VX Inventor
Sign in

Library / Methods / solar.pv_output

Photovoltaic array output and annual yield

DC and AC output of a PV array at a given irradiance and temperature, and annual energy from peak sun hours.

solar.pv_outputversion 1.0.01/1 reference cases verified now

Run it

Result with default inputs

pass
Cell temperature56.25 °C
Rated DC power at STC2.1 kW
DC output at this condition1.87 kW
AC output at this condition1.609 kW
Annual energy (estimate)2,642 kWh
Specific yield1,258 kWh

Equations

T_cell = T_amb + (NOCT − 20)·G/800
P_dc = G·C·A·η·(1 + γ·(T_cell − 25))
P_ac = P_dc·(1 − losses)
E_year = 1000·A·η·PSH·365·(1 − losses)·(1 + γ·(T_cell,avg − 25))

Sources

  • IEC 61215 / IEC 61853 (module rating, NOCT)
  • Duffie & Beckman, Solar Engineering of Thermal Processes, ch. 23

Standards

IEC 61215IEC 61730 / UL 61730

Assumptions

  • Module efficiency at STC (1000 W/m², 25 °C)
  • Concentration ratio C applies optical concentration (1 for flat panels)

Validity limits

  • Single-junction silicon modules: η ≤ 0.26; above that the cell technology must be stated
  • Irradiance on the cells above 1361 W/m² requires concentration

Reference cases

CaseExpectedReference
10 m² at 20%, 1000 W/m², 25 °C ambientt_cell = 56.25, p_dc = 1.78125, p_ac = 1.531875hand: Tc = 25 + 25·1.25; 2000·(1 − 0.0035·31.25)verified