural",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Structural engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.4"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.4",
      "stage": "S4",
      "title": "Preliminary design: Foundation",
      "discipline": "civil_geotech",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Civil / geotechnical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.5"
      ],
      "requirements": [
        "REQ-REG-001"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-DES-1.5",
      "stage": "S4",
      "title": "Preliminary design: Power conversion and interconnection",
      "discipline": "electrical_power",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Electrical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.1.1",
      "stage": "S4",
      "title": "Detail: PV laminates cut / built to hexagonal format",
      "discipline": "electrical_power",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (si-mono-perc); confirm against governing specification",
      "role": "Electrical engineer",
      "hours": 10,
      "acceptance": "Custom-format laminates need their own IEC 61215 qualification — or use standard rectangular modules in hex frames"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.1.2",
      "stage": "S4",
      "title": "Detail: Hexagonal cell frames",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (al-6063-t6); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Frame carries 2400 Pa wind / 5400 Pa snow test loads"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.1.3",
      "stage": "S4",
      "title": "Detail: Cell-to-hub quick connectors",
      "discipline": "mechanical",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (ss-316); confirm against governing specification",
      "role": "Mechanical engineer",
      "hours": 10,
      "acceptance": "Cell swap without tools in ≤ 30 min; bonding path maintained"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.1.4",
      "stage": "S4",
      "title": "Source: DC wiring, connectors and bonding",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2"
      ],
      "nodes": [
        "1.2.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.2.1",
      "stage": "S4",
      "title": "Source: Azimuth slew drive",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2"
      ],
      "nodes": [
        "1.2.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.2.2",
      "stage": "S4",
      "title": "Source: Elevation actuator",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2"
      ],
      "nodes": [
        "1.2.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.2.3",
      "stage": "S4",
      "title": "Source: Hub slewing bearing",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.3.1",
      "stage": "S4",
      "title": "Detail: Steel mast tube",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a500-c); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Member checks by structural engineer"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.3.2",
      "stage": "S4",
      "title": "Detail: Mast base plate and flange bolts",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a36); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Plate and bolt checks"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4"
      ],
      "nodes": [
        "1.4.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.4.1",
      "stage": "S4",
      "title": "Detail: Reinforced-concrete pad",
      "discipline": "civil_geotech",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (concrete-28); confirm against governing specification",
      "role": "Civil / geotechnical engineer",
      "hours": 10,
      "acceptance": "FS ≥ 1.5; bearing within allowable"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4"
      ],
      "nodes": [
        "1.4.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.4.2",
      "stage": "S4",
      "title": "Source: Anchor rods",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5"
      ],
      "nodes": [
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.5.1",
      "stage": "S4",
      "title": "Source: Microinverters or string inverter with MLPE",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-PART-1.1.1",
        "S4-PART-1.1.2",
        "S4-PART-1.1.3",
        "S4-SRC-1.1.4",
        "S4-SRC-1.2.1",
        "S4-SRC-1.2.2",
        "S4-SRC-1.2.3",
        "S4-PART-1.3.1",
        "S4-PART-1.3.2",
        "S4-PART-1.4.1",
        "S4-SRC-1.4.2",
        "S4-SRC-1.5.1"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-BOM",
      "stage": "S4",
      "title": "Preliminary BOM",
      "discipline": "sourcing",
      "deliverable": "Part-level BOM with make/buy, quantities, cost ranges and lead times",
      "method": "Roll up the product structure",
      "role": "Buyer",
      "hours": 4,
      "acceptance": "Every part has quantity, make/buy and a cost range with its basis"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-01",
      "stage": "S5",
      "title": "Cluster output at peak sun, tracked annual energy",
      "discipline": "electrical_power",
      "deliverable": "Photovoltaic array output and annual yield — result with checks and validity",
      "method": "Deterministic method solar.pv_output v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Electrical engineer",
      "hours": 3,
      "calc": "CALC-01",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-002"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-02",
      "stage": "S5",
      "title": "Same modules on a fixed-tilt baseline",
      "discipline": "electrical_power",
      "deliverable": "Photovoltaic array output and annual yield — result with checks and validity",
      "method": "Deterministic method solar.pv_output v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Electrical engineer",
      "hours": 3,
      "calc": "CALC-02",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3"
      ],
      "requirements": [
        "REQ-SAFE-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-03",
      "stage": "S5",
      "title": "Design wind on the stowed cluster and mast",
      "discipline": "structural",
      "deliverable": "Rotor and tower wind thrust, base reactions — result with checks and validity",
      "method": "Deterministic method wind.thrust v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Structural engineer",
      "hours": 3,
      "calc": "CALC-03",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4",
        "S5-CALC-03"
      ],
      "nodes": [
        "1.4.1"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-04",
      "stage": "S5",
      "title": "Mast pad: overturning, sliding, bearing",
      "discipline": "civil_geotech",
      "deliverable": "Square spread footing: overturning, sliding and soil bearing — result with checks and validity",
      "method": "Deterministic method foundation.spread_footing v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Civil / geotechnical engineer",
      "hours": 3,
      "calc": "CALC-04",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4",
        "S5-CALC-03"
      ],
      "nodes": [
        "1.4.2"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-05",
      "stage": "S5",
      "title": "Mast anchor rods (steel strength)",
      "discipline": "structural",
      "deliverable": "Anchor bolts on a bolt circle: tension and shear (steel strength) — result with checks and validity",
      "method": "Deterministic method anchor.bolt_circle v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Structural engineer",
      "hours": 3,
      "calc": "CALC-05",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-CALC-01",
        "S5-CALC-02",
        "S5-CALC-03",
        "S5-CALC-04",
        "S5-CALC-05"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002",
        "REQ-SAFE-001",
        "REQ-SAFE-002",
        "REQ-STR-001"
      ],
      "approval_gate": true,
      "risk": "high",
      "key": "S5-FEAS",
      "stage": "S5",
      "title": "Feasibility report",
      "discipline": "systems",
      "deliverable": "Feasibility verdict with best/base/worst cases, unknowns, validation plan and cost to resolve uncertainty",
      "method": "Classify per spec §06 from actual results; compare with baselines",
      "role": "Systems engineer",
      "hours": 10,
      "acceptance": "Verdict traceable to results; independent review requested for safety-critical items"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.1.2",
        "1.1.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-01",
      "stage": "S6",
      "title": "Define interface I-01: Cell frame to hub connector: wind and snow load path, bonding",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.1.3",
        "1.2.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-02",
      "stage": "S6",
      "title": "Define interface I-02: Cluster hub to tracking head bearing",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.2.4",
        "1.2.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-03",
      "stage": "S6",
      "title": "Define interface I-03: Controller to slew drive and actuator",
      "discipline": "controls",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.3.2",
        "1.4.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-04",
      "stage": "S6",
      "title": "Define interface I-04: Mast base plate to anchor rods",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.1.4",
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-05",
      "stage": "S6",
      "title": "Define interface I-05: Cell DC outputs to inverters",
      "discipline": "controls",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS",
        "S6-I-01",
        "S6-I-02",
        "S6-I-03",
        "S6-I-04",
        "S6-I-05"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S6-TRADE",
      "stage": "S6",
      "title": "Optimization trade study",
      "discipline": "systems",
      "deliverable": "Recommended configuration (mass, cost, energy, reliability) with Pareto comparison",
      "method": "Vary geometry, materials, ratios and control thresholds; re-run impacted calculations",
      "role": "Systems engineer",
      "hours": 20,
      "acceptance": "Mandatory constraints hold in the recommended configuration"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-BOM",
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S7-COST",
      "stage": "S7",
      "title": "Cost model",
      "discipline": "cost",
      "deliverable": "NRE vs recurring cost; prototype, pilot and production scenarios; contingency",
      "method": "Roll up BOM, labour, tooling, testing, certification",
      "role": "Project controls",
      "hours": 8,
      "acceptance": "Quotes vs estimates labelled; currency, date, exclusions stated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S7-SCOPES",
      "stage": "S7",
      "title": "Partner scopes",
      "discipline": "systems",
      "deliverable": "Scopes of work for: Electrical power, Structural, Electronics / PCB (VX Design), Civil and geotechnical",
      "method": "Discipline handoff packages (spec §07)",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Each scope lists inputs, deliverables, standards and sign-off"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-COST",
        "S7-SCOPES"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S7-ROADMAP",
      "stage": "S7",
      "title": "Development roadmap and funding milestones",
      "discipline": "cost",
      "deliverable": "Schedule, budget per milestone, funding asks, contingencies",
      "method": "Sequence prototype → test → pilot; tie funding tranches to evidence",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Owner approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [
        "1.2.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S8-VXD",
      "stage": "S8",
      "title": "VX Design electronics handoff",
      "discipline": "electronics",
      "deliverable": "Structured VX Design intake package",
      "method": "Export power budget, interfaces, environment, safety and EMC requirements",
      "role": "Systems engineer",
      "hours": 4,
      "acceptance": "VX Design accepts the intake without open questions"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-COST"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S8-RFQ",
      "stage": "S8",
      "title": "RFQ packages",
      "discipline": "sourcing",
      "deliverable": "Drawings, specs, quantities, tolerances, inspection and delivery requirements per supplier",
      "method": "Assemble from part records",
      "role": "Buyer",
      "hours": 8,
      "acceptance": "Owner approves before any external disclosure"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-SAFE-002",
        "REQ-MOD-001",
        "REQ-REG-001"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S8-TESTPLAN",
      "stage": "S8",
      "title": "Prototype instrumentation and test plan",
      "discipline": "testing",
      "deliverable": "Test procedures for 4 requirements verified by test/inspection/demonstration",
      "method": "One procedure per requirement; instrumentation list; pass criteria",
      "role": "Test engineer",
      "hours": 8,
      "acceptance": "Every test-verified requirement has a procedure and pass criterion"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-ROADMAP",
        "S8-RFQ",
        "S8-TESTPLAN",
        "S8-VXD"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S8-PACKAGE",
      "stage": "S8",
      "title": "Funding-ready preliminary package",
      "discipline": "systems",
      "deliverable": "Brief, requirements, structure, BOM, calcs, feasibility, risks, costs, roadmap — marked preliminary",
      "method": "Assemble and export; no certification or construction-readiness claims",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Reviewer approval status shown on every document"
    }
  ],
  "cost": {
    "currency": "USD",
    "date": "2026-11-25",
    "bom": [
      {
        "id": "1.1.1",
        "name": "PV laminates cut / built to hexagonal format",
        "qty": 7,
        "make_buy": "tbd",
        "low": 1400,
        "high": 4200,
        "basis": "assumed"
      },
      {
        "id": "1.1.2",
        "name": "Hexagonal cell frames",
        "qty": 7,
        "make_buy": "make",
        "low": 700,
        "high": 2100,
        "basis": "assumed"
      },
      {
        "id": "1.1.3",
        "name": "Cell-to-hub quick connectors",
        "qty": 7,
        "make_buy": "make",
        "low": 200,
        "high": 600,
        "basis": "assumed"
      },
      {
        "id": "1.1.4",
        "name": "DC wiring, connectors and bonding",
        "qty": 1,
        "make_buy": "buy",
        "low": 150,
        "high": 500,
        "basis": "assumed"
      },
      {
        "id": "1.2.1",
        "name": "Azimuth slew drive",
        "qty": 1,
        "make_buy": "buy",
        "low": 500,
        "high": 1500,
        "basis": "assumed"
      },
      {
        "id": "1.2.2",
        "name": "Elevation actuator",
        "qty": 1,
        "make_buy": "buy",
        "low": 250,
        "high": 800,
        "basis": "assumed"
      },
      {
        "id": "1.2.3",
        "name": "Hub slewing bearing",
        "qty": 1,
        "make_buy": "buy",
        "low": 400,
        "high": 1200,
        "basis": "assumed"
      },
      {
        "id": "1.2.4",
        "name": "Tracker controller with wind-stow",
        "qty": 1,
        "make_buy": "make",
        "low": 300,
        "high": 1200,
        "basis": "assumed"
      },
      {
        "id": "1.3.1",
        "name": "Steel mast tube",
        "qty": 1,
        "make_buy": "make",
        "low": 600,
        "high": 1800,
        "basis": "assumed"
      },
      {
        "id": "1.3.2",
        "name": "Mast base plate and flange bolts",
        "qty": 1,
        "make_buy": "make",
        "low": 250,
        "high": 700,
        "basis": "assumed"
      },
      {
        "id": "1.4.1",
        "name": "Reinforced-concrete pad",
        "qty": 1,
        "make_buy": "make",
        "low": 1500,
        "high": 4000,
        "basis": "assumed"
      },
      {
        "id": "1.4.2",
        "name": "Anchor rods",
        "qty": 8,
        "make_buy": "buy",
        "low": 250,
        "high": 700,
        "basis": "assumed"
      },
      {
        "id": "1.5.1",
        "name": "Microinverters or string inverter with MLPE",
        "qty": 1,
        "make_buy": "buy",
        "low": 600,
        "high": 1800,
        "basis": "assumed"
      }
    ],
    "lines": [
      {
        "label": "Parts and materials (BOM roll-up)",
        "low": 7100,
        "high": 21100,
        "kind": "recurring",
        "basis": "estimates — not quotes"
      },
      {
        "label": "Assembly, inspection and freight (15 % of parts)",
        "low": 1065,
        "high": 3165,
        "kind": "recurring",
        "basis": "rule of thumb"
      },
      {
        "label": "Engineering (329 h from the plan at $120/h, ±30 %)",
        "low": 27636,
        "high": 51324,
        "kind": "nre",
        "basis": "plan estimate"
      },
      {
        "label": "Prototype testing and instrumentation",
        "low": 3550,
        "high": 21100,
        "kind": "nre",
        "basis": "allowance: 50–100 % of one unit's parts"
      },
      {
        "label": "Independent specialist review (structural, geotechnical, mechanical)",
        "low": 4000,
        "high": 15000,
        "kind": "nre",
        "basis": "allowance"
      },
      {
        "label": "Permits and site work",
        "low": 1500,
        "high": 8000,
        "kind": "nre",
        "basis": "allowance; jurisdiction-dependent"
      },
      {
        "label": "Certification path (pre-assessment; full certification excluded)",
        "low": 5000,
        "high": 25000,
        "kind": "nre",
        "basis": "allowance"
      }
    ],
    "nre": {
      "low": 52107.5,
      "high": 150530
    },
    "unit": {
      "low": 8164.999999999999,
      "high": 24264.999999999996
    },
    "scenarios": [
      {
        "name": "Prototype",
        "units": 1,
        "unit_low": 8164.999999999999,
        "unit_high": 24264.999999999996,
        "total_low": 60272.5,
        "total_high": 174795
      },
      {
        "name": "Pilot",
        "units": 10,
        "unit_low": 4758.728584998305,
        "unit_high": 14142.137062459751,
        "total_low": 47587.285849983055,
        "total_high": 141421.3706245975
      },
      {
        "name": "Production",
        "units": 100,
        "unit_low": 2773.4841084727464,
        "unit_high": 8242.326012503514,
        "total_low": 277348.41084727464,
        "total_high": 824232.6012503514
      }
    ],
    "assumptions": [
      "Engineering rate $120/h",
      "Contingency 25 % on NRE",
      "Learning curve 85 % per doubling (applied to unit cost)",
      "Part costs are estimates unless marked supplier_data"
    ],
    "exclusions": [
      "Full certification testing",
      "Land, grid-connection fees",
      "Taxes and duties",
      "Patent prosecution",
      "Operating and maintenance costs (reported separately once a duty cycle is agreed)"
    ]
  }
}