Annual energy production (Weibull site)
Annual energy from a Weibull wind-speed distribution and a power curve with cut-in, rated and cut-out speeds.
wind.annual_energyversion 1.0.01/1 reference cases verified now
Result with default inputs
pass| Weibull scale c | 6.77 m/s |
| Rated rotor power | 3.81 kW |
| Mean electrical power | 0.6588 kW |
| Annual energy production | 5,771 kWh |
| Capacity factor (of rated electrical) | 20.34 % |
| Hours between cut-in and cut-out | 7,198 h |
Equations
f(v) = (k/c)(v/c)^(k−1) · exp(−(v/c)^k), c = v̄ / Γ(1 + 1/k)
P(v) = min(½ρAv³Cp, P_rated) for v_in ≤ v < v_out, else 0
AEP = 8760 h · η_elec · availability · ∫ P(v) f(v) dv
Sources
- IEC 61400-12-1 (power performance)
- Manwell et al., Wind Energy Explained, ch. 2 and 3
Standards
Assumptions
- Hub-height mean wind speed from site data (not regional maps) once available
- Constant Cp below rated (real rotors vary with tip-speed ratio)
Validity limits
- k between 1.2 and 4 covers almost all sites; k = 2 is the Rayleigh distribution
Reference cases
| Case | Expected | Reference | |
|---|---|---|---|
| Rayleigh 6 m/s, no rated limit, mean of v³ | aep = 6640.3 | closed form: E[v³] = c³·Γ(1+3/k) = 412.5 m³/s³; 0.5·1.225·10·0.3·412.5·8.76 (tail above 59 m/s negligible) | verified |