Library / Methods / column.buckling
Column buckling (Euler, with Johnson for short columns)
Critical axial load of a tube or solid column (a vertical shaft carrying the rotor's weight, a tower leg).
column.bucklingversion 1.0.01/1 reference cases verified now
Result with default inputs
pass| Slenderness K·L/r | 400 |
| Critical load | 34.88 kN |
| Euler (slender) | 106.2 |
Checks
| buckling | 6.98 ≥ 1.2 | pass |
Equations
Pcr = π²·E·I / (K·L)² (slender)
Johnson: Pcr = A·(Sy − (Sy·K·L/(2π·r))² / E) when K·L/r < √(2π²E/Sy)
Sources
- Shigley 10th ed., §4-11 to 4-13
- AISC 360 ch. E governs steel compression members in buildings
Standards
Assumptions
- Straight, centrally loaded member; initial crookedness and eccentric load reduce capacity
Validity limits
- Code design (AISC 360, Eurocode 3) applies resistance factors; this is the theoretical critical load
Reference cases
| Case | Expected | Reference | |
|---|---|---|---|
| 50 mm solid, 2 m pinned | p_cr = 151.4 | hand: π²·200e9·3.068e-7/4 = 151.4 kN | verified |