Reference projects / Vertical-transmission wind turbineConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Calculations
Deterministic, unit-aware methods (never language-model arithmetic). Each run records its method version, the exact inputs and a fingerprint. Inputs read the design basis ($name) and earlier results (@CALC-xx.output), so changing a value re-runs exactly what depends on it.
Design basis 46 values · 37 assumed
Preliminary reserve target 20 % — capacity/demand ≥ 1.20; mandatory code factors govern (spec §06).
CALC-01 Rotor power, speed and torque at rated wind
Wind rotor power, speed and torque · v1.0.0 · item 1.1 · REQ-PERF-001pass
Results
| Swept area | 12 m² |
| Power in the wind (Cp = 1) | 12.7 kW |
| Rotor shaft power | 3.81 kW |
| Rotor speed | 229.2 rpm |
| Rotor shaft torque | 158.8 N·m |
Inputs used
| Rotor type | vawt | |
| Rotor diameter | 3 m | $rotor_diameter |
| Rotor height (vertical axis) | 4 m | $rotor_height |
| Air density | 1.225 kg/m³ | $rho |
| Wind speed at the rotor | 12 m/s | $v_rated |
| Power coefficient Cp | 0.3 | $cp |
| Tip-speed ratio λ | 3 | $tsr |
Fingerprint 1e2a31c81edddf · rests on assumed: rotor_diameter, rotor_height, v_rated, tsr · method record
CALC-02 Rotor power at the site mean wind (part load)
Wind rotor power, speed and torque · v1.0.0 · item 1.1 · REQ-PERF-003pass
Results
| Swept area | 12 m² |
| Power in the wind (Cp = 1) | 1.588 kW |
| Rotor shaft power | 0.4763 kW |
| Rotor speed | 114.6 rpm |
| Rotor shaft torque | 39.69 N·m |
Inputs used
| Rotor type | vawt | |
| Rotor diameter | 3 m | $rotor_diameter |
| Rotor height (vertical axis) | 4 m | $rotor_height |
| Air density | 1.225 kg/m³ | $rho |
| Wind speed at the rotor | 6 m/s | $mean_wind |
| Power coefficient Cp | 0.3 | $cp |
| Tip-speed ratio λ | 3 | $tsr |
Fingerprint 163126148f95dd · rests on assumed: rotor_diameter, rotor_height, mean_wind, tsr · method record
CALC-03 Annual energy production at the site
Annual energy production (Weibull site) · v1.0.0 · item 1.1 · REQ-PERF-004pass
Results
| Weibull scale c | 6.77 m/s |
| Rated rotor power | 3.81 kW |
| Mean electrical power | 0.6661 kW |
| Annual energy production | 5,835 kWh |
| Capacity factor (of rated electrical) | 20.23 % |
| Hours between cut-in and cut-out | 6,706 h |
Inputs used
| Swept area | 12 m² | @CALC-01.area |
| Air density | 1.225 kg/m³ | $rho |
| Power coefficient Cp | 0.3 | $cp |
| Annual mean wind speed | 6 m/s | $mean_wind |
| Weibull shape k | 2 | $weibull_k |
| Cut-in speed | 3.5 m/s | $v_cut_in |
| Rated speed | 12 m/s | $v_rated |
| Cut-out speed | 25 m/s | $v_cut_out |
| Drivetrain + generator + converter efficiency | 0.864 | $eta_gear*$eta_gen |
| Availability | 0.95 |
Fingerprint 1c17bf6170d6b7 · rests on assumed: mean_wind, weibull_k, v_cut_in, v_rated, v_cut_out, eta_gen · method record
CALC-04 Staged generator bank at rated power
Staged multi-generator drivetrain: energy balance · v1.0.0 · item 1.5 · REQ-PERF-001pass
Results
| Power at generator shaft | 3.618 kW |
| Generators engaged | 3 |
| Load on each engaged generator | 80.39 % |
| Electrical output (staged) | 3.271 kW |
| Electrical output (one generator of the same total rating) | 3.271 kW |
| Gain from staging at this point | 0 kW |
| Gear loss | 0.1524 kW |
| Bearing + seal loss | 0.04 kW |
| Generator losses | 0.3466 kW |
| Power shed (above installed rating) | 0 kW |
| Rotor-to-electrical efficiency | 85.86 % |
| Generator speed | 1,490 rpm |
| Torque on each generator shaft | 7.73 N·m |
| Energy balance residual | 0 kW |
Inputs used
| Rotor shaft power | 3.81 kW | @CALC-01.p_rotor |
| Rotor speed | 229.2 rpm | @CALC-01.rpm |
| Gear ratio (speed-up) | 6.5 | $gear_ratio |
| Gear stage efficiency | 0.96 | $eta_gear |
| Bearing + seal losses (total) | 0.04 kW | $bearing_loss |
| Number of generators | 3 | $n_gen |
| Rating of each generator | 1.5 kW | $p_gen |
| Generator efficiency at rated load | 0.9 | $eta_gen |
| Share of rated loss that is fixed | 0.35 | $gen_fixed_share |
| Engage the next generator at this load fraction | 0.8 |
Fingerprint 1c7b225deb0d7e · rests on assumed: gear_ratio, bearing_loss, n_gen, p_gen, eta_gen, gen_fixed_share · method record
CALC-05 Staged generator bank at part load: staged vs one generator
Staged multi-generator drivetrain: energy balance · v1.0.0 · item 1.5 · REQ-PERF-003pass
Results
| Power at generator shaft | 0.4172 kW |
| Generators engaged | 1 |
| Load on each engaged generator | 27.82 % |
| Electrical output (staged) | 0.3572 kW |
| Electrical output (one generator of the same total rating) | 0.2572 kW |
| Gain from staging at this point | 0.09997 kW |
| Gear loss | 0.01905 kW |
| Bearing + seal loss | 0.04 kW |
| Generator losses | 0.06004 kW |
| Power shed (above installed rating) | 0 kW |
| Rotor-to-electrical efficiency | 75 % |
| Generator speed | 744.8 rpm |
| Torque on each generator shaft | 5.349 N·m |
| Energy balance residual | 0 kW |
Inputs used
| Rotor shaft power | 0.4763 kW | @CALC-02.p_rotor |
| Rotor speed | 114.6 rpm | @CALC-02.rpm |
| Gear ratio (speed-up) | 6.5 | $gear_ratio |
| Gear stage efficiency | 0.96 | $eta_gear |
| Bearing + seal losses (total) | 0.04 kW | $bearing_loss |
| Number of generators | 3 | $n_gen |
| Rating of each generator | 1.5 kW | $p_gen |
| Generator efficiency at rated load | 0.9 | $eta_gen |
| Share of rated loss that is fixed | 0.35 | $gen_fixed_share |
| Engage the next generator at this load fraction | 0.8 |
Fingerprint 0c625420a0c46d · rests on assumed: gear_ratio, bearing_loss, n_gen, p_gen, eta_gen, gen_fixed_share · method record
CALC-06 Energy balance at rated: no output beyond input
Energy balance check · v1.0.0 · item 1.5 · REQ-PERF-001pass
Results
| Implied efficiency | 85.85 % |
| Unaccounted losses | 4.00e-5 kW |
Inputs used
| Total power in | 3.81 kW | @CALC-01.p_rotor |
| Claimed useful power out | 3.271 kW | @CALC-04.p_elec |
| Known losses | 0.539 kW | @CALC-04.loss_gear+@CALC-04.loss_bearing+@CALC-04.loss_gen |
Checks (capacity / demand)
| output within input less known losses | 3.271 / 3.271 kW | 1 ≥ 1 | pass | conservation of energy |
Fingerprint 0384e89359244b · method record
CALC-07 Vertical shaft fatigue at rated torque with 2P ripple
Shaft fatigue and yield (DE-Goodman) · v1.0.0 · item 1.3.1 · REQ-LIFE-001pass
Results
| von Mises alternating stress σa' | 6.84 MPa |
| von Mises mean stress σm' | 9.725 MPa |
| Corrected endurance limit Se | 227.6 MPa |
| Surface factor ka | 0.7299 |
| Size factor kb | 0.794 |
| Fatigue factor of safety (DE-Goodman) | 24.92 |
| Yield factor of safety (first cycle) | 42.64 |
Inputs used
| Shaft diameter at the section | 60 mm | $shaft_d |
| Bore (0 for solid) | 0 mm | |
| Alternating bending moment | 60 N·m | $shaft_bending |
| Mean bending moment | 0 N·m | |
| Alternating torque | 79.38 N·m | @CALC-01.torque*$torque_ripple |
| Mean torque | 158.8 N·m | @CALC-01.torque |
| Fatigue stress-concentration factor Kf (bending) | 1.7 | |
| Fatigue stress-concentration factor Kfs (torsion) | 1.5 | |
| Ultimate tensile strength | 965 MPa | $shaft_sut |
| Yield strength | 655 MPa | $shaft_sy |
| Surface finish | machined | |
| Reliability | 99 | |
| Temperature factor kd | 1 |
Checks (capacity / demand)
| fatigue (DE-Goodman) | 24.92 / 1 factor | 24.9 ≥ 1.2 | pass | project reserve 20 %; machine-design practice is often 1.5–2.0 — reviewer sets the governing value | |
| first-cycle yield | 42.64 / 1 factor | 42.6 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) |
Fingerprint 06eb4d91ece8b7 · rests on assumed: shaft_d, shaft_bending, torque_ripple · method record
CALC-08 Shaft critical speed with two steady bearings (3 spans)
Shaft first critical speed (uniform, simply supported span) · v1.0.0 · item 1.3.3 · REQ-INT-001pass
Results
| First critical speed | 663.4 rpm |
| Critical / running speed | 2.227 |
| Longest span keeping the margin | 4.404 m |
Inputs used
| Span between bearings | 3.3 m | $shaft_span_supported |
| Outside diameter | 60 mm | $shaft_d |
| Bore (0 for solid) | 0 mm | |
| Elastic modulus | 205 GPa | |
| Density | 7,850 kg/m³ | |
| Maximum running speed | 297.9 rpm | @CALC-01.rpm*$overspeed |
| Required separation (critical / running) | 1.25 |
Checks (capacity / demand)
| critical-speed separation | 663.4 / 297.9 rpm | 2.23 ≥ 1.25 | pass | separation ≥ 1.25 (common practice; confirm with a rotordynamic analysis) |
Fingerprint 072ed34a50b175 · rests on assumed: shaft_span_supported, shaft_d, overspeed · method record
CALC-09 Rejected option: one 10 m span with no steady bearingsrejected alternative — not counted
Shaft first critical speed (uniform, simply supported span) · v1.0.0 · item 1.3 · REQ-INT-001fail
Results
| First critical speed | 72.24 rpm |
| Critical / running speed | 0.2425 |
| Longest span keeping the margin | 4.404 m |
Inputs used
| Span between bearings | 10 m | $shaft_span_unsupported |
| Outside diameter | 60 mm | $shaft_d |
| Bore (0 for solid) | 0 mm | |
| Elastic modulus | 205 GPa | |
| Density | 7,850 kg/m³ | |
| Maximum running speed | 297.9 rpm | @CALC-01.rpm*$overspeed |
| Required separation (critical / running) | 1.25 |
Checks (capacity / demand)
| critical-speed separation | 72.24 / 297.9 rpm | 0.242 ≥ 1.25 | FAIL | separation ≥ 1.25 (common practice; confirm with a rotordynamic analysis) |
Fingerprint 185a19354b59a3 · rests on assumed: shaft_span_unsupported, shaft_d, overspeed · method record
CALC-10 Parked extreme wind on rotor and tower
Rotor and tower wind thrust, base reactions · v1.0.0 · item 1.8 · REQ-SAFE-001warn
Results
| Velocity pressure | 1,688 Pa |
| Rotor force | 24.31 kN |
| Tower force | 6.483 kN |
| Total base shear | 30.79 kN |
| Overturning moment at base | 269 kN·m |
Inputs used
| Design wind speed | 52.5 m/s | $v_extreme |
| Air density | 1.225 kg/m³ | $rho |
| Rotor projected area | 12 m² | @CALC-01.area |
| Rotor thrust / drag coefficient | 1.2 | $ct_parked |
| Height of rotor centre above base | 10 m | $rotor_center_height |
| Tower width / diameter | 0.4 m | $tower_diameter |
| Tower height | 8 m | $tower_height |
| Tower drag coefficient | 1.2 |
- Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer
Fingerprint 0ac614b0714992 · rests on assumed: ct_parked, rotor_center_height, tower_diameter, tower_height · method record
CALC-11 Top bearing life (weight + operating radial load) and static safety at extreme wind
Rolling bearing rating life (ISO 281 basic) and static safety · v1.0.0 · item 1.2.1 · REQ-LIFE-002warn
Results
| Equivalent dynamic load P | 14.24 kN |
| Basic rating life L10 | 6,687 Mrev |
| Basic rating life L10h | 486,300 h |
| Life at 90 % reliability | 486,300 h |
| Static safety factor s0 | 8.885 |
Inputs used
| Bearing type | roller | |
| Basic dynamic load rating C | 200 kN | $top_bearing_c |
| Basic static load rating C0 | 216 kN | $top_bearing_c0 |
| Radial load Fr | 0.9526 kN | 0.5*$rho*$v_rated*$v_rated*@CALC-01.area*0.9/1000 |
| Axial load Fa | 4 kN | $rotating_weight |
| Radial factor X | 0.67 | |
| Axial factor Y | 3.4 | |
| Equivalent static load P0 (peak) | 24.31 kN | @CALC-10.f_rotor |
| Speed | 229.2 rpm | @CALC-01.rpm |
| Reliability | 90 | |
| Required life | 100,000 h | |
| Required static safety s0 | 2 |
Checks (capacity / demand)
| rating life | 486,300 / 100,000 h | 4.86 ≥ 1 | pass | required life (the reserve is in the life requirement) | |
| static safety | 8.885 / 2 | 4.44 ≥ 1 | pass | s0 ≥ 2 (ISO 76 / maker guidance) |
- Basic life only: run the maker's calculator (a_ISO, lubrication, contamination) before selection
Fingerprint 08d3b1dec65337 · rests on assumed: v_rated, rotating_weight · method record
CALC-12 Speed-up stage pinion bending (screening)
Spur gear tooth bending (Lewis screening) · v1.0.0 · item 1.4.1 · REQ-LIFE-001warn
Results
| Pitch diameter | 54 mm |
| Tangential load Wt | 1,357 N |
| Pitch-line velocity | 4.212 m/s |
| Velocity factor Kv | 1.69 |
| Lewis form factor Y | 0.309 |
| Bending stress | 82.48 MPa |
Inputs used
| Module m | 3 mm | |
| Teeth on the pinion | 18 | |
| Face width F | 30 mm | |
| Pinion torque | 36.64 N·m | @CALC-01.torque/$gear_ratio*1.5 |
| Pinion speed | 1,490 rpm | @CALC-01.rpm*$gear_ratio |
| Allowable bending stress | 250 MPa |
Checks (capacity / demand)
| tooth bending | 250 / 82.48 MPa | 3.03 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) |
- Lewis screening only: rate to AGMA 2001 / ISO 6336 (bending and contact) before selection
Fingerprint 0eea5a839c3f3e · rests on assumed: gear_ratio · method record
CALC-13 Clutch engagement onto a stationary generator
Clutch engagement: torque, slip energy and temperature rise · v1.0.0 · item 1.5.1 · REQ-PERF-003pass
Results
| Torque needed | 3.12 N·m |
| Slip heat per engagement | 0.365 kJ |
| Plate temperature rise per engagement | 0.7935 K |
| Average slip heat in the worst hour | 3.042 W |
Inputs used
| Generator + coupling inertia (on clutch shaft) | 0.03 kg·m² | $gen_inertia |
| Shaft speed at engagement | 1,490 rpm | @CALC-01.rpm*$gear_ratio |
| Engagement time | 1.5 s | |
| Load torque during engagement | 0 N·m | |
| Clutch torque capacity | 30 N·m | $clutch_capacity |
| Clutch friction plate mass | 1 kg | |
| Plate specific heat | 460 J/(kg·K) | |
| Engagements per hour (worst gusty hour) | 30 |
Checks (capacity / demand)
| clutch torque capacity | 30 / 3.12 N·m | 9.62 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) |
Fingerprint 12614dbc29779b · rests on assumed: gen_inertia, gear_ratio, clutch_capacity · method record
CALC-14 Tower base flange bolts under parked extreme wind
Bolted joint: preload, tightening torque, separation and slip · v1.0.0 · item 1.8.2 · REQ-SAFE-001pass
Results
| Tensile stress area As | 352.5 mm² |
| Proof load per bolt | 292.6 kN |
| Preload per bolt | 204.8 kN |
| Tightening torque | 983.1 N·m |
| Load factor n_L | 3.132 |
| Separation factor n_0 | 2.436 |
| Slip factor | 18.82 |
Inputs used
| Thread size | M24 | |
| Property class | 10.9 | |
| Number of bolts | 16 | |
| External tension on the group | 1,794 kN | 4*@CALC-10.m_base/$flange_bcd |
| Shear on the group | 30.79 kN | @CALC-10.h_total |
| Preload as fraction of proof load | 0.7 | |
| Joint stiffness fraction C | 0.25 | |
| Nut factor K | 0.2 | |
| Friction coefficient of the faying surfaces | 0.3 |
Checks (capacity / demand)
| bolt load within proof (load factor) | 87.77 / 28.02 kN | 3.13 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) | |
| joint separation | 204.8 / 84.07 kN | 2.44 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) | |
| slip (friction grip) | 579.5 / 30.79 kN | 18.8 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) |
Fingerprint 070e2299f8f6d6 · rests on assumed: flange_bcd · method record
CALC-15 Spread footing: overturning, sliding, soil bearing
Square spread footing: overturning, sliding and soil bearing · v1.0.0 · item 1.9.1 · REQ-STR-001warn
Results
| Footing weight | 231.3 kN |
| Soil cover weight | 110.3 kN |
| Total stabilising vertical load | 356.5 kN |
| Overturning moment at base | 309.1 kN·m |
| Eccentricity | 0.8669 m |
| Peak soil pressure | 76.9 kPa |
| Minimum soil pressure | 0 kPa |
| Concrete volume | 9.8 m³ |
Inputs used
| Footing width B (square) | 3.5 m | $footing_b |
| Footing thickness D | 0.8 m | $footing_d |
| Soil cover over footing h | 0.5 m | $soil_cover |
| Concrete unit weight | 23.6 kN/m³ | |
| Soil unit weight | 18 kN/m³ | |
| Vertical load from structure (dead) | 15 kN | $dead_load |
| Horizontal load at grade | 30.79 kN | @CALC-10.h_total |
| Moment at grade | 269 kN·m | @CALC-10.m_base |
| Allowable soil bearing pressure | 150 kPa | $q_allow |
| Base friction coefficient | 0.45 | $soil_mu |
| Required FS overturning | 1.5 | |
| Required FS sliding | 1.5 |
Checks (capacity / demand)
| overturning | 623.9 / 309.1 kN·m | 2.02 ≥ 1.5 | pass | FS ≥ 1.5 (common practice; code combinations govern) | |
| sliding | 160.4 / 30.79 kN | 5.21 ≥ 1.5 | pass | FS ≥ 1.5 (common practice; code combinations govern) | |
| soil bearing | 150 / 76.9 kPa | 1.95 ≥ 1 | pass | allowable bearing pressure from the geotechnical engineer (already includes its factor) |
- eccentricity 0.87 m exceeds B/6 = 0.58 m: part of the base lifts off the soil (allowed by some codes for wind, not for sustained loads)
- Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)
Fingerprint 1ab1c2b9aa99ab · rests on assumed: footing_b, footing_d, soil_cover, dead_load, q_allow, soil_mu · method record
CALC-16 Anchor rods: steel strength under factored extreme wind
Anchor bolts on a bolt circle: tension and shear (steel strength) · v1.0.0 · item 1.9.3 · REQ-STR-001warn
Results
| Peak anchor tension | 111 kN |
| Shear per anchor | 2.566 kN |
| Design tensile strength φNsa | 217.4 kN |
| Design shear strength φVsa | 113 kN |
| Tension–shear interaction | 0.5332 |
Inputs used
| Number of anchors | 12 | $anchor_n |
| Bolt-circle diameter | 0.8 m | $bolt_circle |
| Anchor size | M30 | |
| Anchor grade | F1554-55 | |
| Factored moment at base | 269 kN·m | @CALC-10.m_base*$wind_load_factor |
| Factored axial compression (dead, minimum) | 13.5 kN | 0.9*$dead_load |
| Factored base shear | 30.79 kN | @CALC-10.h_total*$wind_load_factor |
Checks (capacity / demand)
| anchor tension (steel) | 217.4 / 111 kN | 1.96 ≥ 1.2 | pass | LRFD φ factors applied; plus project reserve 20 % | |
| anchor shear (steel) | 113 / 2.566 kN | 44 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) | |
| tension–shear interaction (≤ 1.2) | 1.2 / 0.5332 | 2.25 ≥ 1 | pass | ACI 318 §17.8 interaction |
- Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)
Fingerprint 0ba6b42d89d526 · rests on assumed: anchor_n, bolt_circle, dead_load · method record