  "schema": "vx-design-intake/1",
  "source": {
    "product": "VX Inventor",
    "project": "Vertical-transmission wind turbine",
    "exported": "2026-11-25T06:31:08.025Z"
  },
  "status": "preliminary",
  "summary": "Vertical-transmission wind turbine: A wind rotor drives a vertical shaft down the tower to staged, clutch-engaged generators at ground level.",
  "boards": [
    {
      "ref": "1.5.4",
      "name": "Clutch magnet drivers and engagement controller",
      "function": "Implements engagement thresholds and hysteresis; fails to a safe state",
      "notes": "Routed to VX Design through the electronics handoff"
    },
    {
      "ref": "1.7.1",
      "name": "Supervisory controller",
      "function": "State machine verified in simulation and on the test rig",
      "notes": "Routed to VX Design"
    }
  ],
  "interfaces": [
    {
      "id": "I-08",
      "kind": "signal",
      "between": [
        "Clutch magnet drivers and engagement controller",
        "Magnetically controlled centrifugal clutches"
      ],
      "description": "Magnet driver command to each clutch; engagement state feedback",
      "defined": false
    },
    {
      "id": "I-09",
      "kind": "electrical",
      "between": [
        "Permanent-magnet generators 1.5 kW",
        "Rectifiers, DC bus and listed hybrid inverter"
      ],
      "description": "Generator AC to rectifiers / DC bus",
      "defined": false
    },
    {
      "id": "I-10",
      "kind": "signal",
      "between": [
        "Spring-applied fail-safe brake",
        "Supervisory controller"
      ],
      "description": "Brake release / apply and overspeed trip",
      "defined": false
    }
  ],
  "power_budget": [
    {
      "source": "CALC-01 Rotor shaft power",
      "value": 3.8102,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 Rotor shaft power",
      "value": 0.47628,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-04 Electrical output (staged)",
      "value": 3.2712,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-05 Electrical output (staged)",
      "value": 0.35719,
      "unit": "kW",
      "basis": "calculated from assumptions"
    }
  ],
  "environment": [
    "Outdoor, rural/suburban site, −20 to +45 °C, corrosivity C3, IEC small-wind class III (assumed).",
    "REQ-ENV-001: −20 to +45 °C; ISO 12944 C3; enclosures IP54 min",
    "REQ-ENV-002: ≤ local limit (typ. 45 dB(A) at night)"
  ],
  "safety": [
    "REQ-SAFE-001: Survive the 50-year extreme wind parked without structural failure. (Ve50 = 52.5 m/s (IEC 61400-2 class III))",
    "REQ-SAFE-002: A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid. (stop from 1.3× rated speed; PL c or better (ISO 13849))",
    "REQ-SAFE-003: All rotating parts accessible at ground level shall be guarded. (ISO 12100 / ISO 13857 distances)",
    "REQ-STR-001: The foundation shall resist overturning and sliding and stay within allowable soil bearing. (FS ≥ 1.5 overturning and sliding; q ≤ q_allow)"
  ],
  "standards": [
    {
      "id": "IEC 60204-1",
      "title": "Safety of machinery — Electrical equipment of machines"
    },
    {
      "id": "IEC 61000 series",
      "title": "Electromagnetic compatibility"
    },
    {
      "id": "ISO 13849-1/-2",
      "title": "Safety of machinery — Safety-related parts of control systems"
    },
    {
      "id": "IEC 60529",
      "title": "Degrees of protection provided by enclosures (IP code)"
    }
  ],
  "requirements": [
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the 50-year extreme wind parked without structural failure.",
      "target": "Ve50 = 52.5 m/s (IEC 61400-2 class III)"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid.",
      "target": "stop from 1.3× rated speed; PL c or better (ISO 13849)"
    },
    {
      "code": "REQ-SAFE-003",
      "text": "All rotating parts accessible at ground level shall be guarded.",
      "target": "ISO 12100 / ISO 13857 distances"
    },
    {
      "code": "REQ-INT-001",
      "text": "The vertical shaft shall run clear of its bending critical speeds.",
      "target": "critical / max running speed ≥ 1.25"
    },
    {
      "code": "REQ-STR-001",
      "text": "The foundation shall resist overturning and sliding and stay within allowable soil bearing.",
      "target": "FS ≥ 1.5 overturning and sliding; q ≤ q_allow"
    },
    {
      "code": "REQ-REG-001",
      "text": "Follow a recognised small-wind certification path.",
      "target": "IEC 61400-2 or ANSI/ACP 101-1"
    },
    {
      "code": "REQ-REG-002",
      "text": "Grid-connected operation shall use listed interconnection equipment.",
      "target": "UL 1741 / IEEE 1547"
    }
  ],
  "open_questions": [
    "G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?"
  ]
}