Reference projects / Vertical-transmission wind turbineConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Brief and requirements
Concept brief
- Function
- Generate electricity from wind with high part-load efficiency and ground-level maintenance of the drivetrain.
- Environment
- Outdoor, rural/suburban site, −20 to +45 °C, corrosivity C3, IEC small-wind class III (assumed).
- Scale
- Small wind: ≈ 12 m² swept area, ≈ 3–4 kW rated (prototype scale); architecture intended to scale.
- Budget
- Not yet stated (gap G-10).
- Constraints
- Generators, clutches and gearbox serviceable from the ground · No performance claim until supported by test · Conventional drivetrain and direct-drive are the baselines
Requirements and traceability
Requirement → parts → calculations / tests (spec §03). “Assumed” means the supporting calculation rests on values not yet confirmed.
| Code | Requirement | Target | Verified by | Allocated to | Evidence |
|---|---|---|---|---|---|
| REQ-PERF-001critical | Rated electrical output at 12 m/s hub wind speed. | ≥ 3.0 kW electrical at 12 m/s | test | 1, 1.1 | assumedCALC-01CALC-04CALC-06 |
| REQ-PERF-002 | Begin producing power at low wind speed. | cut-in ≤ 3.5 m/s | test | 1.1 | test planned |
| REQ-PERF-003critical | Staged generator engagement shall raise part-load conversion efficiency compared with one generator of the same total rating. | ≥ +5 % electrical output at 6 m/s | analysis | 1.5 | assumedCALC-02CALC-05CALC-13 |
| REQ-PERF-004critical | Annual energy production shall be reported against conventional geared and direct-drive baselines with the same rotor. | AEP at 6 m/s Rayleigh, with uncertainty | analysis | 1 | assumedCALC-03 |
| REQ-SAFE-001critical | Survive the 50-year extreme wind parked without structural failure. | Ve50 = 52.5 m/s (IEC 61400-2 class III) | analysis | 1.8 | assumedCALC-10CALC-14 |
| REQ-SAFE-002critical | A fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid. | stop from 1.3× rated speed; PL c or better (ISO 13849) | test | 1.6 | test planned |
| REQ-SAFE-003 | All rotating parts accessible at ground level shall be guarded. | ISO 12100 / ISO 13857 distances | inspection | 1.10 | test planned |
| REQ-INT-001critical | The vertical shaft shall run clear of its bending critical speeds. | critical / max running speed ≥ 1.25 | analysis | 1.3 | assumedCALC-08 |
| REQ-STR-001critical | The foundation shall resist overturning and sliding and stay within allowable soil bearing. | FS ≥ 1.5 overturning and sliding; q ≤ q_allow | analysis | 1.9 | assumedCALC-15CALC-16 |
| REQ-LIFE-001 | Design life. | 20 years | analysis | 1 | assumedCALC-07CALC-12 |
| REQ-LIFE-002 | Rolling bearings shall reach their rating life without replacement. | L10 ≥ 100 000 h | analysis | 1.2 | assumedCALC-11 |
| REQ-MAINT-001 | Generators, clutches, brake and gearbox shall be replaceable from ground level without climbing or a crane. | ≤ 4 h per generator swap, 2 people | demonstration | 1.10 | test planned |
| REQ-ENV-001 | Operating environment. | −20 to +45 °C; ISO 12944 C3; enclosures IP54 min | analysis | 1.10 | none |
| REQ-ENV-002 | Noise at the nearest dwelling. | ≤ local limit (typ. 45 dB(A) at night) | test | none | test planned |
| REQ-REG-001 | Follow a recognised small-wind certification path. | IEC 61400-2 or ANSI/ACP 101-1 | inspection | 1 | test planned |
| REQ-REG-002 | Grid-connected operation shall use listed interconnection equipment. | UL 1741 / IEEE 1547 | inspection | 1.7 | test planned |
| REQ-COST-001 | Prototype build cost and levelised cost of energy shall be estimated against the baselines. | costed range with exclusions | analysis | none | none |
Functions
- F1 Capture wind energy → 1.1 (start-up, power production, parked)
- F2 Carry rotor loads into the tower → 1.2 (all)
- F3 Transmit torque down to ground level → 1.3 (power production)
- F4 Raise speed for the generators → 1.4 (power production)
- F5 Engage generators in stages by available power → 1.5 (start-up, rising wind, falling wind)
- F6 Convert to electricity → 1.5 (power production)
- F7 Limit speed and stop safely → 1.6 (overspeed, loss of load, maintenance)
- F8 Condition and deliver power → 1.7 (grid-tied, battery)
- F9 Support and resist all loads → 1.8 (all)
- F10 Anchor to the ground → 1.9 (all)
- F11 Protect people and parts, allow service → 1.10 (all)