VX Inventor
Sign in

Reference projects / Vertical-transmission wind turbineConditional feasibility

Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.

Handoffs and exports

Discipline packages (spec §07). Electronics goes to VX Design as a structured intake package; every other discipline gets a scope with its inputs, standards, deliverables and open questions. Nothing is sent outside without your approval.

VX Design electronics intake

vx-design-intake/1Download for VX Design

2 board(s) · 3 interface(s) · 4 power figures · 4 standards · 1 open question(s)

Preview the package
{
  "schema": "vx-design-intake/1",
  "source": {
    "product": "VX Inventor",
    "project": "Vertical-transmission wind turbine",
    "exported": "preview"
  },
  "status": "preliminary",
  "summary": "Vertical-transmission wind turbine: A wind rotor drives a vertical shaft down the tower to staged, clutch-engaged generators at ground level.",
  "boards": [
    {
      "ref": "1.5.4",
      "name": "Clutch magnet drivers and engagement controller",
      "function": "Implements engagement thresholds and hysteresis; fails to a safe state",
      "notes": "Routed to VX Design through the electronics handoff"
    },
    {
      "ref": "1.7.1",
      "name": "Supervisory controller",
      "function": "State machine verified in simulation and on the test rig",
      "notes": "Routed to VX Design"
    }
  ],
  "interfaces": [
    {
      "id": "I-08",
      "kind": "signal",
      "between": [
        "Clutch magnet drivers and engagement controller",
        "Magnetically controlled centrifugal clutches"
      ],
      "description": "Magnet driver command to each clutch; engagement state feedback",
      "defined": false
    },
    {
      "id": "I-09",
      "kind": "electrical",
      "between": [
        "Permanent-magnet generators 1.5 kW",
        "Rectifiers, DC bus and listed hybrid inverter"
      ],
      "description": "Generator AC to rectifiers / DC bus",
      "defined": false
    },
    {
      "id": "I-10",
      "kind": "signal",
      "between": [
        "Spring-applied fail-safe brake",
        "Supervisory controller"
      ],
      "description": "Brake release / apply and overspeed trip",
      "defined": false
    }
  ],
  "power_budget": [
    {
      "source": "CALC-01 Rotor shaft power",
      "value": 3.8102,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 Rotor shaft power",
      "value": 0.47628,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-04 Electrical output (staged)",
      "value": 3.2712,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-05 Electrical output (staged)",
      "value": 0.35719,
      "unit": "kW",
      "basis": "calculated from assumptions"
    }
  ],
  "environment": [
    "Outdoor, rural/suburban site, −20 to +45 °C, corrosivity C3, IEC small-wind class III (assumed).",
    "REQ-ENV-001: −20 to +45 °C; ISO 12944 C3; enclosures IP54 min",
    "REQ-ENV-002: ≤ local limit (typ. 45 dB(A) at night)"
  ],
  "safety": [
    "REQ-SAFE-001: Survive the 50-year extreme wind parked without structural failure. (Ve50 = 52.5 m/s (IEC 61400-2 class III))",
    "REQ-SAFE-002: A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid. (stop from 1.3× rated speed; PL c or better (ISO 13849))",
    "REQ-SAFE-003: All rotating parts accessible at ground level shall be guarded. (ISO 12100 / ISO 13857 distances)",
    "REQ-STR-001: The foundation shall resist overturning and sliding and stay within allowable soil bearing. (FS ≥ 1.5 overturning and sliding; q ≤ q_allow)"
  ],
  "standards": [
    {
      "id": "IEC 60204-1",
      "title": "Safety of machinery — Electrical equipment of machines"
    },
    {
      "id": "IEC 61000 series",
      "title": "Electromagnetic compatibility"
    },
    {
      "id": "ISO 13849-1/-2",
      "title": "Safety of machinery — Safety-related parts of control systems"
    },
    {
      "id": "IEC 60529",
      "title": "Degrees of protection provided by enclosures (IP code)"
    }
  ],
  "requirements": [
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the 50-year extreme wind parked without structural failure.",
      "target": "Ve50 = 52.5 m/s (IEC 61400-2 class III)"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid.",
      "target": "stop from 1.3× rated speed; PL c or better (ISO 13849)"
    },
    {
      "code": "REQ-SAFE-003",
      "text": "All rotating parts accessible at ground level shall be guarded.",
      "target": "ISO 12100 / ISO 13857 distances"
    },
    {
      "code": "REQ-INT-001",
      "text": "The vertical shaft shall run clear of its bending critical speeds.",
      "target": "critical / max running speed ≥ 1.25"
    },
    {
      "code": "REQ-STR-001",
      "text": "The foundation shall resist overturning and sliding and stay within allowable soil bearing.",
      "target": "FS ≥ 1.5 overturning and sliding; q ≤ q_allow"
    },
    {
      "code": "REQ-REG-001",
      "text": "Follow a recognised small-wind certification path.",
      "target": "IEC 61400-2 or ANSI/ACP 101-1"
    },
    {
      "code": "REQ-REG-002",
      "text": "Grid-connected operation shall use listed interconnection equipment.",
      "target": "UL 1741 / IEEE 1547"
    }
  ],
  "open_questions": [
    "G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?"
  ]
}

Discipline scopes

Aerodynamics and fluids 2 items
Items
1.1 Rotor; 1.1.1 Blades (H-rotor, pultruded aerofoil)
Inputs
CALC-01 Rotor power, speed and torque at rated wind: Swept area 12 m², Power in the wind (Cp = 1) 12.701 kW, Rotor shaft power 3.8102 kW, Rotor speed 229.18 rpm
CALC-02 Rotor power at the site mean wind (part load): Swept area 12 m², Power in the wind (Cp = 1) 1.5876 kW, Rotor shaft power 0.47628 kW, Rotor speed 114.59 rpm
CALC-03 Annual energy production at the site: Weibull scale c 6.7703 m/s, Rated rotor power 3.8102 kW, Mean electrical power 0.66612 kW, Annual energy production 5835.2 kWh
Standards
IEC 61400-2, IEC 61400-12-1
Deliverables
Blade static test to 1.35 × extreme load; mass and balance within tolerance
Open
G-02: Is the rotor a vertical-axis rotor on top of the tower, or a horizontal-axis rotor with a right-angle gear into the vertical shaft?; G-03: Where will the prototype stand? Site wind data (or a nearby met station) and the permitting authority.
Structural 8 items
Items
1.1.2 Blade struts / arms; 1.3.4 Steady-bearing brackets in tower; 1.8 Tower; 1.8.1 Tubular steel tower, flanged sections; 1.8.2 Tower base flange bolts (M24, class 10.9); 1.8.3 Tower base plate; 1.8.4 Service access: hatch, climbing / tower-lowering provision; 1.9.3 Anchor rods (M30, F1554 Gr 55) and setting template
Inputs
CALC-10 Parked extreme wind on rotor and tower: Velocity pressure 1688.2 Pa, Rotor force 24.31 kN, Tower force 6.4827 kN, Total base shear 30.793 kN
CALC-14 Tower base flange bolts under parked extreme wind: Tensile stress area As 352.5 mm², Proof load per bolt 292.58 kN, Preload per bolt 204.8 kN, Tightening torque 983.06 N·m
CALC-16 Anchor rods: steel strength under factored extreme wind: Peak anchor tension 110.97 kN, Shear per anchor 2.5661 kN, Design tensile strength φNsa 217.37 kN, Design shear strength φVsa 113.03 kN
Standards
ANSI/AISC 360, AWS D1.1, ASCE/SEI 7, ISO 898-1, VDI 2230 Part 1, 29 CFR 1910 / 1926, ASTM F1554, ACI 318
Deliverables
Fatigue check at 2P cyclic load; joint test; Bracket stiffness ≥ 10 × bearing radial stiffness requirement; Member and connection checks by structural engineer; tower frequency clear of 1P/2P/3P; Preload verified; fatigue check; Plate bending and weld checks (AISC DG1); Top bearing reachable with fall protection, or tower tilts down; Steel and concrete-breakout strength checked (ACI 318 ch. 17)
Mechanical / machine design 17 items
Items
1.1.3 Rotor hub; 1.1.4 Blade and strut fasteners; 1.2 Top bearing and rotor support; 1.2.1 Top radial bearing (spherical roller); 1.2.2 Thrust bearing carrying rotor and shaft weight; 1.2.3 Bearing housing, seals and lubrication; 1.3 Vertical transmission shaft; 1.3.1 Shaft segments; 1.3.2 Segment couplings (disc type); 1.3.3 Intermediate steady bearings; 1.4 Ground-level gear stage; 1.4.1 Speed-up gearbox (planetary or helical); 1.4.2 Power take-off to generator branches; 1.4.3 Gearbox lubricant; 1.5.1 Magnetically controlled centrifugal clutches; 1.5.3 Generator couplings (jaw); 1.6.1 Spring-applied fail-safe brake
Inputs
CALC-07 Vertical shaft fatigue at rated torque with 2P ripple: von Mises alternating stress σa' 6.8398 MPa, von Mises mean stress σm' 9.7254 MPa, Corrected endurance limit Se 227.62 MPa, Surface factor ka 0.72992
CALC-08 Shaft critical speed with two steady bearings (3 spans): First critical speed 663.4 rpm, Critical / running speed 2.2267 , Longest span keeping the margin 4.4044 m
CALC-09 Rejected option: one 10 m span with no steady bearings: First critical speed 72.244 rpm, Critical / running speed 0.24248 , Longest span keeping the margin 4.4044 m
CALC-11 Top bearing life (weight + operating radial load) and static safety at extreme wind: Equivalent dynamic load P 14.238 kN, Basic rating life L10 6687.3 Mrev, Basic rating life L10h 486320 h, Life at 90 % reliability 486320 h
CALC-12 Speed-up stage pinion bending (screening): Pitch diameter 54 mm, Tangential load Wt 1356.9 N, Pitch-line velocity 4.2119 m/s, Velocity factor Kv 1.6905
CALC-13 Clutch engagement onto a stationary generator: Torque needed 3.12 N·m, Slip heat per engagement 0.36503 kJ, Plate temperature rise per engagement 0.79354 K, Average slip heat in the worst hour 3.0419 W
Standards
AWS D1.1, ISO 898-1, VDI 2230 Part 1, ISO 281, ISO 76, ISO 286-1/-2, DIN 743, ISO 21940-11, ANSI/AGMA 2001-D04, ISO 6336-1/-2/-3, ANSI/AGMA/AWEA 6006, ISO 13849-1/-2
Deliverables
Weld inspection; bolt pattern to drawing; Torque-tension verified; locking method for vibration; L10 ≥ 100 000 h; s0 ≥ 2 at extreme load; L10 ≥ 100 000 h under weight + vertical aero load; IP55 seal; relubrication access from the tower top platform; Fatigue reserve ≥ target; straightness ≤ 0.1 mm/m; balance G6.3; Rated torque ≥ 2 × rated shaft torque; misalignment within rating; Spacing keeps critical-speed separation ≥ 1.25; Rated ≥ 1.5 × rated torque (service factor); efficiency ≥ 96 %; All branches driven at equal speed; branch disconnect possible for service; Viscosity grade suits −20 °C start; Engages and releases at set thresholds with hysteresis; slip heat within plate rating at 30 engagements/h; Torque rating ≥ 2 × generator rated torque; Stops rotor from 1.3 × rated speed; holds at Ve50 parked torque
Open
G-05: How does the magnet control the centrifugal clutch (hold shoes retracted, add engagement force, or release a latch)? Are thresholds set by speed or by power?
Electrical power 7 items
Items
1.5 Staged generator bank; 1.5.2 Permanent-magnet generators 1.5 kW; 1.7 Power electronics, controls and electrical; 1.7.2 Rectifiers, DC bus and listed hybrid inverter; 1.7.3 Dump load / diversion resistor; 1.7.5 Enclosures, disconnects, wiring and earthing; 1.9.5 Earthing electrode and lightning protection
Inputs
CALC-04 Staged generator bank at rated power: Power at generator shaft 3.6178 kW, Generators engaged 3 , Load on each engaged generator 80.395 %, Electrical output (staged) 3.2712 kW
CALC-05 Staged generator bank at part load: staged vs one generator: Power at generator shaft 0.41723 kW, Generators engaged 1 , Load on each engaged generator 27.815 %, Electrical output (staged) 0.35719 kW
CALC-06 Energy balance at rated: no output beyond input: Implied efficiency 85.854 %, Unaccounted losses 0.00004 kW
CALC-13 Clutch engagement onto a stationary generator: Torque needed 3.12 N·m, Slip heat per engagement 0.36503 kJ, Plate temperature rise per engagement 0.79354 K, Average slip heat in the worst hour 3.0419 W
Standards
IEC 60034-1/-2-1, UL 1741, IEEE 1547, NFPA 70 (NEC) Art. 690, 694, 705, IEC 60204-1, IEC 60529
Deliverables
Measured efficiency map from 10–100 % load; Listed equipment; MPPT tuned to the staged bank; Absorbs rated power continuously on loss of grid; IP54+; NEC 694 disconnects; bonding verified; Earth resistance ≤ 25 Ω (or as specified)
Open
G-06: Which generators: maker, rated speed, efficiency map, inertia?; G-07: Grid-tied, battery-based or both?
Controls and software 3 items
Items
1.6 Braking and overspeed protection; 1.6.2 Redundant overspeed sensing; 1.7.4 Sensors: anemometer, shaft speed/torque, vibration, temperatures
Standards
ISO 13849-1/-2, ISO 12100, ISO 20816-1/-21
Deliverables
Two independent channels; trip verified by test; Instrumentation list complete for prototype test plan
Civil and geotechnical 4 items
Items
1.9 Foundation; 1.9.1 Reinforced-concrete spread footing; 1.9.2 Reinforcement; 1.9.4 Base-plate grout
Inputs
CALC-15 Spread footing: overturning, sliding, soil bearing: Footing weight 231.28 kN, Soil cover weight 110.25 kN, Total stabilising vertical load 356.53 kN, Overturning moment at base 309.06 kN·m
CALC-16 Anchor rods: steel strength under factored extreme wind: Peak anchor tension 110.97 kN, Shear per anchor 2.5661 kN, Design tensile strength φNsa 217.37 kN, Design shear strength φVsa 113.03 kN
Standards
ACI 318, ASCE/SEI 7, International Building Code (as adopted locally), ASTM A615 / A706
Deliverables
FS ≥ 1.5 overturning/sliding; bearing ≤ allowable from the geotechnical report; Flexure and punching shear by structural engineer; Full bearing under base plate
Open
G-04: Geotechnical report: allowable bearing, friction, frost depth, water table.
Manufacturing 4 items
Items
1.10 Generator house, guards and service provisions; 1.10.1 Weatherproof generator house; 1.10.2 Guards on rotating parts; 1.10.3 Lifting points and generator slide rails
Standards
ISO 12100, IEC 60529
Deliverables
IP54; ventilation keeps generators within rating at 45 °C; Interlocked access; ISO 13857 distances; Generator swap demonstrated in ≤ 4 h

Exports

Every export is marked preliminary. Nothing here claims certification or construction readiness.