Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.

Gaps, assumptions and findings

The agent never silently invents dimensions, loads, allowables or supplier data: what is missing is a gap (blocking, assumable with bounded sensitivity, or deferred), and what is assumed says so.

Open questions

CodeQuestionClassDisciplineWhy it matters
G-01Import the patent / design documents for the vertical transmission and the staged clutch arrangement.blockingSystems engineeringArchitecture (rotor type, power take-off layout, clutch mechanism) cannot be locked without them.
G-02Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?
Proposed: A-01: vertical-axis H-rotor
blockingAerodynamics and fluidsChanges rotor loads, yaw system, top gearbox and every downstream calculation.
G-03Where will the prototype stand? Site wind data (or a nearby met station) and the permitting authority.
Proposed: A-03 and A-04
assumableAerodynamics and fluidsAEP, extreme wind class and code jurisdiction depend on the site.
G-04Geotechnical report: allowable bearing, friction, frost depth, water table.
Proposed: A-07: 150 kPa
assumableCivil and geotechnicalFoundation size is sensitive to soil; preliminary sizing may assume, construction may not.
G-05How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?
Proposed: A-11
blockingMechanical / machine designSets the engagement law, slip energy and the controller design.
G-06Which generators: maker, rated speed, efficiency map, inertia?
Proposed: A-05, A-06
assumableElectrical powerPart-load efficiency is the whole case for staging; it must come from measured maps.
G-07Grid-tied, battery-based or both?deferredElectrical powerSelects the inverter and the interconnection standards; does not change the mechanical design.
G-08Prototype budget and the funding target.blockingCost and fundingScopes the prototype and test plan.
G-09Local noise and setback limits.deferredStandards and compliancePermitting condition, usually settled at site selection.

Assumptions

CodeAssumptionValueSensitivityAffectsStatus
A-01Rotor is a 3-blade H-type vertical-axis rotor, 3 m diameter × 4 m high, on top of the tower.D 3 m, H 4 m, A 12 m²high1.1, 1.2, 1.8, 1.9unapproved
A-02Rotor power coefficient Cp = 0.30 at tip-speed ratio 3 (mid-range of published H-rotor tests).Cp 0.30, λ 3high1.1, 1.5unapproved
A-03Site wind: annual mean 6 m/s at rotor height, Rayleigh distribution (no site data yet).6 m/s, k = 2high1.1unapproved
A-04IEC 61400-2 class III: Vref 37.5 m/s, 50-year extreme Ve50 = 52.5 m/s.Ve50 52.5 m/smedium1.8, 1.9unapproved
A-05Three 1.5 kW permanent-magnet generators behind a 6.5:1 speed-up stage.3 × 1.5 kW, 6.5:1high1.4, 1.5unapproved
A-06Generator losses: 10 % at rated, 35 % of that fixed (core, friction, windage).η 0.90, fixed share 0.35medium1.5unapproved
A-07Allowable soil bearing 150 kPa, friction 0.45 (no geotechnical report).150 kPahigh1.9unapproved
A-08Rotor centre 10 m above grade; tower Ø 0.4 m × 8 m.10 mmedium1.3, 1.8, 1.9unapproved
A-09Shaft: solid Ø 60 mm AISI 4140 Q&T in three segments; torque ripple ±50 % of mean (2-blade-pass excitation of a VAWT).Ø 60 mm, ripple 0.5medium1.3unapproved
A-10Parked rotor drag coefficient 1.2 on projected area (conservative).C_T 1.2medium1.8, 1.9unapproved
A-11Clutch: a centrifugal shoe clutch whose engagement is held off or released by an electromagnet, so a controller can set the engagement threshold by power.—high1.5.1, 1.5.4unapproved

Design review findings

Blocking 4
Warnings 19
Information 38