Square spread footing: overturning, sliding and soil bearing

A square reinforced-concrete pad under a tower: the stabilising weight, factors of safety against overturning and sliding, eccentricity and peak soil pressure.

foundation.spread_footingversion 1.0.01/1 reference cases verified now

Run it

Result with default inputs

fail
Footing weight169.9 kN
Soil cover weight81 kN
Total stabilising vertical load310.9 kN
Overturning moment at base332.5 kN·m
Eccentricity1.069 m
Peak soil pressure160.5 kPa
Minimum soil pressure0 kPa
Concrete volume7.2 m³

Checks

overturning1.4 ≥ 1.5FAIL
sliding5.6 ≥ 1.5pass
soil bearing0.935 ≥ 1FAIL
  • eccentricity 1.07 m exceeds B/6 = 0.50 m: part of the base lifts off the soil (allowed by some codes for wind, not for sustained loads)
  • Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)

Equations

W = V + γc·B²·D + γs·B²·h
M_ot = M + H·(D + h); FS_ot = W·(B/2) / M_ot
FS_sl = μ·W / H
e = M_ot / W; q_max = W/B²·(1 + 6e/B) for e ≤ B/6, else 2W / (3B·(B/2 − e))

Sources

  • Das, Principles of Foundation Engineering, ch. 6
  • ACI 318 ch. 13 (foundations)
  • ASCE 7 §2.4 (allowable-stress load combinations)

Standards

ACI 318ASCE/SEI 7International Building Code (as adopted locally)

Assumptions

  • Loads given are unfactored service loads at the top of the pedestal (grade level)
  • Soil cover over the footing counts as stabilising weight
  • Allowable bearing pressure already includes the geotechnical factor of safety

Validity limits

  • Rigid footing on uniform soil; no uplift on the heel beyond e = B/2
  • Required factors (typically 1.5) are replaced by the governing code combinations in final design

Reference cases

CaseExpectedReference
3 m pad, large moment (partial uplift)w_total = 353.8, m_ot = 326, e = 0.92143, q_max = 135.88hand: W = 100 + 172.8 + 81; e = 326/353.8 > B/6; q = 2·353.8/(3·3·(1.5 − 0.9214))verified