Library / Methods / wind.rotor_power
Wind rotor power, speed and torque
Power captured by a rotor from the wind, the rotor speed from its tip-speed ratio and the shaft torque.
wind.rotor_powerversion 1.0.02/2 reference cases verified now
Result with default inputs
pass| Swept area | 12 m² |
| Power in the wind (Cp = 1) | 12.7 kW |
| Rotor shaft power | 3.81 kW |
| Rotor speed | 229.2 rpm |
| Rotor shaft torque | 158.8 N·m |
Equations
P = ½ · ρ · A · v³ · Cp
A = D · H (vertical axis) or π·D²/4 (horizontal axis)
ω = λ · v / R
T = P / ω
Sources
- Manwell, McGowan & Rogers, Wind Energy Explained, 2nd ed., ch. 3
- Betz limit Cp ≤ 16/27
Standards
Assumptions
- Steady, uniform wind across the swept area
- Cp is the rotor's power coefficient at this tip-speed ratio (from test or a validated aerodynamic model)
Validity limits
- Cp cannot exceed the Betz limit 0.593
- Below cut-in and above rated speed the control strategy governs, not this equation
Reference cases
| Case | Expected | Reference | |
|---|---|---|---|
| HAWT 10 m, 10 m/s, Cp 0.4 | p_rotor = 19.2423, area = 78.5398 | hand calculation: 0.5 × 1.225 × 78.54 × 1000 × 0.4 | verified |
| VAWT 3 × 4 m, 12 m/s, Cp 0.3 | p_rotor = 3.81024, rpm = 229.183 | hand calculation: 0.5 × 1.225 × 12 × 1728 × 0.3; ω = 3·12/1.5 = 24 rad/s | verified |