Library / Methods / bolt.joint
Bolted joint: preload, tightening torque, separation and slip
Metric bolt group under external tension and shear: preload from the proof load, tightening torque, load factor against proof, separation and friction-grip slip.
bolt.jointversion 1.0.01/1 reference cases verified now
Result with default inputs
pass| Tensile stress area As | 156.7 mm² |
| Proof load per bolt | 90.87 kN |
| Preload per bolt | 68.15 kN |
| Tightening torque | 218.1 N·m |
| Load factor n_L | 12.12 |
| Separation factor n_0 | 12.12 |
| Slip factor | 7.503 |
Checks
| bolt load within proof (load factor) | 12.1 ≥ 1.2 | pass |
| joint separation | 12.1 ≥ 1.2 | pass |
| slip (friction grip) | 7.5 ≥ 1.2 | pass |
Equations
As = π/4·(d − 0.9382·p)², Fp = Sp·As, Fi = k·Fp
T = K·Fi·d
n_L = (Sp·As − Fi)/(C·P), n_0 = Fi/(P·(1 − C))
n_slip = μ·n·Fi / V (tension reduces clamp: Fi − (1−C)·P)
Sources
- ISO 898-1 (property classes)
- ISO 261/724 (thread dimensions)
- Shigley 10th ed., §8-7 to 8-9
- VDI 2230 for a full joint analysis
Standards
Assumptions
- Load shared equally by the bolts
- Joint stiffness fraction C from the joint geometry (typically 0.15–0.35)
- Nut factor K = 0.2 for plain dry steel
Validity limits
- Static loads; fatigue of bolts under alternating loads needs a separate check (VDI 2230 / Shigley §8-11)
Reference cases
| Case | Expected | Reference | |
|---|---|---|---|