  "schema": "vx-design-intake/1",
  "source": {
    "product": "VX Inventor",
    "project": "Solar Hive",
    "exported": "2026-11-25T06:31:05.969Z"
  },
  "status": "preliminary",
  "summary": "Solar Hive: Modular hexagonal solar cells clustered on a tracking mast (placeholder reading — import the invention's description).",
  "boards": [
    {
      "ref": "1.2.4",
      "name": "Tracker controller with wind-stow",
      "function": "Sun-position tracking ±1°; stow on anemometer or power loss",
      "notes": "Routed to VX Design"
    }
  ],
  "interfaces": [
    {
      "id": "I-03",
      "kind": "signal",
      "between": [
        "Tracker controller with wind-stow",
        "Azimuth slew drive"
      ],
      "description": "Controller to slew drive and actuator",
      "defined": false
    },
    {
      "id": "I-05",
      "kind": "electrical",
      "between": [
        "DC wiring, connectors and bonding",
        "Microinverters or string inverter with MLPE"
      ],
      "description": "Cell DC outputs to inverters",
      "defined": false
    }
  ],
  "power_budget": [
    {
      "source": "CALC-01 DC output at this condition",
      "value": 1.9148,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-01 AC output at this condition",
      "value": 1.6468,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 DC output at this condition",
      "value": 1.9148,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 AC output at this condition",
      "value": 1.6468,
      "unit": "kW",
      "basis": "calculated from assumptions"
    }
  ],
  "environment": [
    "Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code."
  ],
  "safety": [
    "REQ-SAFE-001: Survive the design wind in stow position. (ASCE 7 basic wind speed for the site (assumed 50 m/s))",
    "REQ-SAFE-002: Stow automatically above a set wind speed and on loss of power. (stow ≤ 90 s from trigger)",
    "REQ-STR-001: The mast foundation shall resist overturning and sliding within allowable soil bearing. (FS ≥ 1.5; q ≤ q_allow)"
  ],
  "standards": [
    {
      "id": "ISO 13849-1/-2",
      "title": "Safety of machinery — Safety-related parts of control systems"
    },
    {
      "id": "IEC 61000 series",
      "title": "Electromagnetic compatibility"
    },
    {
      "id": "IEC 60529",
      "title": "Degrees of protection provided by enclosures (IP code)"
    },
    {
      "id": "IEC 60204-1",
      "title": "Safety of machinery — Electrical equipment of machines"
    }
  ],
  "requirements": [
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the design wind in stow position.",
      "target": "ASCE 7 basic wind speed for the site (assumed 50 m/s)"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "Stow automatically above a set wind speed and on loss of power.",
      "target": "stow ≤ 90 s from trigger"
    },
    {
      "code": "REQ-STR-001",
      "text": "The mast foundation shall resist overturning and sliding within allowable soil bearing.",
      "target": "FS ≥ 1.5; q ≤ q_allow"
    },
    {
      "code": "REQ-REG-001",
      "text": "Modules, racking and inverter listed for the jurisdiction.",
      "target": "IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690"
    }
  ],
  "open_questions": []
}