  "schema": "vx-inventor-package/1",
  "status": "preliminary — not certified, not construction-ready",
  "exported": "2026-11-25T06:31:00.046Z",
  "revision": null,
  "verdict": {
    "class": "conditional",
    "reasons": [
      "All 15 mandatory calculations pass on the stated assumptions."
    ],
    "conditions": [
      "G-01: Import the patent / design documents for the vertical transmission and the staged clutch arrangement.",
      "G-02: Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?",
      "G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?",
      "G-08: Prototype budget and the funding target.",
      "A-01 must be confirmed: Rotor is a 3-blade H-type vertical-axis rotor, 3 m diameter × 4 m high, on top of the tower.",
      "A-02 must be confirmed: Rotor power coefficient Cp = 0.30 at tip-speed ratio 3 (mid-range of published H-rotor tests).",
      "A-03 must be confirmed: Site wind: annual mean 6 m/s at rotor height, Rayleigh distribution (no site data yet).",
      "A-05 must be confirmed: Three 1.5 kW permanent-magnet generators behind a 6.5:1 speed-up stage.",
      "A-07 must be confirmed: Allowable soil bearing 150 kPa, friction 0.45 (no geotechnical report).",
      "A-11 must be confirmed: Clutch: a centrifugal shoe clutch whose engagement is held off or released by an electromagnet, so a controller can set the engagement threshold by power.",
      "CALC-10: Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer",
      "CALC-11: Basic life only: run the maker's calculator (a_ISO, lubrication, contamination) before selection",
      "CALC-12: Lewis screening only: rate to AGMA 2001 / ISO 6336 (bending and contact) before selection",
      "CALC-15: eccentricity 0.87 m exceeds B/6 = 0.58 m: part of the base lifts off the soil (allowed by some codes for wind, not for sustained loads)",
      "CALC-16: Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)"
    ],
    "counts": {
      "runs": 15,
      "pass": 10,
      "warn": 5,
      "fail": 0,
      "invalid": 0,
      "blocking_gaps": 4,
      "unapproved_high": 6
    },
    "label": "Conditional feasibility"
  },
  "record": {
    "key": "vertical-wind-turbine",
    "name": "Vertical-transmission wind turbine",
    "tagline": "A wind rotor drives a vertical shaft down the tower to staged, clutch-engaged generators at ground level.",
    "summary": "The rotor's torque travels down a vertical transmission shaft inside the tower to a ground-level generator house. There, a speed-up gear stage feeds a bank of generators that are engaged one at a time by magnetically controlled centrifugal clutches as the available power rises, so each engaged generator runs near its efficient load point, and every heavy, serviceable part sits at ground level instead of at the top of the tower.",
    "status_note": "Preliminary reference design built from stated assumptions. Import the patent and design documents to replace assumptions A-01, A-05 and A-11 before the architecture is locked.",
    "brief": {
      "function": "Generate electricity from wind with high part-load efficiency and ground-level maintenance of the drivetrain.",
      "environment": "Outdoor, rural/suburban site, −20 to +45 °C, corrosivity C3, IEC small-wind class III (assumed).",
      "scale": "Small wind: ≈ 12 m² swept area, ≈ 3–4 kW rated (prototype scale); architecture intended to scale.",
      "budget": "Not yet stated (gap G-10).",
      "constraints": [
        "Generators, clutches and gearbox serviceable from the ground",
        "No performance claim until supported by test",
        "Conventional drivetrain and direct-drive are the baselines"
      ]
    },
    "requirements": [
      {
        "code": "REQ-PERF-001",
        "kind": "performance",
        "text": "Rated electrical output at 12 m/s hub wind speed.",
        "target": "≥ 3.0 kW electrical at 12 m/s",
        "priority": "must",
        "verification": "test",
        "critical": true
      },
      {
        "code": "REQ-PERF-002",
        "kind": "performance",
        "text": "Begin producing power at low wind speed.",
        "target": "cut-in ≤ 3.5 m/s",
        "priority": "must",
        "verification": "test",
        "critical": false
      },
      {
        "code": "REQ-PERF-003",
        "kind": "performance",
        "text": "Staged generator engagement shall raise part-load conversion efficiency compared with one generator of the same total rating.",
        "target": "≥ +5 % electrical output at 6 m/s",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-PERF-004",
        "kind": "performance",
        "text": "Annual energy production shall be reported against conventional geared and direct-drive baselines with the same rotor.",
        "target": "AEP at 6 m/s Rayleigh, with uncertainty",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-SAFE-001",
        "kind": "safety",
        "text": "Survive the 50-year extreme wind parked without structural failure.",
        "target": "Ve50 = 52.5 m/s (IEC 61400-2 class III)",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-SAFE-002",
        "kind": "safety",
        "text": "A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid.",
        "target": "stop from 1.3× rated speed; PL c or better (ISO 13849)",
        "priority": "must",
        "verification": "test",
        "critical": true
      },
      {
        "code": "REQ-SAFE-003",
        "kind": "safety",
        "text": "All rotating parts accessible at ground level shall be guarded.",
        "target": "ISO 12100 / ISO 13857 distances",
        "priority": "must",
        "verification": "inspection",
        "critical": false
      },
      {
        "code": "REQ-INT-001",
        "kind": "interface",
        "text": "The vertical shaft shall run clear of its bending critical speeds.",
        "target": "critical / max running speed ≥ 1.25",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-STR-001",
        "kind": "safety",
        "text": "The foundation shall resist overturning and sliding and stay within allowable soil bearing.",
        "target": "FS ≥ 1.5 overturning and sliding; q ≤ q_allow",
        "priority": "must",
        "verification": "analysis",
        "critical": true
      },
      {
        "code": "REQ-LIFE-001",
        "kind": "life",
        "text": "Design life.",
        "target": "20 years",
        "priority": "must",
        "verification": "analysis",
        "critical": false
      },
      {
        "code": "REQ-LIFE-002",
        "kind": "life",
        "text": "Rolling bearings shall reach their rating life without replacement.",
        "target": "L10 ≥ 100 000 h",
        "priority": "should",
        "verification": "analysis",
        "critical": false
      },
      {
        "code": "REQ-MAINT-001",
        "kind": "maintainability",
        "text": "Generators, clutches, brake and gearbox shall be replaceable from ground level without climbing or a crane.",
        "target": "≤ 4 h per generator swap, 2 people",
        "priority": "must",
        "verification": "demonstration",
        "critical": false
      },
      {
        "code": "REQ-ENV-001",
        "kind": "environmental",
        "text": "Operating environment.",
        "target": "−20 to +45 °C; ISO 12944 C3; enclosures IP54 min",
        "priority": "must",
        "verification": "analysis",
        "critical": false
      },
      {
        "code": "REQ-ENV-002",
        "kind": "environmental",
        "text": "Noise at the nearest dwelling.",
        "target": "≤ local limit (typ. 45 dB(A) at night)",
        "priority": "should",
        "verification": "test",
        "critical": false
      },
      {
        "code": "REQ-REG-001",
        "kind": "regulatory",
        "text": "Follow a recognised small-wind certification path.",
        "target": "IEC 61400-2 or ANSI/ACP 101-1",
        "priority": "should",
        "verification": "inspection",
        "critical": false
      },
      {
        "code": "REQ-REG-002",
        "kind": "regulatory",
        "text": "Grid-connected operation shall use listed interconnection equipment.",
        "target": "UL 1741 / IEEE 1547",
        "priority": "must",
        "verification": "inspection",
        "critical": false
      },
      {
        "code": "REQ-COST-001",
        "kind": "cost",
        "text": "Prototype build cost and levelised cost of energy shall be estimated against the baselines.",
        "target": "costed range with exclusions",
        "priority": "must",
        "verification": "analysis",
        "critical": false
      }
    ],
    "functions": [
      {
        "code": "F1",
        "name": "Capture wind energy",
        "modes": [
          "start-up",
          "power production",
          "parked"
        ],
        "subsystem": "1.1"
      },
      {
        "code": "F2",
        "name": "Carry rotor loads into the tower",
        "modes": [
          "all"
        ],
        "subsystem": "1.2"
      },
      {
        "code": "F3",
        "name": "Transmit torque down to ground level",
        "modes": [
          "power production"
        ],
        "subsystem": "1.3"
      },
      {
        "code": "F4",
        "name": "Raise speed for the generators",
        "modes": [
          "power production"
        ],
        "subsystem": "1.4"
      },
      {
        "code": "F5",
        "name": "Engage generators in stages by available power",
        "modes": [
          "start-up",
          "rising wind",
          "falling wind"
        ],
        "subsystem": "1.5"
      },
      {
        "code": "F6",
        "name": "Convert to electricity",
        "modes": [
          "power production"
        ],
        "subsystem": "1.5"
      },
      {
        "code": "F7",
        "name": "Limit speed and stop safely",
        "modes": [
          "overspeed",
          "loss of load",
          "maintenance"
        ],
        "subsystem": "1.6"
      },
      {
        "code": "F8",
        "name": "Condition and deliver power",
        "modes": [
          "grid-tied",
          "battery"
        ],
        "subsystem": "1.7"
      },
      {
        "code": "F9",
        "name": "Support and resist all loads",
        "modes": [
          "all"
        ],
        "subsystem": "1.8"
      },
      {
        "code": "F10",
        "name": "Anchor to the ground",
        "modes": [
          "all"
        ],
        "subsystem": "1.9"
      },
      {
        "code": "F11",
        "name": "Protect people and parts, allow service",
        "modes": [
          "all"
        ],
        "subsystem": "1.10"
      }
    ],
    "nodes": [
      {
        "id": "1",
        "parent": null,
        "level": "system",
        "name": "Vertical-transmission wind turbine",
        "discipline": "systems",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [],
        "analyses": [],
        "requirements": [
          "REQ-PERF-001",
          "REQ-PERF-004",
          "REQ-LIFE-001",
          "REQ-REG-001"
        ],
        "acceptance": "Feasibility package reviewed and approved"
      },
      {
        "id": "1.1",
        "parent": "1",
        "level": "subsystem",
        "name": "Rotor",
        "discipline": "aero_fluids",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iec-61400-2",
          "iec-61400-12-1"
        ],
        "analyses": [
          "wind.rotor_power",
          "wind.annual_energy"
        ],
        "requirements": [
          "REQ-PERF-001",
          "REQ-PERF-002"
        ],
        "function": "F1"
      },
      {
        "id": "1.1.1",
        "parent": "1.1",
        "level": "part",
        "name": "Blades (H-rotor, pultruded aerofoil)",
        "discipline": "aero_fluids",
        "quantity": 3,
        "make_buy": "make",
        "standards": [
          "iec-61400-2"
        ],
        "analyses": [
          "wind.rotor_power"
        ],
        "requirements": [],
        "material": "gfrp-pultruded",
        "cost": {
          "low": 900,
          "high": 2400,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 8,
        "acceptance": "Blade static test to 1.35 × extreme load; mass and balance within tolerance"
      },
      {
        "id": "1.1.2",
        "parent": "1.1",
        "level": "part",
        "name": "Blade struts / arms",
        "discipline": "structural",
        "quantity": 6,
        "make_buy": "make",
        "standards": [
          "aisc-360"
        ],
        "analyses": [],
        "requirements": [],
        "material": "al-6061-t6",
        "cost": {
          "low": 600,
          "high": 1500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Fatigue check at 2P cyclic load; joint test"
      },
      {
        "id": "1.1.3",
        "parent": "1.1",
        "level": "assembly",
        "name": "Rotor hub",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aws-d1-1"
        ],
        "analyses": [],
        "requirements": [],
        "material": "astm-a572-50",
        "cost": {
          "low": 500,
          "high": 1400,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Weld inspection; bolt pattern to drawing"
      },
      {
        "id": "1.1.4",
        "parent": "1.1",
        "level": "part",
        "name": "Blade and strut fasteners",
        "discipline": "mechanical",
        "quantity": 36,
        "make_buy": "buy",
        "standards": [
          "iso-898-1",
          "vdi-2230"
        ],
        "analyses": [
          "bolt.joint"
        ],
        "requirements": [],
        "component": "fst-bolt",
        "material": "ss-316",
        "cost": {
          "low": 80,
          "high": 200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Torque-tension verified; locking method for vibration"
      },
      {
        "id": "1.2",
        "parent": "1",
        "level": "subsystem",
        "name": "Top bearing and rotor support",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iso-281",
          "iso-76"
        ],
        "analyses": [
          "bearing.life"
        ],
        "requirements": [
          "REQ-LIFE-002"
        ],
        "function": "F2"
      },
      {
        "id": "1.2.1",
        "parent": "1.2",
        "level": "part",
        "name": "Top radial bearing (spherical roller)",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-281",
          "iso-76"
        ],
        "analyses": [
          "bearing.life"
        ],
        "requirements": [],
        "component": "brg-srb",
        "cost": {
          "low": 150,
          "high": 450,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 4,
        "acceptance": "L10 ≥ 100 000 h; s0 ≥ 2 at extreme load"
      },
      {
        "id": "1.2.2",
        "parent": "1.2",
        "level": "part",
        "name": "Thrust bearing carrying rotor and shaft weight",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-281"
        ],
        "analyses": [
          "bearing.life"
        ],
        "requirements": [],
        "component": "brg-sab",
        "cost": {
          "low": 200,
          "high": 600,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "L10 ≥ 100 000 h under weight + vertical aero load"
      },
      {
        "id": "1.2.3",
        "parent": "1.2",
        "level": "assembly",
        "name": "Bearing housing, seals and lubrication",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iso-286"
        ],
        "analyses": [],
        "requirements": [],
        "material": "di-65-45-12",
        "component": "seal-lip",
        "cost": {
          "low": 300,
          "high": 900,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "IP55 seal; relubrication access from the tower top platform"
      },
      {
        "id": "1.3",
        "parent": "1",
        "level": "subsystem",
        "name": "Vertical transmission shaft",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "din-743",
          "iso-21940"
        ],
        "analyses": [
          "shaft.fatigue",
          "shaft.critical_speed"
        ],
        "requirements": [
          "REQ-INT-001"
        ],
        "function": "F3"
      },
      {
        "id": "1.3.1",
        "parent": "1.3",
        "level": "part",
        "name": "Shaft segments",
        "discipline": "mechanical",
        "quantity": 3,
        "make_buy": "make",
        "standards": [
          "iso-286",
          "din-743"
        ],
        "analyses": [
          "shaft.fatigue",
          "shaft.critical_speed"
        ],
        "requirements": [],
        "material": "aisi-4140-qt",
        "component": "shaft-solid",
        "cost": {
          "low": 900,
          "high": 2200,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 5,
        "acceptance": "Fatigue reserve ≥ target; straightness ≤ 0.1 mm/m; balance G6.3"
      },
      {
        "id": "1.3.2",
        "parent": "1.3",
        "level": "part",
        "name": "Segment couplings (disc type)",
        "discipline": "mechanical",
        "quantity": 2,
        "make_buy": "buy",
        "standards": [
          "iso-21940"
        ],
        "analyses": [],
        "requirements": [],
        "component": "cpl-disc",
        "cost": {
          "low": 400,
          "high": 1200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Rated torque ≥ 2 × rated shaft torque; misalignment within rating"
      },
      {
        "id": "1.3.3",
        "parent": "1.3",
        "level": "part",
        "name": "Intermediate steady bearings",
        "discipline": "mechanical",
        "quantity": 2,
        "make_buy": "buy",
        "standards": [
          "iso-281"
        ],
        "analyses": [
          "bearing.life",
          "shaft.critical_speed"
        ],
        "requirements": [],
        "component": "brg-dgbb",
        "cost": {
          "low": 120,
          "high": 400,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Spacing keeps critical-speed separation ≥ 1.25"
      },
      {
        "id": "1.3.4",
        "parent": "1.3",
        "level": "part",
        "name": "Steady-bearing brackets in tower",
        "discipline": "structural",
        "quantity": 2,
        "make_buy": "make",
        "standards": [
          "aws-d1-1"
        ],
        "analyses": [],
        "requirements": [],
        "material": "astm-a36",
        "cost": {
          "low": 150,
          "high": 400,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Bracket stiffness ≥ 10 × bearing radial stiffness requirement"
      },
      {
        "id": "1.4",
        "parent": "1",
        "level": "subsystem",
        "name": "Ground-level gear stage",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "agma-2001",
          "iso-6336",
          "agma-6006"
        ],
        "analyses": [
          "gear.lewis_bending"
        ],
        "requirements": [],
        "function": "F4"
      },
      {
        "id": "1.4.1",
        "parent": "1.4",
        "level": "assembly",
        "name": "Speed-up gearbox (planetary or helical)",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "agma-6006",
          "iso-6336"
        ],
        "analyses": [
          "gear.lewis_bending"
        ],
        "requirements": [],
        "component": "gbx-planetary",
        "cost": {
          "low": 1200,
          "high": 3500,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 10,
        "acceptance": "Rated ≥ 1.5 × rated torque (service factor); efficiency ≥ 96 %"
      },
      {
        "id": "1.4.2",
        "parent": "1.4",
        "level": "assembly",
        "name": "Power take-off to generator branches",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "agma-2001"
        ],
        "analyses": [
          "gear.lewis_bending"
        ],
        "requirements": [],
        "component": "gear-helical",
        "cost": {
          "low": 800,
          "high": 2500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "All branches driven at equal speed; branch disconnect possible for service",
        "notes": "Layout depends on the patent (G-01): common gear with pinions, or stacked generators on one shaft"
      },
      {
        "id": "1.4.3",
        "parent": "1.4",
        "level": "part",
        "name": "Gearbox lubricant",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "material": "oil-iso-vg220",
        "cost": {
          "low": 60,
          "high": 150,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Viscosity grade suits −20 °C start"
      },
      {
        "id": "1.5",
        "parent": "1",
        "level": "subsystem",
        "name": "Staged generator bank",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iec-60034"
        ],
        "analyses": [
          "drivetrain.staged_generators",
          "clutch.engagement",
          "energy.balance"
        ],
        "requirements": [
          "REQ-PERF-003"
        ],
        "function": "F5"
      },
      {
        "id": "1.5.1",
        "parent": "1.5",
        "level": "part",
        "name": "Magnetically controlled centrifugal clutches",
        "discipline": "mechanical",
        "quantity": 3,
        "make_buy": "make",
        "standards": [],
        "analyses": [
          "clutch.engagement"
        ],
        "requirements": [],
        "component": "clu-centrifugal",
        "material": "ndfeb-n42",
        "cost": {
          "low": 900,
          "high": 3000,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 8,
        "acceptance": "Engages and releases at set thresholds with hysteresis; slip heat within plate rating at 30 engagements/h",
        "notes": "Inventor's mechanism (G-06): how the magnet controls the shoes sets the engagement law"
      },
      {
        "id": "1.5.2",
        "parent": "1.5",
        "level": "part",
        "name": "Permanent-magnet generators 1.5 kW",
        "discipline": "electrical_power",
        "quantity": 3,
        "make_buy": "buy",
        "standards": [
          "iec-60034"
        ],
        "analyses": [
          "drivetrain.staged_generators"
        ],
        "requirements": [],
        "component": "gen-pmsg-radial",
        "cost": {
          "low": 1200,
          "high": 3000,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 6,
        "acceptance": "Measured efficiency map from 10–100 % load"
      },
      {
        "id": "1.5.3",
        "parent": "1.5",
        "level": "part",
        "name": "Generator couplings (jaw)",
        "discipline": "mechanical",
        "quantity": 3,
        "make_buy": "buy",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "component": "cpl-jaw",
        "cost": {
          "low": 120,
          "high": 300,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Torque rating ≥ 2 × generator rated torque"
      },
      {
        "id": "1.5.4",
        "parent": "1.5",
        "level": "assembly",
        "name": "Clutch magnet drivers and engagement controller",
        "discipline": "electronics",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iec-60204-1",
          "iec-61000"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 400,
          "high": 1500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Implements engagement thresholds and hysteresis; fails to a safe state",
        "notes": "Routed to VX Design through the electronics handoff"
      },
      {
        "id": "1.6",
        "parent": "1",
        "level": "subsystem",
        "name": "Braking and overspeed protection",
        "discipline": "controls",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iso-13849",
          "iso-12100"
        ],
        "analyses": [],
        "requirements": [
          "REQ-SAFE-002"
        ],
        "function": "F7"
      },
      {
        "id": "1.6.1",
        "parent": "1.6",
        "level": "part",
        "name": "Spring-applied fail-safe brake",
        "discipline": "mechanical",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-13849"
        ],
        "analyses": [],
        "requirements": [],
        "component": "brk-spring-em",
        "cost": {
          "low": 400,
          "high": 1200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Stops rotor from 1.3 × rated speed; holds at Ve50 parked torque"
      },
      {
        "id": "1.6.2",
        "parent": "1.6",
        "level": "part",
        "name": "Redundant overspeed sensing",
        "discipline": "controls",
        "quantity": 2,
        "make_buy": "buy",
        "standards": [
          "iso-13849"
        ],
        "analyses": [],
        "requirements": [],
        "component": "sns-speed",
        "cost": {
          "low": 150,
          "high": 500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Two independent channels; trip verified by test"
      },
      {
        "id": "1.7",
        "parent": "1",
        "level": "subsystem",
        "name": "Power electronics, controls and electrical",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "ul-1741",
          "ieee-1547",
          "nfpa-70",
          "iec-60204-1",
          "iec-60529"
        ],
        "analyses": [],
        "requirements": [
          "REQ-REG-002"
        ],
        "function": "F8"
      },
      {
        "id": "1.7.1",
        "parent": "1.7",
        "level": "assembly",
        "name": "Supervisory controller",
        "discipline": "electronics",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iec-61000",
          "iso-13849"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 500,
          "high": 2000,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "State machine verified in simulation and on the test rig",
        "notes": "Routed to VX Design"
      },
      {
        "id": "1.7.2",
        "parent": "1.7",
        "level": "assembly",
        "name": "Rectifiers, DC bus and listed hybrid inverter",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "ul-1741",
          "ieee-1547"
        ],
        "analyses": [],
        "requirements": [],
        "component": "pwr-rectifier-inv",
        "cost": {
          "low": 1500,
          "high": 4000,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Listed equipment; MPPT tuned to the staged bank"
      },
      {
        "id": "1.7.3",
        "parent": "1.7",
        "level": "part",
        "name": "Dump load / diversion resistor",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 100,
          "high": 300,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Absorbs rated power continuously on loss of grid"
      },
      {
        "id": "1.7.4",
        "parent": "1.7",
        "level": "assembly",
        "name": "Sensors: anemometer, shaft speed/torque, vibration, temperatures",
        "discipline": "controls",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "iso-20816"
        ],
        "analyses": [],
        "requirements": [],
        "component": "sns-speed",
        "cost": {
          "low": 600,
          "high": 2500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Instrumentation list complete for prototype test plan"
      },
      {
        "id": "1.7.5",
        "parent": "1.7",
        "level": "assembly",
        "name": "Enclosures, disconnects, wiring and earthing",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "nfpa-70",
          "iec-60529"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 500,
          "high": 1500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "IP54+; NEC 694 disconnects; bonding verified"
      },
      {
        "id": "1.8",
        "parent": "1",
        "level": "subsystem",
        "name": "Tower",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "aisc-360",
          "asce-7",
          "aws-d1-1"
        ],
        "analyses": [
          "wind.thrust",
          "bolt.joint"
        ],
        "requirements": [
          "REQ-SAFE-001"
        ],
        "function": "F9"
      },
      {
        "id": "1.8.1",
        "parent": "1.8",
        "level": "assembly",
        "name": "Tubular steel tower, flanged sections",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aisc-360",
          "asce-7"
        ],
        "analyses": [
          "wind.thrust"
        ],
        "requirements": [],
        "material": "astm-a500-c",
        "component": "str-tower-tube",
        "cost": {
          "low": 2500,
          "high": 6000,
          "currency": "USD",
          "basis": "assumed"
        },
        "lead_time_weeks": 8,
        "acceptance": "Member and connection checks by structural engineer; tower frequency clear of 1P/2P/3P"
      },
      {
        "id": "1.8.2",
        "parent": "1.8",
        "level": "part",
        "name": "Tower base flange bolts (M24, class 10.9)",
        "discipline": "structural",
        "quantity": 16,
        "make_buy": "buy",
        "standards": [
          "iso-898-1",
          "vdi-2230"
        ],
        "analyses": [
          "bolt.joint"
        ],
        "requirements": [],
        "component": "fst-bolt",
        "cost": {
          "low": 100,
          "high": 300,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Preload verified; fatigue check"
      },
      {
        "id": "1.8.3",
        "parent": "1.8",
        "level": "part",
        "name": "Tower base plate",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aisc-360",
          "aws-d1-1"
        ],
        "analyses": [],
        "requirements": [],
        "material": "astm-a36",
        "cost": {
          "low": 300,
          "high": 900,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Plate bending and weld checks (AISC DG1)"
      },
      {
        "id": "1.8.4",
        "parent": "1.8",
        "level": "assembly",
        "name": "Service access: hatch, climbing / tower-lowering provision",
        "discipline": "structural",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "osha-1910"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 400,
          "high": 2500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Top bearing reachable with fall protection, or tower tilts down"
      },
      {
        "id": "1.9",
        "parent": "1",
        "level": "subsystem",
        "name": "Foundation",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "aci-318",
          "asce-7",
          "ibc"
        ],
        "analyses": [
          "foundation.spread_footing",
          "anchor.bolt_circle"
        ],
        "requirements": [
          "REQ-STR-001"
        ],
        "function": "F10"
      },
      {
        "id": "1.9.1",
        "parent": "1.9",
        "level": "part",
        "name": "Reinforced-concrete spread footing",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "aci-318"
        ],
        "analyses": [
          "foundation.spread_footing"
        ],
        "requirements": [],
        "material": "concrete-28",
        "component": "str-footing",
        "cost": {
          "low": 2500,
          "high": 6000,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "FS ≥ 1.5 overturning/sliding; bearing ≤ allowable from the geotechnical report"
      },
      {
        "id": "1.9.2",
        "parent": "1.9",
        "level": "part",
        "name": "Reinforcement",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "astm-a615",
          "aci-318"
        ],
        "analyses": [],
        "requirements": [],
        "material": "rebar-a615-60",
        "cost": {
          "low": 400,
          "high": 1200,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Flexure and punching shear by structural engineer"
      },
      {
        "id": "1.9.3",
        "parent": "1.9",
        "level": "part",
        "name": "Anchor rods (M30, F1554 Gr 55) and setting template",
        "discipline": "structural",
        "quantity": 12,
        "make_buy": "buy",
        "standards": [
          "astm-f1554",
          "aci-318"
        ],
        "analyses": [
          "anchor.bolt_circle"
        ],
        "requirements": [],
        "component": "fst-anchor",
        "material": "anchor-f1554-55",
        "cost": {
          "low": 300,
          "high": 900,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Steel and concrete-breakout strength checked (ACI 318 ch. 17)"
      },
      {
        "id": "1.9.4",
        "parent": "1.9",
        "level": "part",
        "name": "Base-plate grout",
        "discipline": "civil_geotech",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "material": "grout-c1107",
        "cost": {
          "low": 50,
          "high": 150,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Full bearing under base plate"
      },
      {
        "id": "1.9.5",
        "parent": "1.9",
        "level": "part",
        "name": "Earthing electrode and lightning protection",
        "discipline": "electrical_power",
        "quantity": 1,
        "make_buy": "buy",
        "standards": [
          "nfpa-70"
        ],
        "analyses": [],
        "requirements": [],
        "cost": {
          "low": 200,
          "high": 800,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Earth resistance ≤ 25 Ω (or as specified)"
      },
      {
        "id": "1.10",
        "parent": "1",
        "level": "subsystem",
        "name": "Generator house, guards and service provisions",
        "discipline": "manufacturing",
        "quantity": 1,
        "make_buy": "tbd",
        "standards": [
          "iso-12100",
          "iec-60529"
        ],
        "analyses": [],
        "requirements": [
          "REQ-SAFE-003",
          "REQ-MAINT-001",
          "REQ-ENV-001"
        ],
        "function": "F11"
      },
      {
        "id": "1.10.1",
        "parent": "1.10",
        "level": "assembly",
        "name": "Weatherproof generator house",
        "discipline": "manufacturing",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iec-60529"
        ],
        "analyses": [],
        "requirements": [],
        "material": "al-5083-h116",
        "cost": {
          "low": 1000,
          "high": 3500,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "IP54; ventilation keeps generators within rating at 45 °C"
      },
      {
        "id": "1.10.2",
        "parent": "1.10",
        "level": "part",
        "name": "Guards on rotating parts",
        "discipline": "manufacturing",
        "quantity": 1,
        "make_buy": "make",
        "standards": [
          "iso-12100"
        ],
        "analyses": [],
        "requirements": [],
        "material": "astm-a36",
        "cost": {
          "low": 200,
          "high": 700,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Interlocked access; ISO 13857 distances"
      },
      {
        "id": "1.10.3",
        "parent": "1.10",
        "level": "part",
        "name": "Lifting points and generator slide rails",
        "discipline": "manufacturing",
        "quantity": 1,
        "make_buy": "make",
        "standards": [],
        "analyses": [],
        "requirements": [],
        "material": "astm-a36",
        "cost": {
          "low": 200,
          "high": 600,
          "currency": "USD",
          "basis": "assumed"
        },
        "acceptance": "Generator swap demonstrated in ≤ 4 h"
      }
    ],
    "interfaces": [
      {
        "id": "I-01",
        "a": "1.1.3",
        "b": "1.3.1",
        "kind": "rotational",
        "description": "Rotor hub to top shaft segment: torque, weight and rotor bending moment",
        "defined": false
      },
      {
        "id": "I-02",
        "a": "1.2",
        "b": "1.8.1",
        "kind": "structural",
        "description": "Top bearing housing to tower top: radial rotor loads and weight into the tower",
        "defined": false
      },
      {
        "id": "I-03",
        "a": "1.3.1",
        "b": "1.3.2",
        "kind": "rotational",
        "description": "Shaft segments joined by disc couplings",
        "defined": true
      },
      {
        "id": "I-04",
        "a": "1.3.3",
        "b": "1.3.4",
        "kind": "structural",
        "description": "Steady bearings to tower brackets: radial support only",
        "defined": false
      },
      {
        "id": "I-05",
        "a": "1.3.1",
        "b": "1.4.1",
        "kind": "rotational",
        "description": "Shaft bottom to gearbox input (coupling, axial float allowance for thermal growth of the long shaft)",
        "defined": false
      },
      {
        "id": "I-06",
        "a": "1.4.2",
        "b": "1.5.1",
        "kind": "rotational",
        "description": "Power take-off to each clutch",
        "defined": false
      },
      {
        "id": "I-07",
        "a": "1.5.1",
        "b": "1.5.2",
        "kind": "rotational",
        "description": "Clutch output to generator via jaw coupling",
        "defined": true
      },
      {
        "id": "I-08",
        "a": "1.5.4",
        "b": "1.5.1",
        "kind": "signal",
        "description": "Magnet driver command to each clutch; engagement state feedback",
        "defined": false
      },
      {
        "id": "I-09",
        "a": "1.5.2",
        "b": "1.7.2",
        "kind": "electrical",
        "description": "Generator AC to rectifiers / DC bus",
        "defined": false
      },
      {
        "id": "I-10",
        "a": "1.6.1",
        "b": "1.7.1",
        "kind": "signal",
        "description": "Brake release / apply and overspeed trip",
        "defined": false
      },
      {
        "id": "I-11",
        "a": "1.8.3",
        "b": "1.9.3",
        "kind": "structural",
        "description": "Base plate to anchor rods: tension, compression and shear",
        "defined": false
      },
      {
        "id": "I-12",
        "a": "1.9.1",
        "b": "1.9",
        "kind": "structural",
        "description": "Footing to soil: bearing pressure, sliding resistance",
        "defined": false
      },
      {
        "id": "I-13",
        "a": "1.10.1",
        "b": "1.5.2",
        "kind": "thermal",
        "description": "Generator and gearbox heat rejected from the house",
        "defined": false
      }
    ],
    "assumptions": [
      {
        "code": "A-01",
        "text": "Rotor is a 3-blade H-type vertical-axis rotor, 3 m diameter × 4 m high, on top of the tower.",
        "value": "D 3 m, H 4 m, A 12 m²",
        "sensitivity": "high",
        "affects": [
          "1.1",
          "1.2",
          "1.8",
          "1.9"
        ],
        "approved": false
      },
      {
        "code": "A-02",
        "text": "Rotor power coefficient Cp = 0.30 at tip-speed ratio 3 (mid-range of published H-rotor tests).",
        "value": "Cp 0.30, λ 3",
        "sensitivity": "high",
        "affects": [
          "1.1",
          "1.5"
        ],
        "approved": false
      },
      {
        "code": "A-03",
        "text": "Site wind: annual mean 6 m/s at rotor height, Rayleigh distribution (no site data yet).",
        "value": "6 m/s, k = 2",
        "sensitivity": "high",
        "affects": [
          "1.1"
        ],
        "approved": false
      },
      {
        "code": "A-04",
        "text": "IEC 61400-2 class III: Vref 37.5 m/s, 50-year extreme Ve50 = 52.5 m/s.",
        "value": "Ve50 52.5 m/s",
        "sensitivity": "medium",
        "affects": [
          "1.8",
          "1.9"
        ],
        "approved": false
      },
      {
        "code": "A-05",
        "text": "Three 1.5 kW permanent-magnet generators behind a 6.5:1 speed-up stage.",
        "value": "3 × 1.5 kW, 6.5:1",
        "sensitivity": "high",
        "affects": [
          "1.4",
          "1.5"
        ],
        "approved": false
      },
      {
        "code": "A-06",
        "text": "Generator losses: 10 % at rated, 35 % of that fixed (core, friction, windage).",
        "value": "η 0.90, fixed share 0.35",
        "sensitivity": "medium",
        "affects": [
          "1.5"
        ],
        "approved": false
      },
      {
        "code": "A-07",
        "text": "Allowable soil bearing 150 kPa, friction 0.45 (no geotechnical report).",
        "value": "150 kPa",
        "sensitivity": "high",
        "affects": [
          "1.9"
        ],
        "approved": false
      },
      {
        "code": "A-08",
        "text": "Rotor centre 10 m above grade; tower Ø 0.4 m × 8 m.",
        "value": "10 m",
        "sensitivity": "medium",
        "affects": [
          "1.3",
          "1.8",
          "1.9"
        ],
        "approved": false
      },
      {
        "code": "A-09",
        "text": "Shaft: solid Ø 60 mm AISI 4140 Q&T in three segments; torque ripple ±50 % of mean (2-blade-pass excitation of a VAWT).",
        "value": "Ø 60 mm, ripple 0.5",
        "sensitivity": "medium",
        "affects": [
          "1.3"
        ],
        "approved": false
      },
      {
        "code": "A-10",
        "text": "Parked rotor drag coefficient 1.2 on projected area (conservative).",
        "value": "C_T 1.2",
        "sensitivity": "medium",
        "affects": [
          "1.8",
          "1.9"
        ],
        "approved": false
      },
      {
        "code": "A-11",
        "text": "Clutch: a centrifugal shoe clutch whose engagement is held off or released by an electromagnet, so a controller can set the engagement threshold by power.",
        "sensitivity": "high",
        "affects": [
          "1.5.1",
          "1.5.4"
        ],
        "approved": false
      }
    ],
    "gaps": [
      {
        "code": "G-01",
        "question": "Import the patent / design documents for the vertical transmission and the staged clutch arrangement.",
        "class": "blocking",
        "discipline": "systems",
        "why": "Architecture (rotor type, power take-off layout, clutch mechanism) cannot be locked without them.",
        "affects": [
          "1",
          "1.4.2",
          "1.5.1"
        ],
        "resolved": false
      },
      {
        "code": "G-02",
        "question": "Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?",
        "class": "blocking",
        "discipline": "aero_fluids",
        "why": "Changes rotor loads, yaw system, top gearbox and every downstream calculation.",
        "proposed_assumption": "A-01: vertical-axis H-rotor",
        "affects": [
          "1.1",
          "1.2"
        ],
        "resolved": false
      },
      {
        "code": "G-03",
        "question": "Where will the prototype stand? Site wind data (or a nearby met station) and the permitting authority.",
        "class": "assumable",
        "discipline": "aero_fluids",
        "why": "AEP, extreme wind class and code jurisdiction depend on the site.",
        "proposed_assumption": "A-03 and A-04",
        "affects": [
          "1.1",
          "1.8",
          "1.9"
        ],
        "resolved": false
      },
      {
        "code": "G-04",
        "question": "Geotechnical report: allowable bearing, friction, frost depth, water table.",
        "class": "assumable",
        "discipline": "civil_geotech",
        "why": "Foundation size is sensitive to soil; preliminary sizing may assume, construction may not.",
        "proposed_assumption": "A-07: 150 kPa",
        "affects": [
          "1.9"
        ],
        "resolved": false
      },
      {
        "code": "G-05",
        "question": "How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?",
        "class": "blocking",
        "discipline": "mechanical",
        "why": "Sets the engagement law, slip energy and the controller design.",
        "proposed_assumption": "A-11",
        "affects": [
          "1.5.1",
          "1.5.4"
        ],
        "resolved": false
      },
      {
        "code": "G-06",
        "question": "Which generators: maker, rated speed, efficiency map, inertia?",
        "class": "assumable",
        "discipline": "electrical_power",
        "why": "Part-load efficiency is the whole case for staging; it must come from measured maps.",
        "proposed_assumption": "A-05, A-06",
        "affects": [
          "1.5.2"
        ],
        "resolved": false
      },
      {
        "code": "G-07",
        "question": "Grid-tied, battery-based or both?",
        "class": "deferred",
        "discipline": "electrical_power",
        "why": "Selects the inverter and the interconnection standards; does not change the mechanical design.",
        "affects": [
          "1.7.2"
        ],
        "resolved": false
      },
      {
        "code": "G-08",
        "question": "Prototype budget and the funding target.",
        "class": "blocking",
        "discipline": "cost",
        "why": "Scopes the prototype and test plan.",
        "affects": [
          "1"
        ],
        "resolved": false
      },
      {
        "code": "G-09",
        "question": "Local noise and setback limits.",
        "class": "deferred",
        "discipline": "compliance",
        "why": "Permitting condition, usually settled at site selection.",
        "affects": [
          "1.1"
        ],
        "resolved": false
      }
    ],
    "load_cases": [
      {
        "code": "LC-01",
        "name": "Rated operation",
        "kind": "operating",
        "description": "12 m/s, all generators engaged, rated torque",
        "values": {
          "v": {
            "value": 12,
            "unit": "m/s",
            "basis": "assumed"
          }
        }
      },
      {
        "code": "LC-02",
        "name": "Part load",
        "kind": "operating",
        "description": "6 m/s (site mean), staged engagement",
        "values": {
          "v": {
            "value": 6,
            "unit": "m/s",
            "basis": "assumed"
          }
        }
      },
      {
        "code": "LC-03",
        "name": "Parked extreme wind",
        "kind": "extreme",
        "description": "Ve50 = 52.5 m/s on the parked rotor and tower",
        "values": {
          "v": {
            "value": 52.5,
            "unit": "m/s",
            "basis": "standard",
            "source": "IEC 61400-2 class III"
          }
        }
      },
      {
        "code": "LC-04",
        "name": "Emergency stop from overspeed",
        "kind": "fault",
        "description": "Brake applied at 1.3 × rated speed, generators disengaged",
        "values": {}
      },
      {
        "code": "LC-05",
        "name": "Generator engagement transient",
        "kind": "operating",
        "description": "Clutch closes onto a stationary generator at shaft speed",
        "values": {}
      },
      {
        "code": "LC-06",
        "name": "Fatigue spectrum",
        "kind": "fatigue",
        "description": "20 years at the site distribution; 2P torque ripple on the shaft",
        "values": {}
      },
      {
        "code": "LC-07",
        "name": "Loss of grid / load rejection",
        "kind": "fault",
        "description": "Electrical load drops to zero at rated; dump load and brake respond",
        "values": {}
      }
    ],
    "risks": [
      {
        "code": "R-01",
        "title": "Staging gains less than claimed",
        "cause": "A single variable-speed generator with good MPPT is already efficient at part load",
        "effect": "Weak value case for funders",
        "likelihood": 3,
        "severity": 4,
        "mitigation": "Annual-energy comparison on measured generator maps; test both modes on one rig",
        "owner": "systems"
      },
      {
        "code": "R-02",
        "title": "Long-shaft whirl and torsional resonance",
        "cause": "Slender vertical shaft, couplings and tower flexibility",
        "effect": "Vibration, bearing and coupling failure",
        "likelihood": 3,
        "severity": 4,
        "mitigation": "Critical-speed and torsional analyses; steady bearings; rotordynamic review",
        "owner": "mechanical"
      },
      {
        "code": "R-03",
        "title": "Clutch wear and heat under gusty cycling",
        "cause": "Frequent engagements near threshold",
        "effect": "Short clutch life, fade",
        "likelihood": 4,
        "severity": 3,
        "mitigation": "Hysteresis and minimum-on timers; slip-energy budget; test",
        "owner": "mechanical"
      },
      {
        "code": "R-04",
        "title": "Blade–strut joint fatigue",
        "cause": "VAWT cyclic aerodynamic loads at 2P",
        "effect": "Blade loss",
        "likelihood": 4,
        "severity": 5,
        "mitigation": "Joint fatigue test; conservative detail; inspection interval",
        "owner": "structural"
      },
      {
        "code": "R-05",
        "title": "Gearbox bearing failures",
        "cause": "Small-wind gearboxes historically fail at bearings",
        "effect": "Downtime (mitigated by ground-level access)",
        "likelihood": 3,
        "severity": 3,
        "mitigation": "Service factor ≥ 1.5; condition monitoring; ground-level swap",
        "owner": "mechanical"
      },
      {
        "code": "R-06",
        "title": "Overspeed on loss of load",
        "cause": "Grid loss with all clutches released",
        "effect": "Runaway rotor",
        "likelihood": 2,
        "severity": 5,
        "mitigation": "Fail-safe spring brake, redundant speed sensing, dump load",
        "owner": "controls"
      },
      {
        "code": "R-07",
        "title": "Foundation under-design",
        "cause": "No soil data",
        "effect": "Tilt or overturning",
        "likelihood": 2,
        "severity": 5,
        "mitigation": "Geotechnical report before construction; conservative preliminary size",
        "owner": "civil_geotech"
      },
      {
        "code": "R-08",
        "title": "Cost per kWh above conventional small wind",
        "cause": "More generators, clutches and a long shaft",
        "effect": "No market",
        "likelihood": 3,
        "severity": 4,
        "mitigation": "Cost model vs baselines; design to cost",
        "owner": "cost"
      },
      {
        "code": "R-09",
        "title": "Certification time and cost",
        "cause": "IEC 61400-2 / ACP 101-1 testing",
        "effect": "Delay before sales",
        "likelihood": 3,
        "severity": 3,
        "mitigation": "Plan the test campaign early; pre-certification review",
        "owner": "compliance"
      },
      {
        "code": "R-10",
        "title": "Freedom to operate",
        "cause": "Prior art in staged generators and VAWT drivetrains",
        "effect": "IP dispute",
        "likelihood": 2,
        "severity": 4,
        "mitigation": "Patent search by counsel (patents are concept references, not proof)",
        "owner": "systems"
      }
    ],
    "basis": {
      "rotor_diameter": {
        "value": 3,
        "unit": "m",
        "basis": "assumed",
        "source": "A-01"
      },
      "rotor_height": {
        "value": 4,
        "unit": "m",
        "basis": "assumed",
        "source": "A-01"
      },
      "cp": {
        "value": 0.3,
        "unit": "",
        "basis": "literature",
        "source": "A-02: published H-rotor tests 0.25–0.40"
      },
      "tsr": {
        "value": 3,
        "unit": "",
        "basis": "assumed",
        "source": "A-02"
      },
      "rho": {
        "value": 1.225,
        "unit": "kg/m³",
        "basis": "standard",
        "source": "ISA sea level"
      },
      "v_rated": {
        "value": 12,
        "unit": "m/s",
        "basis": "assumed",
        "source": "REQ-PERF-001"
      },
      "v_cut_in": {
        "value": 3.5,
        "unit": "m/s",
        "basis": "assumed",
        "source": "REQ-PERF-002"
      },
      "v_cut_out": {
        "value": 25,
        "unit": "m/s",
        "basis": "assumed"
      },
      "mean_wind": {
        "value": 6,
        "unit": "m/s",
        "basis": "assumed",
        "source": "A-03"
      },
      "weibull_k": {
        "value": 2,
        "unit": "",
        "basis": "assumed",
        "source": "A-03"
      },
      "v_extreme": {
        "value": 52.5,
        "unit": "m/s",
        "basis": "standard",
        "source": "A-04: IEC 61400-2 class III"
      },
      "ct_parked": {
        "value": 1.2,
        "unit": "",
        "basis": "assumed",
        "source": "A-10"
      },
      "rotor_center_height": {
        "value": 10,
        "unit": "m",
        "basis": "assumed",
        "source": "A-08"
      },
      "tower_diameter": {
        "value": 0.4,
        "unit": "m",
        "basis": "assumed",
        "source": "A-08"
      },
      "tower_height": {
        "value": 8,
        "unit": "m",
        "basis": "assumed",
        "source": "A-08"
      },
      "gear_ratio": {
        "value": 6.5,
        "unit": "",
        "basis": "assumed",
        "source": "A-05"
      },
      "eta_gear": {
        "value": 0.96,
        "unit": "",
        "basis": "literature",
        "source": "planetary stage 97–98 %"
      },
      "bearing_loss": {
        "value": 0.04,
        "unit": "kW",
        "basis": "assumed"
      },
      "n_gen": {
        "value": 3,
        "unit": "",
        "basis": "assumed",
        "source": "A-05"
      },
      "p_gen": {
        "value": 1.5,
        "unit": "kW",
        "basis": "assumed",
        "source": "A-05"
      },
      "eta_gen": {
        "value": 0.9,
        "unit": "",
        "basis": "assumed",
        "source": "A-06"
      },
      "gen_fixed_share": {
        "value": 0.35,
        "unit": "",
        "basis": "assumed",
        "source": "A-06"
      },
      "gen_inertia": {
        "value": 0.03,
        "unit": "kg·m²",
        "basis": "assumed"
      },
      "clutch_capacity": {
        "value": 30,
        "unit": "N·m",
        "basis": "assumed"
      },
      "shaft_d": {
        "value": 60,
        "unit": "mm",
        "basis": "assumed",
        "source": "A-09"
      },
      "shaft_sut": {
        "value": 965,
        "unit": "MPa",
        "basis": "literature",
        "source": "aisi-4140-qt typical"
      },
      "shaft_sy": {
        "value": 655,
        "unit": "MPa",
        "basis": "literature",
        "source": "aisi-4140-qt typical"
      },
      "torque_ripple": {
        "value": 0.5,
        "unit": "",
        "basis": "assumed",
        "source": "A-09"
      },
      "shaft_bending": {
        "value": 60,
        "unit": "N·m",
        "basis": "assumed",
        "source": "coupling misalignment allowance"
      },
      "shaft_span_supported": {
        "value": 3.3,
        "unit": "m",
        "basis": "assumed",
        "source": "3 spans with 2 steady bearings"
      },
      "shaft_span_unsupported": {
        "value": 10,
        "unit": "m",
        "basis": "assumed",
        "source": "one span, no steady bearings"
      },
      "overspeed": {
        "value": 1.3,
        "unit": "",
        "basis": "assumed",
        "source": "REQ-SAFE-002"
      },
      "rotating_weight": {
        "value": 4,
        "unit": "kN",
        "basis": "assumed",
        "source": "rotor ≈ 250 kg + shaft ≈ 200 kg"
      },
      "top_bearing_c": {
        "value": 200,
        "unit": "kN",
        "basis": "supplier_data",
        "source": "spherical roller bearing, 60 mm bore class (catalogue order of magnitude)"
      },
      "top_bearing_c0": {
        "value": 216,
        "unit": "kN",
        "basis": "supplier_data",
        "source": "as above"
      },
      "dead_load": {
        "value": 15,
        "unit": "kN",
        "basis": "assumed",
        "source": "rotor, tower, generator house"
      },
      "footing_b": {
        "value": 3.5,
        "unit": "m",
        "basis": "assumed"
      },
      "footing_d": {
        "value": 0.8,
        "unit": "m",
        "basis": "assumed"
      },
      "soil_cover": {
        "value": 0.5,
        "unit": "m",
        "basis": "assumed"
      },
      "q_allow": {
        "value": 150,
        "unit": "kPa",
        "basis": "assumed",
        "source": "A-07"
      },
      "soil_mu": {
        "value": 0.45,
        "unit": "",
        "basis": "assumed",
        "source": "A-07"
      },
      "anchor_n": {
        "value": 12,
        "unit": "",
        "basis": "assumed"
      },
      "bolt_circle": {
        "value": 0.8,
        "unit": "m",
        "basis": "assumed"
      },
      "wind_load_factor": {
        "value": 1,
        "unit": "",
        "basis": "standard",
        "source": "ASCE 7-16/22 strength-level wind (1.0 W) taken with the ultimate wind speed"
      },
      "flange_bcd": {
        "value": 0.6,
        "unit": "m",
        "basis": "assumed"
      },
      "reserve_target": {
        "value": 0.2,
        "unit": "",
        "basis": "assumed",
        "source": "spec §06 default preliminary reserve"
      }
    }
  },
  "calculations": [
    {
      "key": "CALC-01",
      "title": "Rotor power, speed and torque at rated wind",
      "fingerprint": "1e2a31c81edddf",
      "informative": false,
      "method": "wind.rotor_power",
      "version": "1.0.0",
      "inputs": {
        "rotor": "vawt",
        "diameter": 3,
        "height": 4,
        "rho": 1.225,
        "v": 12,
        "cp": 0.3,
        "tsr": 3
      },
      "outputs": [
        {
          "key": "area",
          "label": "Swept area",
          "value": 12,
          "unit": "m²"
        },
        {
          "key": "p_wind",
          "label": "Power in the wind (Cp = 1)",
          "value": 12.701,
          "unit": "kW"
        },
        {
          "key": "p_rotor",
          "label": "Rotor shaft power",
          "value": 3.8102,
          "unit": "kW"
        },
        {
          "key": "rpm",
          "label": "Rotor speed",
          "value": 229.18,
          "unit": "rpm"
        },
        {
          "key": "torque",
          "label": "Rotor shaft torque",
          "value": 158.76,
          "unit": "N·m"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-02",
      "title": "Rotor power at the site mean wind (part load)",
      "fingerprint": "163126148f95dd",
      "informative": false,
      "method": "wind.rotor_power",
      "version": "1.0.0",
      "inputs": {
        "rotor": "vawt",
        "diameter": 3,
        "height": 4,
        "rho": 1.225,
        "v": 6,
        "cp": 0.3,
        "tsr": 3
      },
      "outputs": [
        {
          "key": "area",
          "label": "Swept area",
          "value": 12,
          "unit": "m²"
        },
        {
          "key": "p_wind",
          "label": "Power in the wind (Cp = 1)",
          "value": 1.5876,
          "unit": "kW"
        },
        {
          "key": "p_rotor",
          "label": "Rotor shaft power",
          "value": 0.47628,
          "unit": "kW"
        },
        {
          "key": "rpm",
          "label": "Rotor speed",
          "value": 114.59,
          "unit": "rpm"
        },
        {
          "key": "torque",
          "label": "Rotor shaft torque",
          "value": 39.69,
          "unit": "N·m"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-03",
      "title": "Annual energy production at the site",
      "fingerprint": "1c17bf6170d6b7",
      "informative": false,
      "method": "wind.annual_energy",
      "version": "1.0.0",
      "inputs": {
        "area": 12,
        "rho": 1.225,
        "cp": 0.3,
        "mean_v": 6,
        "k": 2,
        "v_in": 3.5,
        "v_rated": 12,
        "v_out": 25,
        "eta": 0.864,
        "availability": 0.95
      },
      "outputs": [
        {
          "key": "weibull_c",
          "label": "Weibull scale c",
          "value": 6.7703,
          "unit": "m/s"
        },
        {
          "key": "p_rated",
          "label": "Rated rotor power",
          "value": 3.8102,
          "unit": "kW"
        },
        {
          "key": "mean_power",
          "label": "Mean electrical power",
          "value": 0.66612,
          "unit": "kW"
        },
        {
          "key": "aep",
          "label": "Annual energy production",
          "value": 5835.2,
          "unit": "kWh"
        },
        {
          "key": "capacity_factor",
          "label": "Capacity factor (of rated electrical)",
          "value": 20.234,
          "unit": "%"
        },
        {
          "key": "operating_hours",
          "label": "Hours between cut-in and cut-out",
          "value": 6705.6,
          "unit": "h"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-04",
      "title": "Staged generator bank at rated power",
      "fingerprint": "1c7b225deb0d7e",
      "informative": false,
      "method": "drivetrain.staged_generators",
      "version": "1.0.0",
      "inputs": {
        "p_rotor": 3.8102,
        "rotor_rpm": 229.18,
        "ratio": 6.5,
        "eta_gear": 0.96,
        "bearing_loss": 0.04,
        "n_gen": 3,
        "p_gen": 1.5,
        "eta_gen": 0.9,
        "fixed_share": 0.35,
        "engage_at": 0.8
      },
      "outputs": [
        {
          "key": "p_shaft",
          "label": "Power at generator shaft",
          "value": 3.6178,
          "unit": "kW"
        },
        {
          "key": "engaged",
          "label": "Generators engaged",
          "value": 3,
          "unit": ""
        },
        {
          "key": "load_each",
          "label": "Load on each engaged generator",
          "value": 80.395,
          "unit": "%"
        },
        {
          "key": "p_elec",
          "label": "Electrical output (staged)",
          "value": 3.2712,
          "unit": "kW"
        },
        {
          "key": "p_elec_single",
          "label": "Electrical output (one generator of the same total rating)",
          "value": 3.2712,
          "unit": "kW"
        },
        {
          "key": "staging_gain",
          "label": "Gain from staging at this point",
          "value": 0,
          "unit": "kW"
        },
        {
          "key": "loss_gear",
          "label": "Gear loss",
          "value": 0.15241,
          "unit": "kW"
        },
        {
          "key": "loss_bearing",
          "label": "Bearing + seal loss",
          "value": 0.04,
          "unit": "kW"
        },
        {
          "key": "loss_gen",
          "label": "Generator losses",
          "value": 0.34655,
          "unit": "kW"
        },
        {
          "key": "curtailed",
          "label": "Power shed (above installed rating)",
          "value": 0,
          "unit": "kW"
        },
        {
          "key": "efficiency",
          "label": "Rotor-to-electrical efficiency",
          "value": 85.855,
          "unit": "%"
        },
        {
          "key": "gen_rpm",
          "label": "Generator speed",
          "value": 1489.7,
          "unit": "rpm"
        },
        {
          "key": "gen_torque",
          "label": "Torque on each generator shaft",
          "value": 7.7304,
          "unit": "N·m"
        },
        {
          "key": "balance_residual",
          "label": "Energy balance residual",
          "value": 0,
          "unit": "kW"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-05",
      "title": "Staged generator bank at part load: staged vs one generator",
      "fingerprint": "0c625420a0c46d",
      "informative": false,
      "method": "drivetrain.staged_generators",
      "version": "1.0.0",
      "inputs": {
        "p_rotor": 0.47628,
        "rotor_rpm": 114.59,
        "ratio": 6.5,
        "eta_gear": 0.96,
        "bearing_loss": 0.04,
        "n_gen": 3,
        "p_gen": 1.5,
        "eta_gen": 0.9,
        "fixed_share": 0.35,
        "engage_at": 0.8
      },
      "outputs": [
        {
          "key": "p_shaft",
          "label": "Power at generator shaft",
          "value": 0.41723,
          "unit": "kW"
        },
        {
          "key": "engaged",
          "label": "Generators engaged",
          "value": 1,
          "unit": ""
        },
        {
          "key": "load_each",
          "label": "Load on each engaged generator",
          "value": 27.815,
          "unit": "%"
        },
        {
          "key": "p_elec",
          "label": "Electrical output (staged)",
          "value": 0.35719,
          "unit": "kW"
        },
        {
          "key": "p_elec_single",
          "label": "Electrical output (one generator of the same total rating)",
          "value": 0.25721,
          "unit": "kW"
        },
        {
          "key": "staging_gain",
          "label": "Gain from staging at this point",
          "value": 0.099971,
          "unit": "kW"
        },
        {
          "key": "loss_gear",
          "label": "Gear loss",
          "value": 0.019051,
          "unit": "kW"
        },
        {
          "key": "loss_bearing",
          "label": "Bearing + seal loss",
          "value": 0.04,
          "unit": "kW"
        },
        {
          "key": "loss_gen",
          "label": "Generator losses",
          "value": 0.060043,
          "unit": "kW"
        },
        {
          "key": "curtailed",
          "label": "Power shed (above installed rating)",
          "value": 0,
          "unit": "kW"
        },
        {
          "key": "efficiency",
          "label": "Rotor-to-electrical efficiency",
          "value": 74.995,
          "unit": "%"
        },
        {
          "key": "gen_rpm",
          "label": "Generator speed",
          "value": 744.84,
          "unit": "rpm"
        },
        {
          "key": "gen_torque",
          "label": "Torque on each generator shaft",
          "value": 5.3492,
          "unit": "N·m"
        },
        {
          "key": "balance_residual",
          "label": "Energy balance residual",
          "value": 0,
          "unit": "kW"
        }
      ],
      "checks": [],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-06",
      "title": "Energy balance at rated: no output beyond input",
      "fingerprint": "0384e89359244b",
      "informative": false,
      "method": "energy.balance",
      "version": "1.0.0",
      "inputs": {
        "p_in": 3.8102,
        "p_out": 3.2712,
        "losses": 0.53896
      },
      "outputs": [
        {
          "key": "efficiency",
          "label": "Implied efficiency",
          "value": 85.854,
          "unit": "%"
        },
        {
          "key": "unaccounted",
          "label": "Unaccounted losses",
          "value": 0.00004,
          "unit": "kW"
        }
      ],
      "checks": [
        {
          "name": "output within input less known losses",
          "capacity": 3.2712,
          "demand": 3.2712,
          "unit": "kW",
          "ratio": 1,
          "required_ratio": 1,
          "basis": "conservation of energy",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-07",
      "title": "Vertical shaft fatigue at rated torque with 2P ripple",
      "fingerprint": "06eb4d91ece8b7",
      "informative": false,
      "method": "shaft.fatigue",
      "version": "1.0.0",
      "inputs": {
        "d": 60,
        "di": 0,
        "ma": 60,
        "mm": 0,
        "ta": 79.38,
        "tm": 158.76,
        "kf": 1.7,
        "kfs": 1.5,
        "sut": 965,
        "sy": 655,
        "surface": "machined",
        "reliability": "99",
        "kd": 1
      },
      "outputs": [
        {
          "key": "sigma_a",
          "label": "von Mises alternating stress σa'",
          "value": 6.8398,
          "unit": "MPa"
        },
        {
          "key": "sigma_m",
          "label": "von Mises mean stress σm'",
          "value": 9.7254,
          "unit": "MPa"
        },
        {
          "key": "se",
          "label": "Corrected endurance limit Se",
          "value": 227.62,
          "unit": "MPa"
        },
        {
          "key": "ka",
          "label": "Surface factor ka",
          "value": 0.72992,
          "unit": ""
        },
        {
          "key": "kb",
          "label": "Size factor kb",
          "value": 0.79398,
          "unit": ""
        },
        {
          "key": "n_fatigue",
          "label": "Fatigue factor of safety (DE-Goodman)",
          "value": 24.921,
          "unit": ""
        },
        {
          "key": "n_yield",
          "label": "Yield factor of safety (first cycle)",
          "value": 42.641,
          "unit": ""
        }
      ],
      "checks": [
        {
          "name": "fatigue (DE-Goodman)",
          "capacity": 24.921,
          "demand": 1,
          "unit": "factor",
          "ratio": 24.9,
          "required_ratio": 1.2,
          "basis": "project reserve 20 %; machine-design practice is often 1.5–2.0 — reviewer sets the governing value",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "first-cycle yield",
          "capacity": 42.641,
          "demand": 1,
          "unit": "factor",
          "ratio": 42.6,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-08",
      "title": "Shaft critical speed with two steady bearings (3 spans)",
      "fingerprint": "072ed34a50b175",
      "informative": false,
      "method": "shaft.critical_speed",
      "version": "1.0.0",
      "inputs": {
        "length": 3.3,
        "d": 60,
        "di": 0,
        "e": 205,
        "rho": 7850,
        "rpm": 297.934,
        "margin": 1.25
      },
      "outputs": [
        {
          "key": "n_crit",
          "label": "First critical speed",
          "value": 663.4,
          "unit": "rpm"
        },
        {
          "key": "separation",
          "label": "Critical / running speed",
          "value": 2.2267,
          "unit": ""
        },
        {
          "key": "max_span",
          "label": "Longest span keeping the margin",
          "value": 4.4044,
          "unit": "m"
        }
      ],
      "checks": [
        {
          "name": "critical-speed separation",
          "capacity": 663.4,
          "demand": 297.93,
          "unit": "rpm",
          "ratio": 2.23,
          "required_ratio": 1.25,
          "basis": "separation ≥ 1.25 (common practice; confirm with a rotordynamic analysis)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-09",
      "title": "Rejected option: one 10 m span with no steady bearings",
      "fingerprint": "185a19354b59a3",
      "informative": true,
      "method": "shaft.critical_speed",
      "version": "1.0.0",
      "inputs": {
        "length": 10,
        "d": 60,
        "di": 0,
        "e": 205,
        "rho": 7850,
        "rpm": 297.934,
        "margin": 1.25
      },
      "outputs": [
        {
          "key": "n_crit",
          "label": "First critical speed",
          "value": 72.244,
          "unit": "rpm"
        },
        {
          "key": "separation",
          "label": "Critical / running speed",
          "value": 0.24248,
          "unit": ""
        },
        {
          "key": "max_span",
          "label": "Longest span keeping the margin",
          "value": 4.4044,
          "unit": "m"
        }
      ],
      "checks": [
        {
          "name": "critical-speed separation",
          "capacity": 72.244,
          "demand": 297.93,
          "unit": "rpm",
          "ratio": 0.242,
          "required_ratio": 1.25,
          "basis": "separation ≥ 1.25 (common practice; confirm with a rotordynamic analysis)",
          "pass": false,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "fail",
      "errors": []
    },
    {
      "key": "CALC-10",
      "title": "Parked extreme wind on rotor and tower",
      "fingerprint": "0ac614b0714992",
      "informative": false,
      "method": "wind.thrust",
      "version": "1.0.0",
      "inputs": {
        "v": 52.5,
        "rho": 1.225,
        "area": 12,
        "ct": 1.2,
        "h_rotor": 10,
        "tower_d": 0.4,
        "tower_h": 8,
        "cd_tower": 1.2
      },
      "outputs": [
        {
          "key": "q",
          "label": "Velocity pressure",
          "value": 1688.2,
          "unit": "Pa"
        },
        {
          "key": "f_rotor",
          "label": "Rotor force",
          "value": 24.31,
          "unit": "kN"
        },
        {
          "key": "f_tower",
          "label": "Tower force",
          "value": 6.4827,
          "unit": "kN"
        },
        {
          "key": "h_total",
          "label": "Total base shear",
          "value": 30.793,
          "unit": "kN"
        },
        {
          "key": "m_base",
          "label": "Overturning moment at base",
          "value": 269.03,
          "unit": "kN·m"
        }
      ],
      "checks": [],
      "warnings": [
        "Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-11",
      "title": "Top bearing life (weight + operating radial load) and static safety at extreme wind",
      "fingerprint": "08d3b1dec65337",
      "informative": false,
      "method": "bearing.life",
      "version": "1.0.0",
      "inputs": {
        "type": "roller",
        "c": 200,
        "c0": 216,
        "fr": 0.9525600000000001,
        "fa": 4,
        "x_factor": 0.67,
        "y_factor": 3.4,
        "p0": 24.31,
        "rpm": 229.18,
        "reliability": "90",
        "required_h": 100000,
        "s0_required": 2
      },
      "outputs": [
        {
          "key": "p",
          "label": "Equivalent dynamic load P",
          "value": 14.238,
          "unit": "kN"
        },
        {
          "key": "l10",
          "label": "Basic rating life L10",
          "value": 6687.3,
          "unit": "Mrev"
        },
        {
          "key": "l10h",
          "label": "Basic rating life L10h",
          "value": 486320,
          "unit": "h"
        },
        {
          "key": "lnm",
          "label": "Life at 90 % reliability",
          "value": 486320,
          "unit": "h"
        },
        {
          "key": "s0",
          "label": "Static safety factor s0",
          "value": 8.8852,
          "unit": ""
        }
      ],
      "checks": [
        {
          "name": "rating life",
          "capacity": 486320,
          "demand": 100000,
          "unit": "h",
          "ratio": 4.86,
          "required_ratio": 1,
          "basis": "required life (the reserve is in the life requirement)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "static safety",
          "capacity": 8.8852,
          "demand": 2,
          "unit": "",
          "ratio": 4.44,
          "required_ratio": 1,
          "basis": "s0 ≥ 2 (ISO 76 / maker guidance)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "Basic life only: run the maker's calculator (a_ISO, lubrication, contamination) before selection"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-12",
      "title": "Speed-up stage pinion bending (screening)",
      "fingerprint": "0eea5a839c3f3e",
      "informative": false,
      "method": "gear.lewis_bending",
      "version": "1.0.0",
      "inputs": {
        "module": 3,
        "z": 18,
        "face": 30,
        "torque": 36.636923076923075,
        "rpm": 1489.67,
        "allowable": 250
      },
      "outputs": [
        {
          "key": "pitch_d",
          "label": "Pitch diameter",
          "value": 54,
          "unit": "mm"
        },
        {
          "key": "wt",
          "label": "Tangential load Wt",
          "value": 1356.9,
          "unit": "N"
        },
        {
          "key": "v",
          "label": "Pitch-line velocity",
          "value": 4.2119,
          "unit": "m/s"
        },
        {
          "key": "kv",
          "label": "Velocity factor Kv",
          "value": 1.6905,
          "unit": ""
        },
        {
          "key": "y",
          "label": "Lewis form factor Y",
          "value": 0.309,
          "unit": ""
        },
        {
          "key": "sigma",
          "label": "Bending stress",
          "value": 82.483,
          "unit": "MPa"
        }
      ],
      "checks": [
        {
          "name": "tooth bending",
          "capacity": 250,
          "demand": 82.483,
          "unit": "MPa",
          "ratio": 3.03,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "Lewis screening only: rate to AGMA 2001 / ISO 6336 (bending and contact) before selection"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-13",
      "title": "Clutch engagement onto a stationary generator",
      "fingerprint": "12614dbc29779b",
      "informative": false,
      "method": "clutch.engagement",
      "version": "1.0.0",
      "inputs": {
        "j": 0.03,
        "rpm": 1489.67,
        "t": 1.5,
        "t_load": 0,
        "capacity": 30,
        "mass": 1,
        "c": 460,
        "per_hour": 30
      },
      "outputs": [
        {
          "key": "t_req",
          "label": "Torque needed",
          "value": 3.12,
          "unit": "N·m"
        },
        {
          "key": "e_slip",
          "label": "Slip heat per engagement",
          "value": 0.36503,
          "unit": "kJ"
        },
        {
          "key": "dT",
          "label": "Plate temperature rise per engagement",
          "value": 0.79354,
          "unit": "K"
        },
        {
          "key": "heat_rate",
          "label": "Average slip heat in the worst hour",
          "value": 3.0419,
          "unit": "W"
        }
      ],
      "checks": [
        {
          "name": "clutch torque capacity",
          "capacity": 30,
          "demand": 3.12,
          "unit": "N·m",
          "ratio": 9.62,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-14",
      "title": "Tower base flange bolts under parked extreme wind",
      "fingerprint": "070e2299f8f6d6",
      "informative": false,
      "method": "bolt.joint",
      "version": "1.0.0",
      "inputs": {
        "size": "M24",
        "grade": "10.9",
        "n": 16,
        "p_ext": 1793.5333333333333,
        "v_ext": 30.793,
        "preload_frac": 0.7,
        "c_joint": 0.25,
        "k_nut": 0.2,
        "mu": 0.3
      },
      "outputs": [
        {
          "key": "as",
          "label": "Tensile stress area As",
          "value": 352.5,
          "unit": "mm²"
        },
        {
          "key": "fp",
          "label": "Proof load per bolt",
          "value": 292.58,
          "unit": "kN"
        },
        {
          "key": "fi",
          "label": "Preload per bolt",
          "value": 204.8,
          "unit": "kN"
        },
        {
          "key": "torque",
          "label": "Tightening torque",
          "value": 983.06,
          "unit": "N·m"
        },
        {
          "key": "n_load",
          "label": "Load factor n_L",
          "value": 3.1321,
          "unit": ""
        },
        {
          "key": "n_sep",
          "label": "Separation factor n_0",
          "value": 2.4361,
          "unit": ""
        },
        {
          "key": "n_slip",
          "label": "Slip factor",
          "value": 18.82,
          "unit": ""
        }
      ],
      "checks": [
        {
          "name": "bolt load within proof (load factor)",
          "capacity": 87.773,
          "demand": 28.024,
          "unit": "kN",
          "ratio": 3.13,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "joint separation",
          "capacity": 204.8,
          "demand": 84.072,
          "unit": "kN",
          "ratio": 2.44,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "slip (friction grip)",
          "capacity": 579.52,
          "demand": 30.793,
          "unit": "kN",
          "ratio": 18.8,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [],
      "verdict": "pass",
      "errors": []
    },
    {
      "key": "CALC-15",
      "title": "Spread footing: overturning, sliding, soil bearing",
      "fingerprint": "1ab1c2b9aa99ab",
      "informative": false,
      "method": "foundation.spread_footing",
      "version": "1.0.0",
      "inputs": {
        "b": 3.5,
        "depth": 0.8,
        "cover": 0.5,
        "gamma_c": 23.6,
        "gamma_s": 18,
        "v": 15,
        "h": 30.793,
        "m": 269.03,
        "q_allow": 150,
        "mu": 0.45,
        "fs_ot": 1.5,
        "fs_sl": 1.5
      },
      "outputs": [
        {
          "key": "w_footing",
          "label": "Footing weight",
          "value": 231.28,
          "unit": "kN"
        },
        {
          "key": "w_soil",
          "label": "Soil cover weight",
          "value": 110.25,
          "unit": "kN"
        },
        {
          "key": "w_total",
          "label": "Total stabilising vertical load",
          "value": 356.53,
          "unit": "kN"
        },
        {
          "key": "m_ot",
          "label": "Overturning moment at base",
          "value": 309.06,
          "unit": "kN·m"
        },
        {
          "key": "e",
          "label": "Eccentricity",
          "value": 0.86686,
          "unit": "m"
        },
        {
          "key": "q_max",
          "label": "Peak soil pressure",
          "value": 76.896,
          "unit": "kPa"
        },
        {
          "key": "q_min",
          "label": "Minimum soil pressure",
          "value": 0,
          "unit": "kPa"
        },
        {
          "key": "concrete",
          "label": "Concrete volume",
          "value": 9.8,
          "unit": "m³"
        }
      ],
      "checks": [
        {
          "name": "overturning",
          "capacity": 623.93,
          "demand": 309.06,
          "unit": "kN·m",
          "ratio": 2.02,
          "required_ratio": 1.5,
          "basis": "FS ≥ 1.5 (common practice; code combinations govern)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "sliding",
          "capacity": 160.44,
          "demand": 30.793,
          "unit": "kN",
          "ratio": 5.21,
          "required_ratio": 1.5,
          "basis": "FS ≥ 1.5 (common practice; code combinations govern)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "soil bearing",
          "capacity": 150,
          "demand": 76.896,
          "unit": "kPa",
          "ratio": 1.95,
          "required_ratio": 1,
          "basis": "allowable bearing pressure from the geotechnical engineer (already includes its factor)",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "eccentricity 0.87 m exceeds B/6 = 0.58 m: part of the base lifts off the soil (allowed by some codes for wind, not for sustained loads)",
        "Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)"
      ],
      "verdict": "warn",
      "errors": []
    },
    {
      "key": "CALC-16",
      "title": "Anchor rods: steel strength under factored extreme wind",
      "fingerprint": "0ba6b42d89d526",
      "informative": false,
      "method": "anchor.bolt_circle",
      "version": "1.0.0",
      "inputs": {
        "n": 12,
        "dbc": 0.8,
        "size": "M30",
        "grade": "F1554-55",
        "m": 269.03,
        "p": 13.5,
        "h": 30.793
      },
      "outputs": [
        {
          "key": "t_max",
          "label": "Peak anchor tension",
          "value": 110.97,
          "unit": "kN"
        },
        {
          "key": "v_each",
          "label": "Shear per anchor",
          "value": 2.5661,
          "unit": "kN"
        },
        {
          "key": "phi_n",
          "label": "Design tensile strength φNsa",
          "value": 217.37,
          "unit": "kN"
        },
        {
          "key": "phi_v",
          "label": "Design shear strength φVsa",
          "value": 113.03,
          "unit": "kN"
        },
        {
          "key": "interaction",
          "label": "Tension–shear interaction",
          "value": 0.53322,
          "unit": ""
        }
      ],
      "checks": [
        {
          "name": "anchor tension (steel)",
          "capacity": 217.37,
          "demand": 110.97,
          "unit": "kN",
          "ratio": 1.96,
          "required_ratio": 1.2,
          "basis": "LRFD φ factors applied; plus project reserve 20 %",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "anchor shear (steel)",
          "capacity": 113.03,
          "demand": 2.5661,
          "unit": "kN",
          "ratio": 44,
          "required_ratio": 1.2,
          "basis": "project reserve target 20 % (capacity/demand ≥ 1.20)",
          "pass": true,
          "mandatory": true
        },
        {
          "name": "tension–shear interaction (≤ 1.2)",
          "capacity": 1.2,
          "demand": 0.53322,
          "unit": "",
          "ratio": 2.25,
          "required_ratio": 1,
          "basis": "ACI 318 §17.8 interaction",
          "pass": true,
          "mandatory": true
        }
      ],
      "warnings": [
        "Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)"
      ],
      "verdict": "warn",
      "errors": []
    }
  ],
  "traceability": [
    {
      "code": "REQ-PERF-001",
      "text": "Rated electrical output at 12 m/s hub wind speed.",
      "critical": true,
      "verification": "test",
      "nodes": [
        "1",
        "1.1"
      ],
      "runs": [
        {
          "key": "CALC-01",
          "verdict": "pass"
        },
        {
          "key": "CALC-04",
          "verdict": "pass"
        },
        {
          "key": "CALC-06",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-PERF-002",
      "text": "Begin producing power at low wind speed.",
      "critical": false,
      "verification": "test",
      "nodes": [
        "1.1"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-PERF-003",
      "text": "Staged generator engagement shall raise part-load conversion efficiency compared with one generator of the same total rating.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.5"
      ],
      "runs": [
        {
          "key": "CALC-02",
          "verdict": "pass"
        },
        {
          "key": "CALC-05",
          "verdict": "pass"
        },
        {
          "key": "CALC-13",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-PERF-004",
      "text": "Annual energy production shall be reported against conventional geared and direct-drive baselines with the same rotor.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1"
      ],
      "runs": [
        {
          "key": "CALC-03",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the 50-year extreme wind parked without structural failure.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.8"
      ],
      "runs": [
        {
          "key": "CALC-10",
          "verdict": "warn"
        },
        {
          "key": "CALC-14",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid.",
      "critical": true,
      "verification": "test",
      "nodes": [
        "1.6"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-SAFE-003",
      "text": "All rotating parts accessible at ground level shall be guarded.",
      "critical": false,
      "verification": "inspection",
      "nodes": [
        "1.10"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-INT-001",
      "text": "The vertical shaft shall run clear of its bending critical speeds.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.3"
      ],
      "runs": [
        {
          "key": "CALC-08",
          "verdict": "pass"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-STR-001",
      "text": "The foundation shall resist overturning and sliding and stay within allowable soil bearing.",
      "critical": true,
      "verification": "analysis",
      "nodes": [
        "1.9"
      ],
      "runs": [
        {
          "key": "CALC-15",
          "verdict": "warn"
        },
        {
          "key": "CALC-16",
          "verdict": "warn"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-LIFE-001",
      "text": "Design life.",
      "critical": false,
      "verification": "analysis",
      "nodes": [
        "1"
      ],
      "runs": [
        {
          "key": "CALC-07",
          "verdict": "pass"
        },
        {
          "key": "CALC-12",
          "verdict": "warn"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-LIFE-002",
      "text": "Rolling bearings shall reach their rating life without replacement.",
      "critical": false,
      "verification": "analysis",
      "nodes": [
        "1.2"
      ],
      "runs": [
        {
          "key": "CALC-11",
          "verdict": "warn"
        }
      ],
      "status": "assumed"
    },
    {
      "code": "REQ-MAINT-001",
      "text": "Generators, clutches, brake and gearbox shall be replaceable from ground level without climbing or a crane.",
      "critical": false,
      "verification": "demonstration",
      "nodes": [
        "1.10"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-ENV-001",
      "text": "Operating environment.",
      "critical": false,
      "verification": "analysis",
      "nodes": [
        "1.10"
      ],
      "runs": [],
      "status": "none"
    },
    {
      "code": "REQ-ENV-002",
      "text": "Noise at the nearest dwelling.",
      "critical": false,
      "verification": "test",
      "nodes": [],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-REG-001",
      "text": "Follow a recognised small-wind certification path.",
      "critical": false,
      "verification": "inspection",
      "nodes": [
        "1"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-REG-002",
      "text": "Grid-connected operation shall use listed interconnection equipment.",
      "critical": false,
      "verification": "inspection",
      "nodes": [
        "1.7"
      ],
      "runs": [],
      "status": "test_planned"
    },
    {
      "code": "REQ-COST-001",
      "text": "Prototype build cost and levelised cost of energy shall be estimated against the baselines.",
      "critical": false,
      "verification": "analysis",
      "nodes": [],
      "runs": [],
      "status": "none"
    }
  ],
  "findings": [
    {
      "code": "F-001",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-01: Import the patent / design documents for the vertical transmission and the staged clutch arrangement.",
      "refs": [
        "G-01",
        "1",
        "1.4.2",
        "1.5.1"
      ]
    },
    {
      "code": "F-002",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-02: Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?",
      "refs": [
        "G-02",
        "1.1",
        "1.2"
      ]
    },
    {
      "code": "F-005",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?",
      "refs": [
        "G-05",
        "1.5.1",
        "1.5.4"
      ]
    },
    {
      "code": "F-008",
      "severity": "blocking",
      "class": "blocking",
      "message": "G-08: Prototype budget and the funding target.",
      "refs": [
        "G-08",
        "1"
      ]
    },
    {
      "code": "F-003",
      "severity": "warning",
      "class": "assumable",
      "message": "G-03: Where will the prototype stand? Site wind data (or a nearby met station) and the permitting authority.",
      "refs": [
        "G-03",
        "1.1",
        "1.8",
        "1.9"
      ]
    },
    {
      "code": "F-004",
      "severity": "warning",
      "class": "assumable",
      "message": "G-04: Geotechnical report: allowable bearing, friction, frost depth, water table.",
      "refs": [
        "G-04",
        "1.9"
      ]
    },
    {
      "code": "F-006",
      "severity": "warning",
      "class": "assumable",
      "message": "G-06: Which generators: maker, rated speed, efficiency map, inertia?",
      "refs": [
        "G-06",
        "1.5.2"
      ]
    },
    {
      "code": "F-010",
      "severity": "warning",
      "class": "completeness",
      "message": "1.1.3 Rotor hub has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.1.3"
      ]
    },
    {
      "code": "F-011",
      "severity": "warning",
      "class": "completeness",
      "message": "1.2.3 Bearing housing, seals and lubrication has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.2.3"
      ]
    },
    {
      "code": "F-012",
      "severity": "warning",
      "class": "completeness",
      "message": "1.4.2 Power take-off to generator branches has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.4.2"
      ]
    },
    {
      "code": "F-014",
      "severity": "warning",
      "class": "completeness",
      "message": "1.5.4 Clutch magnet drivers and engagement controller has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.5.4"
      ]
    },
    {
      "code": "F-015",
      "severity": "warning",
      "class": "completeness",
      "message": "1.7.1 Supervisory controller has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.7.1"
      ]
    },
    {
      "code": "F-016",
      "severity": "warning",
      "class": "completeness",
      "message": "1.8.1 Tubular steel tower, flanged sections has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.8.1"
      ]
    },
    {
      "code": "F-017",
      "severity": "warning",
      "class": "completeness",
      "message": "1.8.4 Service access: hatch, climbing / tower-lowering provision has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.8.4"
      ]
    },
    {
      "code": "F-019",
      "severity": "warning",
      "class": "completeness",
      "message": "1.10.1 Weatherproof generator house has no parts yet: decompose it to a testable work package or mark it bought.",
      "refs": [
        "1.10.1"
      ]
    },
    {
      "code": "F-031",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-01 not yet approved: Rotor is a 3-blade H-type vertical-axis rotor, 3 m diameter × 4 m high, on top of the tower.",
      "refs": [
        "A-01",
        "1.1",
        "1.2",
        "1.8",
        "1.9"
      ]
    },
    {
      "code": "F-032",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-02 not yet approved: Rotor power coefficient Cp = 0.30 at tip-speed ratio 3 (mid-range of published H-rotor tests).",
      "refs": [
        "A-02",
        "1.1",
        "1.5"
      ]
    },
    {
      "code": "F-033",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-03 not yet approved: Site wind: annual mean 6 m/s at rotor height, Rayleigh distribution (no site data yet).",
      "refs": [
        "A-03",
        "1.1"
      ]
    },
    {
      "code": "F-034",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-05 not yet approved: Three 1.5 kW permanent-magnet generators behind a 6.5:1 speed-up stage.",
      "refs": [
        "A-05",
        "1.4",
        "1.5"
      ]
    },
    {
      "code": "F-035",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-07 not yet approved: Allowable soil bearing 150 kPa, friction 0.45 (no geotechnical report).",
      "refs": [
        "A-07",
        "1.9"
      ]
    },
    {
      "code": "F-036",
      "severity": "warning",
      "class": "assumable",
      "message": "High-sensitivity assumption A-11 not yet approved: Clutch: a centrifugal shoe clutch whose engagement is held off or released by an electromagnet, so a controller can set the engagement threshold by power.",
      "refs": [
        "A-11",
        "1.5.1",
        "1.5.4"
      ]
    },
    {
      "code": "F-037",
      "severity": "warning",
      "class": "traceability",
      "message": "REQ-ENV-002 is not allocated to any part of the structure (orphan requirement).",
      "refs": [
        "REQ-ENV-002"
      ]
    },
    {
      "code": "F-038",
      "severity": "warning",
      "class": "traceability",
      "message": "REQ-COST-001 is not allocated to any part of the structure (orphan requirement).",
      "refs": [
        "REQ-COST-001"
      ]
    },
    {
      "code": "F-007",
      "severity": "info",
      "class": "deferred",
      "message": "G-07: Grid-tied, battery-based or both?",
      "refs": [
        "G-07",
        "1.7.2"
      ]
    },
    {
      "code": "F-009",
      "severity": "info",
      "class": "deferred",
      "message": "G-09: Local noise and setback limits.",
      "refs": [
        "G-09",
        "1.1"
      ]
    },
    {
      "code": "F-013",
      "severity": "info",
      "class": "evidence",
      "message": "1.4.3 Gearbox lubricant has no sizing method, standard or catalogue component behind it.",
      "refs": [
        "1.4.3"
      ]
    },
    {
      "code": "F-018",
      "severity": "info",
      "class": "evidence",
      "message": "1.9.4 Base-plate grout has no sizing method, standard or catalogue component behind it.",
      "refs": [
        "1.9.4"
      ]
    },
    {
      "code": "F-020",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-01 (rotational) not yet defined: Rotor hub to top shaft segment: torque, weight and rotor bending moment.",
      "refs": [
        "I-01",
        "1.1.3",
        "1.3.1"
      ]
    },
    {
      "code": "F-021",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-02 (structural) not yet defined: Top bearing housing to tower top: radial rotor loads and weight into the tower.",
      "refs": [
        "I-02",
        "1.2",
        "1.8.1"
      ]
    },
    {
      "code": "F-022",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-04 (structural) not yet defined: Steady bearings to tower brackets: radial support only.",
      "refs": [
        "I-04",
        "1.3.3",
        "1.3.4"
      ]
    },
    {
      "code": "F-023",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-05 (rotational) not yet defined: Shaft bottom to gearbox input (coupling, axial float allowance for thermal growth of the long shaft).",
      "refs": [
        "I-05",
        "1.3.1",
        "1.4.1"
      ]
    },
    {
      "code": "F-024",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-06 (rotational) not yet defined: Power take-off to each clutch.",
      "refs": [
        "I-06",
        "1.4.2",
        "1.5.1"
      ]
    },
    {
      "code": "F-025",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-08 (signal) not yet defined: Magnet driver command to each clutch; engagement state feedback.",
      "refs": [
        "I-08",
        "1.5.4",
        "1.5.1"
      ]
    },
    {
      "code": "F-026",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-09 (electrical) not yet defined: Generator AC to rectifiers / DC bus.",
      "refs": [
        "I-09",
        "1.5.2",
        "1.7.2"
      ]
    },
    {
      "code": "F-027",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-10 (signal) not yet defined: Brake release / apply and overspeed trip.",
      "refs": [
        "I-10",
        "1.6.1",
        "1.7.1"
      ]
    },
    {
      "code": "F-028",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-11 (structural) not yet defined: Base plate to anchor rods: tension, compression and shear.",
      "refs": [
        "I-11",
        "1.8.3",
        "1.9.3"
      ]
    },
    {
      "code": "F-029",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-12 (structural) not yet defined: Footing to soil: bearing pressure, sliding resistance.",
      "refs": [
        "I-12",
        "1.9.1",
        "1.9"
      ]
    },
    {
      "code": "F-030",
      "severity": "info",
      "class": "completeness",
      "message": "Interface I-13 (thermal) not yet defined: Generator and gearbox heat rejected from the house.",
      "refs": [
        "I-13",
        "1.10.1",
        "1.5.2"
      ]
    },
    {
      "code": "F-039",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-01 rests on assumed values: rotor_diameter, rotor_height, v_rated, tsr.",
      "refs": [
        "CALC-01"
      ]
    },
    {
      "code": "F-040",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-02 rests on assumed values: rotor_diameter, rotor_height, mean_wind, tsr.",
      "refs": [
        "CALC-02"
      ]
    },
    {
      "code": "F-041",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-03 rests on assumed values: mean_wind, weibull_k, v_cut_in, v_rated, v_cut_out, eta_gen.",
      "refs": [
        "CALC-03"
      ]
    },
    {
      "code": "F-042",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-04 rests on assumed values: gear_ratio, bearing_loss, n_gen, p_gen, eta_gen, gen_fixed_share.",
      "refs": [
        "CALC-04"
      ]
    },
    {
      "code": "F-043",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-05 rests on assumed values: gear_ratio, bearing_loss, n_gen, p_gen, eta_gen, gen_fixed_share.",
      "refs": [
        "CALC-05"
      ]
    },
    {
      "code": "F-044",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-07: fatigue (DE-Goodman) has 24.9× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-07",
        "1.3.1"
      ]
    },
    {
      "code": "F-045",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-07: first-cycle yield has 42.6× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-07",
        "1.3.1"
      ]
    },
    {
      "code": "F-046",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-07 rests on assumed values: shaft_d, shaft_bending, torque_ripple.",
      "refs": [
        "CALC-07"
      ]
    },
    {
      "code": "F-047",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-08 rests on assumed values: shaft_span_supported, shaft_d, overspeed.",
      "refs": [
        "CALC-08"
      ]
    },
    {
      "code": "F-048",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-10 rests on assumed values: ct_parked, rotor_center_height, tower_diameter, tower_height.",
      "refs": [
        "CALC-10"
      ]
    },
    {
      "code": "F-049",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-11: rating life has 4.86× capacity against 1 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-11",
        "1.2.1"
      ]
    },
    {
      "code": "F-050",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-11: static safety has 4.44× capacity against 1 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-11",
        "1.2.1"
      ]
    },
    {
      "code": "F-051",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-11 rests on assumed values: v_rated, rotating_weight.",
      "refs": [
        "CALC-11"
      ]
    },
    {
      "code": "F-052",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-12 rests on assumed values: gear_ratio.",
      "refs": [
        "CALC-12"
      ]
    },
    {
      "code": "F-053",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-13: clutch torque capacity has 9.62× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-13",
        "1.5.1"
      ]
    },
    {
      "code": "F-054",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-13 rests on assumed values: gen_inertia, gear_ratio, clutch_capacity.",
      "refs": [
        "CALC-13"
      ]
    },
    {
      "code": "F-055",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-14: slip (friction grip) has 18.8× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-14",
        "1.8.2"
      ]
    },
    {
      "code": "F-056",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-14 rests on assumed values: flange_bcd.",
      "refs": [
        "CALC-14"
      ]
    },
    {
      "code": "F-057",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-15 rests on assumed values: footing_b, footing_d, soil_cover, dead_load, q_allow, soil_mu.",
      "refs": [
        "CALC-15"
      ]
    },
    {
      "code": "F-058",
      "severity": "info",
      "class": "completeness",
      "message": "CALC-16: anchor shear (steel) has 44× capacity against 1.2 required — possible overdesign; consider a lighter or cheaper option (other checks may govern).",
      "refs": [
        "CALC-16",
        "1.9.3"
      ]
    },
    {
      "code": "F-059",
      "severity": "info",
      "class": "evidence",
      "message": "CALC-16 rests on assumed values: anchor_n, bolt_circle, dead_load.",
      "refs": [
        "CALC-16"
      ]
    },
    {
      "code": "F-060",
      "severity": "info",
      "class": "evidence",
      "message": "30 referenced standard(s) not yet acquired or edition-checked: IEC 61400-2, IEC 61400-12-1, ANSI/AISC 360, AWS D1.1, ISO 898-1, VDI 2230 Part 1, ISO 281, ISO 76, ISO 286-1/-2, DIN 743, ISO 21940-11, ANSI/AGMA 2001-D04, ISO 6336-1/-2/-3, ANSI/AGMA/AWEA 6006, IEC 60034-1/-2-1, IEC 60204-1, IEC 61000 series, ISO 13849-1/-2, ISO 12100, UL 1741, IEEE 1547, NFPA 70 (NEC) Art. 690, 694, 705, IEC 60529, ISO 20816-1/-21, ASCE/SEI 7, 29 CFR 1910 / 1926, ACI 318, International Building Code (as adopted locally), ASTM A615 / A706, ASTM F1554.",
      "refs": [
        "iec-61400-2",
        "iec-61400-12-1",
        "aisc-360",
        "aws-d1-1",
        "iso-898-1",
        "vdi-2230",
        "iso-281",
        "iso-76",
        "iso-286",
        "din-743",
        "iso-21940",
        "agma-2001",
        "iso-6336",
        "agma-6006",
        "iec-60034",
        "iec-60204-1",
        "iec-61000",
        "iso-13849",
        "iso-12100",
        "ul-1741",
        "ieee-1547",
        "nfpa-70",
        "iec-60529",
        "iso-20816",
        "asce-7",
        "osha-1910",
        "aci-318",
        "ibc",
        "astm-a615",
        "astm-f1554"
      ]
    },
    {
      "code": "F-061",
      "severity": "info",
      "class": "completeness",
      "message": "2 electronics item(s) to hand off to VX Design: Clutch magnet drivers and engagement controller; Supervisory controller.",
      "refs": [
        "1.5.4",
        "1.7.1"
      ]
    }
  ],
  "plan": [
    {
      "inputs": [
        "Inventor interview",
        "Patent / design documents"
      ],
      "depends_on": [],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S1-BRIEF",
      "stage": "S1",
      "title": "Concept brief and open-question register",
      "discipline": "systems",
      "deliverable": "Concept brief v1 with open-question register",
      "method": "Interview the inventor; import patents, sketches, CAD and prior studies",
      "role": "Systems engineer",
      "hours": 6,
      "acceptance": "Brief states function, environment, scale, budget and constraints; every unknown is in the register"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1",
        "1.4.2",
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-01",
      "stage": "S1",
      "title": "Resolve G-01: Import the patent / design documents for the vertical transmission and the staged clutch arrangement.",
      "discipline": "systems",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Systems engineer",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1.1",
        "1.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-02",
      "stage": "S1",
      "title": "Resolve G-02: Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?",
      "discipline": "aero_fluids",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Aerodynamicist",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1.5.1",
        "1.5.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-05",
      "stage": "S1",
      "title": "Resolve G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?",
      "discipline": "mechanical",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Mechanical engineer",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF"
      ],
      "nodes": [
        "1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "high",
      "key": "S1-G-08",
      "stage": "S1",
      "title": "Resolve G-08: Prototype budget and the funding target.",
      "discipline": "cost",
      "deliverable": "Answer recorded with its source, or an approved assumption",
      "method": "Targeted question to the inventor or a research task",
      "role": "Project controls",
      "hours": 4,
      "acceptance": "Gap closed or reclassified with reason"
    },
    {
      "inputs": [],
      "depends_on": [
        "S1-BRIEF",
        "S1-G-01",
        "S1-G-02",
        "S1-G-05",
        "S1-G-08"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002",
        "REQ-PERF-003",
        "REQ-PERF-004",
        "REQ-SAFE-001",
        "REQ-SAFE-002",
        "REQ-SAFE-003",
        "REQ-INT-001",
        "REQ-STR-001",
        "REQ-LIFE-001",
        "REQ-LIFE-002",
        "REQ-MAINT-001",
        "REQ-ENV-001",
        "REQ-ENV-002",
        "REQ-REG-001",
        "REQ-REG-002",
        "REQ-COST-001"
      ],
      "approval_gate": true,
      "risk": "medium",
      "key": "S2-REQ",
      "stage": "S2",
      "title": "Requirements baseline",
      "discipline": "systems",
      "deliverable": "Requirements baseline (17 requirements) with measurable targets",
      "method": "Derive measurable targets, jurisdiction, design life and safety requirements from the brief",
      "role": "Systems engineer",
      "hours": 8,
      "acceptance": "Every requirement measurable and verifiable; inventor approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S2-REQ"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "medium",
      "key": "S2-CONCEPTS",
      "stage": "S2",
      "title": "Alternative concepts and baselines",
      "discipline": "systems",
      "deliverable": "Concept comparison incl. conventional baselines; schematic diagrams",
      "method": "Generate alternatives; score transparently; include the conventional and direct-drive (or fixed) baselines",
      "role": "Systems engineer",
      "hours": 12,
      "acceptance": "Selected concept recorded with reasons"
    },
    {
      "inputs": [],
      "depends_on": [
        "S2-CONCEPTS"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S3-DECOMP",
      "stage": "S3",
      "title": "System decomposition review",
      "discipline": "systems",
      "deliverable": "Product structure (48 items) with functions and interfaces",
      "method": "Recursive decomposition to testable work packages; check functions ↔ subsystems; review gap findings",
      "role": "Systems engineer",
      "hours": 8,
      "acceptance": "No orphan function or requirement; every part has discipline, analyses, standards and acceptance test"
    },
    {
      "inputs": [
        "IEC 61400-2",
        "IEC 61400-12-1",
        "ANSI/AISC 360",
        "AWS D1.1",
        "ISO 898-1",
        "VDI 2230 Part 1",
        "ISO 281",
        "ISO 76",
        "ISO 286-1/-2",
        "DIN 743",
        "ISO 21940-11",
        "ANSI/AGMA 2001-D04",
        "ISO 6336-1/-2/-3",
        "ANSI/AGMA/AWEA 6006",
        "IEC 60034-1/-2-1",
        "IEC 60204-1",
        "IEC 61000 series",
        "ISO 13849-1/-2",
        "ISO 12100",
        "UL 1741",
        "IEEE 1547",
        "NFPA 70 (NEC) Art. 690, 694, 705",
        "IEC 60529",
        "ISO 20816-1/-21",
        "ASCE/SEI 7",
        "29 CFR 1910 / 1926",
        "ACI 318",
        "International Building Code (as adopted locally)",
        "ASTM A615 / A706",
        "ASTM F1554"
      ],
      "depends_on": [
        "S3-DECOMP"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S3-STANDARDS",
      "stage": "S3",
      "title": "Standards applicability matrix",
      "discipline": "compliance",
      "deliverable": "Applicability matrix for 30 standards; acquisition tasks for missing documents",
      "method": "Resolve jurisdiction, edition and amendments; map clauses to requirements (registry workflow)",
      "role": "Compliance engineer",
      "hours": 30,
      "acceptance": "Each standard: edition identified, acquired or purchase task raised, clauses mapped"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-DECOMP",
        "S3-STANDARDS"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S3-PLAN",
      "stage": "S3",
      "title": "Approve the development plan",
      "discipline": "systems",
      "deliverable": "Approved development plan and staffing",
      "method": "Review this task graph, estimates and gates",
      "role": "Project lead",
      "hours": 3,
      "acceptance": "Inventor / owner approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.1",
      "stage": "S4",
      "title": "Preliminary design: Rotor",
      "discipline": "aero_fluids",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Aerodynamicist",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.2"
      ],
      "requirements": [
        "REQ-LIFE-002"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-DES-1.2",
      "stage": "S4",
      "title": "Preliminary design: Top bearing and rotor support",
      "discipline": "mechanical",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Mechanical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.3"
      ],
      "requirements": [
        "REQ-INT-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.3",
      "stage": "S4",
      "title": "Preliminary design: Vertical transmission shaft",
      "discipline": "mechanical",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Mechanical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-DES-1.4",
      "stage": "S4",
      "title": "Preliminary design: Ground-level gear stage",
      "discipline": "mechanical",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Mechanical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.5"
      ],
      "requirements": [
        "REQ-PERF-003"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.5",
      "stage": "S4",
      "title": "Preliminary design: Staged generator bank",
      "discipline": "electrical_power",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Electrical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.6"
      ],
      "requirements": [
        "REQ-SAFE-002"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.6",
      "stage": "S4",
      "title": "Preliminary design: Braking and overspeed protection",
      "discipline": "controls",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Controls engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.7"
      ],
      "requirements": [
        "REQ-REG-002"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-DES-1.7",
      "stage": "S4",
      "title": "Preliminary design: Power electronics, controls and electrical",
      "discipline": "electrical_power",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Electrical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.8"
      ],
      "requirements": [
        "REQ-SAFE-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.8",
      "stage": "S4",
      "title": "Preliminary design: Tower",
      "discipline": "structural",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Structural engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.9"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "medium",
      "key": "S4-DES-1.9",
      "stage": "S4",
      "title": "Preliminary design: Foundation",
      "discipline": "civil_geotech",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Civil / geotechnical engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [
        "1.10"
      ],
      "requirements": [
        "REQ-SAFE-003",
        "REQ-MAINT-001",
        "REQ-ENV-001"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-DES-1.10",
      "stage": "S4",
      "title": "Preliminary design: Generator house, guards and service provisions",
      "discipline": "manufacturing",
      "deliverable": "Layout, load path, parametric CAD and assumptions list",
      "method": "Size from the design basis; select materials and components from the libraries",
      "role": "Manufacturing engineer",
      "hours": 16,
      "acceptance": "Load path closed; every part sized or sourced"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.1.1",
      "stage": "S4",
      "title": "Detail: Blades (H-rotor, pultruded aerofoil)",
      "discipline": "aero_fluids",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (gfrp-pultruded); confirm against governing specification",
      "role": "Aerodynamicist",
      "hours": 10,
      "acceptance": "Blade static test to 1.35 × extreme load; mass and balance within tolerance"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.1.2",
      "stage": "S4",
      "title": "Detail: Blade struts / arms",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (al-6061-t6); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Fatigue check at 2P cyclic load; joint test"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.1.4",
      "stage": "S4",
      "title": "Source: Blade and strut fasteners",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2"
      ],
      "nodes": [
        "1.2.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.2.1",
      "stage": "S4",
      "title": "Source: Top radial bearing (spherical roller)",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2"
      ],
      "nodes": [
        "1.2.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.2.2",
      "stage": "S4",
      "title": "Source: Thrust bearing carrying rotor and shaft weight",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.3.1",
      "stage": "S4",
      "title": "Detail: Shaft segments",
      "discipline": "mechanical",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (aisi-4140-qt); confirm against governing specification",
      "role": "Mechanical engineer",
      "hours": 10,
      "acceptance": "Fatigue reserve ≥ target; straightness ≤ 0.1 mm/m; balance G6.3"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.3.2",
      "stage": "S4",
      "title": "Source: Segment couplings (disc type)",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.3.3",
      "stage": "S4",
      "title": "Source: Intermediate steady bearings",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3"
      ],
      "nodes": [
        "1.3.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.3.4",
      "stage": "S4",
      "title": "Detail: Steady-bearing brackets in tower",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a36); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Bracket stiffness ≥ 10 × bearing radial stiffness requirement"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4"
      ],
      "nodes": [
        "1.4.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.4.1",
      "stage": "S4",
      "title": "Source: Speed-up gearbox (planetary or helical)",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4"
      ],
      "nodes": [
        "1.4.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.4.3",
      "stage": "S4",
      "title": "Source: Gearbox lubricant",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5"
      ],
      "nodes": [
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.5.1",
      "stage": "S4",
      "title": "Detail: Magnetically controlled centrifugal clutches",
      "discipline": "mechanical",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (ndfeb-n42); confirm against governing specification",
      "role": "Mechanical engineer",
      "hours": 10,
      "acceptance": "Engages and releases at set thresholds with hysteresis; slip heat within plate rating at 30 engagements/h"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5"
      ],
      "nodes": [
        "1.5.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.5.2",
      "stage": "S4",
      "title": "Source: Permanent-magnet generators 1.5 kW",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5"
      ],
      "nodes": [
        "1.5.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.5.3",
      "stage": "S4",
      "title": "Source: Generator couplings (jaw)",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.6"
      ],
      "nodes": [
        "1.6.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.6.1",
      "stage": "S4",
      "title": "Source: Spring-applied fail-safe brake",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.6"
      ],
      "nodes": [
        "1.6.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.6.2",
      "stage": "S4",
      "title": "Source: Redundant overspeed sensing",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.7"
      ],
      "nodes": [
        "1.7.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.7.2",
      "stage": "S4",
      "title": "Source: Rectifiers, DC bus and listed hybrid inverter",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.7"
      ],
      "nodes": [
        "1.7.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.7.3",
      "stage": "S4",
      "title": "Source: Dump load / diversion resistor",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.7"
      ],
      "nodes": [
        "1.7.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.7.4",
      "stage": "S4",
      "title": "Source: Sensors: anemometer, shaft speed/torque, vibration, temperatures",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.7"
      ],
      "nodes": [
        "1.7.5"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.7.5",
      "stage": "S4",
      "title": "Source: Enclosures, disconnects, wiring and earthing",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.8"
      ],
      "nodes": [
        "1.8.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.8.2",
      "stage": "S4",
      "title": "Source: Tower base flange bolts (M24, class 10.9)",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.8"
      ],
      "nodes": [
        "1.8.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.8.3",
      "stage": "S4",
      "title": "Detail: Tower base plate",
      "discipline": "structural",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a36); confirm against governing specification",
      "role": "Structural engineer",
      "hours": 10,
      "acceptance": "Plate bending and weld checks (AISC DG1)"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9"
      ],
      "nodes": [
        "1.9.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.9.1",
      "stage": "S4",
      "title": "Detail: Reinforced-concrete spread footing",
      "discipline": "civil_geotech",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (concrete-28); confirm against governing specification",
      "role": "Civil / geotechnical engineer",
      "hours": 10,
      "acceptance": "FS ≥ 1.5 overturning/sliding; bearing ≤ allowable from the geotechnical report"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9"
      ],
      "nodes": [
        "1.9.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.9.2",
      "stage": "S4",
      "title": "Source: Reinforcement",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9"
      ],
      "nodes": [
        "1.9.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.9.3",
      "stage": "S4",
      "title": "Source: Anchor rods (M30, F1554 Gr 55) and setting template",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9"
      ],
      "nodes": [
        "1.9.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.9.4",
      "stage": "S4",
      "title": "Source: Base-plate grout",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9"
      ],
      "nodes": [
        "1.9.5"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-SRC-1.9.5",
      "stage": "S4",
      "title": "Source: Earthing electrode and lightning protection",
      "discipline": "sourcing",
      "deliverable": "Candidate part numbers (≥ 2 makers), datasheets, price and lead time",
      "method": "Search maker catalogues; record quote date and basis",
      "role": "Buyer",
      "hours": 3,
      "acceptance": "Ratings meet the sizing result with reserve; quote dated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.10"
      ],
      "nodes": [
        "1.10.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.10.2",
      "stage": "S4",
      "title": "Detail: Guards on rotating parts",
      "discipline": "manufacturing",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a36); confirm against governing specification",
      "role": "Manufacturing engineer",
      "hours": 10,
      "acceptance": "Interlocked access; ISO 13857 distances"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.10"
      ],
      "nodes": [
        "1.10.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-PART-1.10.3",
      "stage": "S4",
      "title": "Detail: Lifting points and generator slide rails",
      "discipline": "manufacturing",
      "deliverable": "Part record: geometry envelope, material grade and condition, tolerances, process",
      "method": "Material from library (astm-a36); confirm against governing specification",
      "role": "Manufacturing engineer",
      "hours": 10,
      "acceptance": "Generator swap demonstrated in ≤ 4 h"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-PART-1.1.1",
        "S4-PART-1.1.2",
        "S4-SRC-1.1.4",
        "S4-SRC-1.2.1",
        "S4-SRC-1.2.2",
        "S4-PART-1.3.1",
        "S4-SRC-1.3.2",
        "S4-SRC-1.3.3",
        "S4-PART-1.3.4",
        "S4-SRC-1.4.1",
        "S4-SRC-1.4.3",
        "S4-PART-1.5.1",
        "S4-SRC-1.5.2",
        "S4-SRC-1.5.3",
        "S4-SRC-1.6.1",
        "S4-SRC-1.6.2",
        "S4-SRC-1.7.2",
        "S4-SRC-1.7.3",
        "S4-SRC-1.7.4",
        "S4-SRC-1.7.5",
        "S4-SRC-1.8.2",
        "S4-PART-1.8.3",
        "S4-PART-1.9.1",
        "S4-SRC-1.9.2",
        "S4-SRC-1.9.3",
        "S4-SRC-1.9.4",
        "S4-SRC-1.9.5",
        "S4-PART-1.10.2",
        "S4-PART-1.10.3"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S4-BOM",
      "stage": "S4",
      "title": "Preliminary BOM",
      "discipline": "sourcing",
      "deliverable": "Part-level BOM with make/buy, quantities, cost ranges and lead times",
      "method": "Roll up the product structure",
      "role": "Buyer",
      "hours": 4,
      "acceptance": "Every part has quantity, make/buy and a cost range with its basis"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-01",
      "stage": "S5",
      "title": "Rotor power, speed and torque at rated wind",
      "discipline": "aero_fluids",
      "deliverable": "Wind rotor power, speed and torque — result with checks and validity",
      "method": "Deterministic method wind.rotor_power v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Aerodynamicist",
      "hours": 3,
      "calc": "CALC-01",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-003"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-02",
      "stage": "S5",
      "title": "Rotor power at the site mean wind (part load)",
      "discipline": "aero_fluids",
      "deliverable": "Wind rotor power, speed and torque — result with checks and validity",
      "method": "Deterministic method wind.rotor_power v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Aerodynamicist",
      "hours": 3,
      "calc": "CALC-02",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.1",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.1"
      ],
      "requirements": [
        "REQ-PERF-004"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-03",
      "stage": "S5",
      "title": "Annual energy production at the site",
      "discipline": "aero_fluids",
      "deliverable": "Annual energy production (Weibull site) — result with checks and validity",
      "method": "Deterministic method wind.annual_energy v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Aerodynamicist",
      "hours": 3,
      "calc": "CALC-03",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.5"
      ],
      "requirements": [
        "REQ-PERF-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-04",
      "stage": "S5",
      "title": "Staged generator bank at rated power",
      "discipline": "mechanical",
      "deliverable": "Staged multi-generator drivetrain: energy balance — result with checks and validity",
      "method": "Deterministic method drivetrain.staged_generators v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-04",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5",
        "S5-CALC-02"
      ],
      "nodes": [
        "1.5"
      ],
      "requirements": [
        "REQ-PERF-003"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-05",
      "stage": "S5",
      "title": "Staged generator bank at part load: staged vs one generator",
      "discipline": "mechanical",
      "deliverable": "Staged multi-generator drivetrain: energy balance — result with checks and validity",
      "method": "Deterministic method drivetrain.staged_generators v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-05",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5",
        "S5-CALC-01",
        "S5-CALC-04"
      ],
      "nodes": [
        "1.5"
      ],
      "requirements": [
        "REQ-PERF-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-06",
      "stage": "S5",
      "title": "Energy balance at rated: no output beyond input",
      "discipline": "systems",
      "deliverable": "Energy balance check — result with checks and validity",
      "method": "Deterministic method energy.balance v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Systems engineer",
      "hours": 3,
      "calc": "CALC-06",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.3.1"
      ],
      "requirements": [
        "REQ-LIFE-001"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S5-CALC-07",
      "stage": "S5",
      "title": "Vertical shaft fatigue at rated torque with 2P ripple",
      "discipline": "mechanical",
      "deliverable": "Shaft fatigue and yield (DE-Goodman) — result with checks and validity",
      "method": "Deterministic method shaft.fatigue v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-07",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.3.3"
      ],
      "requirements": [
        "REQ-INT-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-08",
      "stage": "S5",
      "title": "Shaft critical speed with two steady bearings (3 spans)",
      "discipline": "mechanical",
      "deliverable": "Shaft first critical speed (uniform, simply supported span) — result with checks and validity",
      "method": "Deterministic method shaft.critical_speed v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-08",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.3",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.3"
      ],
      "requirements": [
        "REQ-INT-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-09",
      "stage": "S5",
      "title": "Rejected option: one 10 m span with no steady bearings",
      "discipline": "mechanical",
      "deliverable": "Shaft first critical speed (uniform, simply supported span) — result with checks and validity",
      "method": "Deterministic method shaft.critical_speed v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-09",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.8",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.8"
      ],
      "requirements": [
        "REQ-SAFE-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-10",
      "stage": "S5",
      "title": "Parked extreme wind on rotor and tower",
      "discipline": "structural",
      "deliverable": "Rotor and tower wind thrust, base reactions — result with checks and validity",
      "method": "Deterministic method wind.thrust v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Structural engineer",
      "hours": 3,
      "calc": "CALC-10",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.2",
        "S5-CALC-01",
        "S5-CALC-10"
      ],
      "nodes": [
        "1.2.1"
      ],
      "requirements": [
        "REQ-LIFE-002"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S5-CALC-11",
      "stage": "S5",
      "title": "Top bearing life (weight + operating radial load) and static safety at extreme wind",
      "discipline": "mechanical",
      "deliverable": "Rolling bearing rating life (ISO 281 basic) and static safety — result with checks and validity",
      "method": "Deterministic method bearing.life v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-11",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.4",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.4.1"
      ],
      "requirements": [
        "REQ-LIFE-001"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S5-CALC-12",
      "stage": "S5",
      "title": "Speed-up stage pinion bending (screening)",
      "discipline": "mechanical",
      "deliverable": "Spur gear tooth bending (Lewis screening) — result with checks and validity",
      "method": "Deterministic method gear.lewis_bending v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-12",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.5",
        "S5-CALC-01"
      ],
      "nodes": [
        "1.5.1"
      ],
      "requirements": [
        "REQ-PERF-003"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-13",
      "stage": "S5",
      "title": "Clutch engagement onto a stationary generator",
      "discipline": "mechanical",
      "deliverable": "Clutch engagement: torque, slip energy and temperature rise — result with checks and validity",
      "method": "Deterministic method clutch.engagement v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-13",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.8",
        "S5-CALC-10"
      ],
      "nodes": [
        "1.8.2"
      ],
      "requirements": [
        "REQ-SAFE-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-14",
      "stage": "S5",
      "title": "Tower base flange bolts under parked extreme wind",
      "discipline": "mechanical",
      "deliverable": "Bolted joint: preload, tightening torque, separation and slip — result with checks and validity",
      "method": "Deterministic method bolt.joint v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Mechanical engineer",
      "hours": 3,
      "calc": "CALC-14",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9",
        "S5-CALC-10"
      ],
      "nodes": [
        "1.9.1"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-15",
      "stage": "S5",
      "title": "Spread footing: overturning, sliding, soil bearing",
      "discipline": "civil_geotech",
      "deliverable": "Square spread footing: overturning, sliding and soil bearing — result with checks and validity",
      "method": "Deterministic method foundation.spread_footing v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Civil / geotechnical engineer",
      "hours": 3,
      "calc": "CALC-15",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-DES-1.9",
        "S5-CALC-10"
      ],
      "nodes": [
        "1.9.3"
      ],
      "requirements": [
        "REQ-STR-001"
      ],
      "approval_gate": false,
      "risk": "high",
      "key": "S5-CALC-16",
      "stage": "S5",
      "title": "Anchor rods: steel strength under factored extreme wind",
      "discipline": "structural",
      "deliverable": "Anchor bolts on a bolt circle: tension and shear (steel strength) — result with checks and validity",
      "method": "Deterministic method anchor.bolt_circle v1.0.0; escalate to FEA/CFD/multibody if outside validity",
      "role": "Structural engineer",
      "hours": 3,
      "calc": "CALC-16",
      "acceptance": "Result recorded with inputs, version and fingerprint; mandatory checks pass or are escalated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "medium",
      "key": "S5-LC-04",
      "stage": "S5",
      "title": "Simulate Emergency stop from overspeed",
      "discipline": "controls",
      "deliverable": "Time-domain or spectrum result with assumptions",
      "method": "Time-domain drivetrain/controller simulation",
      "role": "Controls engineer",
      "hours": 16,
      "acceptance": "Brake applied at 1.3 × rated speed, generators disengaged"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "medium",
      "key": "S5-LC-06",
      "stage": "S5",
      "title": "Simulate Fatigue spectrum",
      "discipline": "mechanical",
      "deliverable": "Time-domain or spectrum result with assumptions",
      "method": "Load spectrum + Miner's rule; aeroelastic loads where justified",
      "role": "Mechanical engineer",
      "hours": 16,
      "acceptance": "20 years at the site distribution; 2P torque ripple on the shaft"
    },
    {
      "inputs": [],
      "depends_on": [
        "S3-PLAN"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "medium",
      "key": "S5-LC-07",
      "stage": "S5",
      "title": "Simulate Loss of grid / load rejection",
      "discipline": "controls",
      "deliverable": "Time-domain or spectrum result with assumptions",
      "method": "Time-domain drivetrain/controller simulation",
      "role": "Controls engineer",
      "hours": 16,
      "acceptance": "Electrical load drops to zero at rated; dump load and brake respond"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-CALC-01",
        "S5-CALC-02",
        "S5-CALC-03",
        "S5-CALC-04",
        "S5-CALC-05",
        "S5-CALC-06",
        "S5-CALC-07",
        "S5-CALC-08",
        "S5-CALC-09",
        "S5-CALC-10",
        "S5-CALC-11",
        "S5-CALC-12",
        "S5-CALC-13",
        "S5-CALC-14",
        "S5-CALC-15",
        "S5-CALC-16",
        "S5-LC-04",
        "S5-LC-06",
        "S5-LC-07"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-003",
        "REQ-PERF-004",
        "REQ-SAFE-001",
        "REQ-SAFE-002",
        "REQ-INT-001",
        "REQ-STR-001"
      ],
      "approval_gate": true,
      "risk": "high",
      "key": "S5-FEAS",
      "stage": "S5",
      "title": "Feasibility report",
      "discipline": "systems",
      "deliverable": "Feasibility verdict with best/base/worst cases, unknowns, validation plan and cost to resolve uncertainty",
      "method": "Classify per spec §06 from actual results; compare with baselines",
      "role": "Systems engineer",
      "hours": 10,
      "acceptance": "Verdict traceable to results; independent review requested for safety-critical items"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.1.3",
        "1.3.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-01",
      "stage": "S6",
      "title": "Define interface I-01: Rotor hub to top shaft segment: torque, weight and rotor bending moment",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.2",
        "1.8.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-02",
      "stage": "S6",
      "title": "Define interface I-02: Top bearing housing to tower top: radial rotor loads and weight into the tower",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.3.3",
        "1.3.4"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-04",
      "stage": "S6",
      "title": "Define interface I-04: Steady bearings to tower brackets: radial support only",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.3.1",
        "1.4.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-05",
      "stage": "S6",
      "title": "Define interface I-05: Shaft bottom to gearbox input (coupling, axial float allowance for thermal growth of the long shaft)",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.4.2",
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-06",
      "stage": "S6",
      "title": "Define interface I-06: Power take-off to each clutch",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.5.4",
        "1.5.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-08",
      "stage": "S6",
      "title": "Define interface I-08: Magnet driver command to each clutch; engagement state feedback",
      "discipline": "controls",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.5.2",
        "1.7.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-09",
      "stage": "S6",
      "title": "Define interface I-09: Generator AC to rectifiers / DC bus",
      "discipline": "controls",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.6.1",
        "1.7.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-10",
      "stage": "S6",
      "title": "Define interface I-10: Brake release / apply and overspeed trip",
      "discipline": "controls",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.8.3",
        "1.9.3"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-11",
      "stage": "S6",
      "title": "Define interface I-11: Base plate to anchor rods: tension, compression and shear",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.9.1",
        "1.9"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-12",
      "stage": "S6",
      "title": "Define interface I-12: Footing to soil: bearing pressure, sliding resistance",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS"
      ],
      "nodes": [
        "1.10.1",
        "1.5.2"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S6-I-13",
      "stage": "S6",
      "title": "Define interface I-13: Generator and gearbox heat rejected from the house",
      "discipline": "mechanical",
      "deliverable": "Interface control sheet: geometry, loads, fits, signals, ownership",
      "method": "Agree both sides; check compatibility",
      "role": "Systems engineer",
      "hours": 3,
      "acceptance": "Both owners sign; dependent calculations re-run"
    },
    {
      "inputs": [],
      "depends_on": [
        "S5-FEAS",
        "S6-I-01",
        "S6-I-02",
        "S6-I-04",
        "S6-I-05",
        "S6-I-06",
        "S6-I-08",
        "S6-I-09",
        "S6-I-10",
        "S6-I-11",
        "S6-I-12",
        "S6-I-13"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S6-TRADE",
      "stage": "S6",
      "title": "Optimization trade study",
      "discipline": "systems",
      "deliverable": "Recommended configuration (mass, cost, energy, reliability) with Pareto comparison",
      "method": "Vary geometry, materials, ratios and control thresholds; re-run impacted calculations",
      "role": "Systems engineer",
      "hours": 20,
      "acceptance": "Mandatory constraints hold in the recommended configuration"
    },
    {
      "inputs": [],
      "depends_on": [
        "S4-BOM",
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S7-COST",
      "stage": "S7",
      "title": "Cost model",
      "discipline": "cost",
      "deliverable": "NRE vs recurring cost; prototype, pilot and production scenarios; contingency",
      "method": "Roll up BOM, labour, tooling, testing, certification",
      "role": "Project controls",
      "hours": 8,
      "acceptance": "Quotes vs estimates labelled; currency, date, exclusions stated"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S7-SCOPES",
      "stage": "S7",
      "title": "Partner scopes",
      "discipline": "systems",
      "deliverable": "Scopes of work for: Aerodynamics and fluids, Structural, Electrical power, Electronics / PCB (VX Design), Controls and software, Civil and geotechnical, Manufacturing",
      "method": "Discipline handoff packages (spec §07)",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Each scope lists inputs, deliverables, standards and sign-off"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-COST",
        "S7-SCOPES"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S7-ROADMAP",
      "stage": "S7",
      "title": "Development roadmap and funding milestones",
      "discipline": "cost",
      "deliverable": "Schedule, budget per milestone, funding asks, contingencies",
      "method": "Sequence prototype → test → pilot; tie funding tranches to evidence",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Owner approves"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [
        "1.5.4",
        "1.7.1"
      ],
      "requirements": [],
      "approval_gate": false,
      "risk": "low",
      "key": "S8-VXD",
      "stage": "S8",
      "title": "VX Design electronics handoff",
      "discipline": "electronics",
      "deliverable": "Structured VX Design intake package",
      "method": "Export power budget, interfaces, environment, safety and EMC requirements",
      "role": "Systems engineer",
      "hours": 4,
      "acceptance": "VX Design accepts the intake without open questions"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-COST"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S8-RFQ",
      "stage": "S8",
      "title": "RFQ packages",
      "discipline": "sourcing",
      "deliverable": "Drawings, specs, quantities, tolerances, inspection and delivery requirements per supplier",
      "method": "Assemble from part records",
      "role": "Buyer",
      "hours": 8,
      "acceptance": "Owner approves before any external disclosure"
    },
    {
      "inputs": [],
      "depends_on": [
        "S6-TRADE"
      ],
      "nodes": [],
      "requirements": [
        "REQ-PERF-001",
        "REQ-PERF-002",
        "REQ-SAFE-002",
        "REQ-SAFE-003",
        "REQ-MAINT-001",
        "REQ-ENV-002",
        "REQ-REG-001",
        "REQ-REG-002"
      ],
      "approval_gate": false,
      "risk": "low",
      "key": "S8-TESTPLAN",
      "stage": "S8",
      "title": "Prototype instrumentation and test plan",
      "discipline": "testing",
      "deliverable": "Test procedures for 8 requirements verified by test/inspection/demonstration",
      "method": "One procedure per requirement; instrumentation list; pass criteria",
      "role": "Test engineer",
      "hours": 16,
      "acceptance": "Every test-verified requirement has a procedure and pass criterion"
    },
    {
      "inputs": [],
      "depends_on": [
        "S7-ROADMAP",
        "S8-RFQ",
        "S8-TESTPLAN",
        "S8-VXD"
      ],
      "nodes": [],
      "requirements": [],
      "approval_gate": true,
      "risk": "low",
      "key": "S8-PACKAGE",
      "stage": "S8",
      "title": "Funding-ready preliminary package",
      "discipline": "systems",
      "deliverable": "Brief, requirements, structure, BOM, calcs, feasibility, risks, costs, roadmap — marked preliminary",
      "method": "Assemble and export; no certification or construction-readiness claims",
      "role": "Project lead",
      "hours": 6,
      "acceptance": "Reviewer approval status shown on every document"
    }
  ],
  "cost": {
    "currency": "USD",
    "date": "2026-11-25",
    "bom": [
      {
        "id": "1.1.1",
        "name": "Blades (H-rotor, pultruded aerofoil)",
        "qty": 3,
        "make_buy": "make",
        "low": 900,
        "high": 2400,
        "basis": "assumed"
      },
      {
        "id": "1.1.2",
        "name": "Blade struts / arms",
        "qty": 6,
        "make_buy": "make",
        "low": 600,
        "high": 1500,
        "basis": "assumed"
      },
      {
        "id": "1.1.3",
        "name": "Rotor hub",
        "qty": 1,
        "make_buy": "make",
        "low": 500,
        "high": 1400,
        "basis": "assumed"
      },
      {
        "id": "1.1.4",
        "name": "Blade and strut fasteners",
        "qty": 36,
        "make_buy": "buy",
        "low": 80,
        "high": 200,
        "basis": "assumed"
      },
      {
        "id": "1.2.1",
        "name": "Top radial bearing (spherical roller)",
        "qty": 1,
        "make_buy": "buy",
        "low": 150,
        "high": 450,
        "basis": "assumed"
      },
      {
        "id": "1.2.2",
        "name": "Thrust bearing carrying rotor and shaft weight",
        "qty": 1,
        "make_buy": "buy",
        "low": 200,
        "high": 600,
        "basis": "assumed"
      },
      {
        "id": "1.2.3",
        "name": "Bearing housing, seals and lubrication",
        "qty": 1,
        "make_buy": "make",
        "low": 300,
        "high": 900,
        "basis": "assumed"
      },
      {
        "id": "1.3.1",
        "name": "Shaft segments",
        "qty": 3,
        "make_buy": "make",
        "low": 900,
        "high": 2200,
        "basis": "assumed"
      },
      {
        "id": "1.3.2",
        "name": "Segment couplings (disc type)",
        "qty": 2,
        "make_buy": "buy",
        "low": 400,
        "high": 1200,
        "basis": "assumed"
      },
      {
        "id": "1.3.3",
        "name": "Intermediate steady bearings",
        "qty": 2,
        "make_buy": "buy",
        "low": 120,
        "high": 400,
        "basis": "assumed"
      },
      {
        "id": "1.3.4",
        "name": "Steady-bearing brackets in tower",
        "qty": 2,
        "make_buy": "make",
        "low": 150,
        "high": 400,
        "basis": "assumed"
      },
      {
        "id": "1.4.1",
        "name": "Speed-up gearbox (planetary or helical)",
        "qty": 1,
        "make_buy": "buy",
        "low": 1200,
        "high": 3500,
        "basis": "assumed"
      },
      {
        "id": "1.4.2",
        "name": "Power take-off to generator branches",
        "qty": 1,
        "make_buy": "make",
        "low": 800,
        "high": 2500,
        "basis": "assumed"
      },
      {
        "id": "1.4.3",
        "name": "Gearbox lubricant",
        "qty": 1,
        "make_buy": "buy",
        "low": 60,
        "high": 150,
        "basis": "assumed"
      },
      {
        "id": "1.5.1",
        "name": "Magnetically controlled centrifugal clutches",
        "qty": 3,
        "make_buy": "make",
        "low": 900,
        "high": 3000,
        "basis": "assumed"
      },
      {
        "id": "1.5.2",
        "name": "Permanent-magnet generators 1.5 kW",
        "qty": 3,
        "make_buy": "buy",
        "low": 1200,
        "high": 3000,
        "basis": "assumed"
      },
      {
        "id": "1.5.3",
        "name": "Generator couplings (jaw)",
        "qty": 3,
        "make_buy": "buy",
        "low": 120,
        "high": 300,
        "basis": "assumed"
      },
      {
        "id": "1.5.4",
        "name": "Clutch magnet drivers and engagement controller",
        "qty": 1,
        "make_buy": "make",
        "low": 400,
        "high": 1500,
        "basis": "assumed"
      },
      {
        "id": "1.6.1",
        "name": "Spring-applied fail-safe brake",
        "qty": 1,
        "make_buy": "buy",
        "low": 400,
        "high": 1200,
        "basis": "assumed"
      },
      {
        "id": "1.6.2",
        "name": "Redundant overspeed sensing",
        "qty": 2,
        "make_buy": "buy",
        "low": 150,
        "high": 500,
        "basis": "assumed"
      },
      {
        "id": "1.7.1",
        "name": "Supervisory controller",
        "qty": 1,
        "make_buy": "make",
        "low": 500,
        "high": 2000,
        "basis": "assumed"
      },
      {
        "id": "1.7.2",
        "name": "Rectifiers, DC bus and listed hybrid inverter",
        "qty": 1,
        "make_buy": "buy",
        "low": 1500,
        "high": 4000,
        "basis": "assumed"
      },
      {
        "id": "1.7.3",
        "name": "Dump load / diversion resistor",
        "qty": 1,
        "make_buy": "buy",
        "low": 100,
        "high": 300,
        "basis": "assumed"
      },
      {
        "id": "1.7.4",
        "name": "Sensors: anemometer, shaft speed/torque, vibration, temperatures",
        "qty": 1,
        "make_buy": "buy",
        "low": 600,
        "high": 2500,
        "basis": "assumed"
      },
      {
        "id": "1.7.5",
        "name": "Enclosures, disconnects, wiring and earthing",
        "qty": 1,
        "make_buy": "buy",
        "low": 500,
        "high": 1500,
        "basis": "assumed"
      },
      {
        "id": "1.8.1",
        "name": "Tubular steel tower, flanged sections",
        "qty": 1,
        "make_buy": "make",
        "low": 2500,
        "high": 6000,
        "basis": "assumed"
      },
      {
        "id": "1.8.2",
        "name": "Tower base flange bolts (M24, class 10.9)",
        "qty": 16,
        "make_buy": "buy",
        "low": 100,
        "high": 300,
        "basis": "assumed"
      },
      {
        "id": "1.8.3",
        "name": "Tower base plate",
        "qty": 1,
        "make_buy": "make",
        "low": 300,
        "high": 900,
        "basis": "assumed"
      },
      {
        "id": "1.8.4",
        "name": "Service access: hatch, climbing / tower-lowering provision",
        "qty": 1,
        "make_buy": "make",
        "low": 400,
        "high": 2500,
        "basis": "assumed"
      },
      {
        "id": "1.9.1",
        "name": "Reinforced-concrete spread footing",
        "qty": 1,
        "make_buy": "make",
        "low": 2500,
        "high": 6000,
        "basis": "assumed"
      },
      {
        "id": "1.9.2",
        "name": "Reinforcement",
        "qty": 1,
        "make_buy": "buy",
        "low": 400,
        "high": 1200,
        "basis": "assumed"
      },
      {
        "id": "1.9.3",
        "name": "Anchor rods (M30, F1554 Gr 55) and setting template",
        "qty": 12,
        "make_buy": "buy",
        "low": 300,
        "high": 900,
        "basis": "assumed"
      },
      {
        "id": "1.9.4",
        "name": "Base-plate grout",
        "qty": 1,
        "make_buy": "buy",
        "low": 50,
        "high": 150,
        "basis": "assumed"
      },
      {
        "id": "1.9.5",
        "name": "Earthing electrode and lightning protection",
        "qty": 1,
        "make_buy": "buy",
        "low": 200,
        "high": 800,
        "basis": "assumed"
      },
      {
        "id": "1.10.1",
        "name": "Weatherproof generator house",
        "qty": 1,
        "make_buy": "make",
        "low": 1000,
        "high": 3500,
        "basis": "assumed"
      },
      {
        "id": "1.10.2",
        "name": "Guards on rotating parts",
        "qty": 1,
        "make_buy": "make",
        "low": 200,
        "high": 700,
        "basis": "assumed"
      },
      {
        "id": "1.10.3",
        "name": "Lifting points and generator slide rails",
        "qty": 1,
        "make_buy": "make",
        "low": 200,
        "high": 600,
        "basis": "assumed"
      }
    ],
    "lines": [
      {
        "label": "Parts and materials (BOM roll-up)",
        "low": 20880,
        "high": 61150,
        "kind": "recurring",
        "basis": "estimates — not quotes"
      },
      {
        "label": "Assembly, inspection and freight (15 % of parts)",
        "low": 3132,
        "high": 9172.5,
        "kind": "recurring",
        "basis": "rule of thumb"
      },
      {
        "label": "Engineering (610 h from the plan at $120/h, ±30 %)",
        "low": 51240,
        "high": 95160,
        "kind": "nre",
        "basis": "plan estimate"
      },
      {
        "label": "Prototype testing and instrumentation",
        "low": 10440,
        "high": 61150,
        "kind": "nre",
        "basis": "allowance: 50–100 % of one unit's parts"
      },
      {
        "label": "Independent specialist review (structural, geotechnical, mechanical)",
        "low": 4000,
        "high": 15000,
        "kind": "nre",
        "basis": "allowance"
      },
      {
        "label": "Permits and site work",
        "low": 1500,
        "high": 8000,
        "kind": "nre",
        "basis": "allowance; jurisdiction-dependent"
      },
      {
        "label": "Certification path (pre-assessment; full certification excluded)",
        "low": 5000,
        "high": 25000,
        "kind": "nre",
        "basis": "allowance"
      }
    ],
    "nre": {
      "low": 90225,
      "high": 255387.5
    },
    "unit": {
      "low": 24011.999999999996,
      "high": 70322.5
    },
    "scenarios": [
      {
        "name": "Prototype",
        "units": 1,
        "unit_low": 24011.999999999996,
        "unit_high": 70322.5,
        "total_low": 114237,
        "total_high": 325710
      },
      {
        "name": "Pilot",
        "units": 10,
        "unit_low": 13994.683500671072,
        "unit_high": 40985.387742626255,
        "total_low": 139946.83500671072,
        "total_high": 409853.87742626254
      },
      {
        "name": "Production",
        "units": 100,
        "unit_low": 8156.387068297317,
        "unit_high": 23887.12017367725,
        "total_low": 815638.7068297317,
        "total_high": 2388712.017367725
      }
    ],
    "assumptions": [
      "Engineering rate $120/h",
      "Contingency 25 % on NRE",
      "Learning curve 85 % per doubling (applied to unit cost)",
      "Part costs are estimates unless marked supplier_data"
    ],
    "exclusions": [
      "Full certification testing",
      "Land, grid-connection fees",
      "Taxes and duties",
      "Patent prosecution",
      "Operating and maintenance costs (reported separately once a duty cycle is agreed)"
    ]
  }
}