VX Inventor
Sign in

Library / Methods / bolt.joint

Bolted joint: preload, tightening torque, separation and slip

Metric bolt group under external tension and shear: preload from the proof load, tightening torque, load factor against proof, separation and friction-grip slip.

bolt.jointversion 1.0.01/1 reference cases verified now

Run it

Result with default inputs

pass
Tensile stress area As156.7 mm²
Proof load per bolt90.87 kN
Preload per bolt68.15 kN
Tightening torque218.1 N·m
Load factor n_L12.12
Separation factor n_012.12
Slip factor7.503

Checks

bolt load within proof (load factor)12.1 ≥ 1.2pass
joint separation12.1 ≥ 1.2pass
slip (friction grip)7.5 ≥ 1.2pass

Equations

As = π/4·(d − 0.9382·p)², Fp = Sp·As, Fi = k·Fp
T = K·Fi·d
n_L = (Sp·As − Fi)/(C·P), n_0 = Fi/(P·(1 − C))
n_slip = μ·n·Fi / V (tension reduces clamp: Fi − (1−C)·P)

Sources

  • ISO 898-1 (property classes)
  • ISO 261/724 (thread dimensions)
  • Shigley 10th ed., §8-7 to 8-9
  • VDI 2230 for a full joint analysis

Standards

ISO 898-1VDI 2230 Part 1

Assumptions

  • Load shared equally by the bolts
  • Joint stiffness fraction C from the joint geometry (typically 0.15–0.35)
  • Nut factor K = 0.2 for plain dry steel

Validity limits

  • Static loads; fatigue of bolts under alternating loads needs a separate check (VDI 2230 / Shigley §8-11)

Reference cases

CaseExpectedReference
M12 8.8as = 84.267, fp = 48.875, torque = 87.975ISO 898-1: As(M12) = 84.3 mm², proof 580 MPa; T = 0.2·36.66 kN·12 mmverified