Staged multi-generator drivetrain: energy balance

Shaft power through a gear stage and bearings into N generators that are engaged one at a time as power rises (clutch staging). Compares the staged arrangement with one generator of the same total rating, and proves the energy balance closes.

drivetrain.staged_generatorsversion 1.0.02/2 reference cases verified now

Run it

Result with default inputs

pass
Power at generator shaft2.83 kW
Generators engaged3
Load on each engaged generator62.89 %
Electrical output (staged)2.557 kW
Electrical output (one generator of the same total rating)2.557 kW
Gain from staging at this point0 kW
Gear loss0.12 kW
Bearing + seal loss0.05 kW
Generator losses0.2732 kW
Power shed (above installed rating)0 kW
Rotor-to-electrical efficiency85.23 %
Generator speed1,440 rpm
Torque on each generator shaft6.256 N·m
Energy balance residual0 kW

Equations

P_shaft = P_rotor · η_gear − P_bearings
engaged n = min(N, ⌈P_shaft / (f_engage · P_gen)⌉)
generator loss = L_fixed + L_load · (P_in / P_gen)², L_rated = (1 − η_gen) · P_gen
P_rotor = P_elec + Σ losses + P_curtailed (must close)

Sources

  • IEC 60034-2-1 (loss segregation of rotating machines)
  • Generator loss model: fixed + load-dependent losses

Standards

IEC 60034-1/-2-1

Assumptions

  • Generators share shaft power equally when engaged
  • Fixed losses apply only to engaged generators (clutch disengaged = no drag)
  • Clutch slip losses during engagement are transient and handled by the clutch method

Validity limits

  • Steady state at one operating point; run across the power curve for annual energy

Reference cases

CaseExpectedReference
Low wind: one of three generators engaged, beats one big generatorengaged = 1, p_shaft = 0.748, balance_residual = 0hand: 0.8·0.96 − 0.02 = 0.748 kW < 0.8·1.5verified
Above installed rating: power is shed, not createdengaged = 3, curtailed = 5.5hand: 10 − 3·1.5verified