VX Inventor
Sign in

Library / Methods / wind.rotor_power

Wind rotor power, speed and torque

Power captured by a rotor from the wind, the rotor speed from its tip-speed ratio and the shaft torque.

wind.rotor_powerversion 1.0.02/2 reference cases verified now

Run it

Result with default inputs

pass
Swept area12 m²
Power in the wind (Cp = 1)12.7 kW
Rotor shaft power3.81 kW
Rotor speed229.2 rpm
Rotor shaft torque158.8 N·m

Equations

P = ½ · ρ · A · v³ · Cp
A = D · H (vertical axis) or π·D²/4 (horizontal axis)
ω = λ · v / R
T = P / ω

Sources

  • Manwell, McGowan & Rogers, Wind Energy Explained, 2nd ed., ch. 3
  • Betz limit Cp ≤ 16/27

Standards

IEC 61400-2IEC 61400-12-1

Assumptions

  • Steady, uniform wind across the swept area
  • Cp is the rotor's power coefficient at this tip-speed ratio (from test or a validated aerodynamic model)

Validity limits

  • Cp cannot exceed the Betz limit 0.593
  • Below cut-in and above rated speed the control strategy governs, not this equation

Reference cases

CaseExpectedReference
HAWT 10 m, 10 m/s, Cp 0.4p_rotor = 19.2423, area = 78.5398hand calculation: 0.5 × 1.225 × 78.54 × 1000 × 0.4verified
VAWT 3 × 4 m, 12 m/s, Cp 0.3p_rotor = 3.81024, rpm = 229.183hand calculation: 0.5 × 1.225 × 12 × 1728 × 0.3; ω = 3·12/1.5 = 24 rad/sverified