Brief and requirements

Concept brief

Function
Generate electricity from wind with high part-load efficiency and ground-level maintenance of the drivetrain.
Environment
Outdoor, rural/suburban site, −20 to +45 °C, corrosivity C3, IEC small-wind class III (assumed).
Scale
Small wind: ≈ 12 m² swept area, ≈ 3–4 kW rated (prototype scale); architecture intended to scale.
Budget
Not yet stated (gap G-10).
Constraints
Generators, clutches and gearbox serviceable from the ground · No performance claim until supported by test · Conventional drivetrain and direct-drive are the baselines

Requirements and traceability

Requirement → parts → calculations / tests (spec §03). “Assumed” means the supporting calculation rests on values not yet confirmed.

CodeRequirementTargetVerified byAllocated toEvidence
REQ-PERF-001criticalRated electrical output at 12 m/s hub wind speed.≥ 3.0 kW electrical at 12 m/stest1, 1.1assumedCALC-01CALC-04CALC-06
REQ-PERF-002Begin producing power at low wind speed.cut-in ≤ 3.5 m/stest1.1test planned
REQ-PERF-003criticalStaged generator engagement shall raise part-load conversion efficiency compared with one generator of the same total rating.≥ +5 % electrical output at 6 m/sanalysis1.5assumedCALC-02CALC-05CALC-13
REQ-PERF-004criticalAnnual energy production shall be reported against conventional geared and direct-drive baselines with the same rotor.AEP at 6 m/s Rayleigh, with uncertaintyanalysis1assumedCALC-03
REQ-SAFE-001criticalSurvive the 50-year extreme wind parked without structural failure.Ve50 = 52.5 m/s (IEC 61400-2 class III)analysis1.8assumedCALC-10CALC-14
REQ-SAFE-002criticalA fail-safe brake shall stop and hold the rotor on overspeed or loss of load/grid.stop from 1.3× rated speed; PL c or better (ISO 13849)test1.6test planned
REQ-SAFE-003All rotating parts accessible at ground level shall be guarded.ISO 12100 / ISO 13857 distancesinspection1.10test planned
REQ-INT-001criticalThe vertical shaft shall run clear of its bending critical speeds.critical / max running speed ≥ 1.25analysis1.3assumedCALC-08
REQ-STR-001criticalThe foundation shall resist overturning and sliding and stay within allowable soil bearing.FS ≥ 1.5 overturning and sliding; q ≤ q_allowanalysis1.9assumedCALC-15CALC-16
REQ-LIFE-001Design life.20 yearsanalysis1assumedCALC-07CALC-12
REQ-LIFE-002Rolling bearings shall reach their rating life without replacement.L10 ≥ 100 000 hanalysis1.2assumedCALC-11
REQ-MAINT-001Generators, clutches, brake and gearbox shall be replaceable from ground level without climbing or a crane.≤ 4 h per generator swap, 2 peopledemonstration1.10test planned
REQ-ENV-001Operating environment.−20 to +45 °C; ISO 12944 C3; enclosures IP54 minanalysis1.10none
REQ-ENV-002Noise at the nearest dwelling.≤ local limit (typ. 45 dB(A) at night)testnonetest planned
REQ-REG-001Follow a recognised small-wind certification path.IEC 61400-2 or ANSI/ACP 101-1inspection1test planned
REQ-REG-002Grid-connected operation shall use listed interconnection equipment.UL 1741 / IEEE 1547inspection1.7test planned
REQ-COST-001Prototype build cost and levelised cost of energy shall be estimated against the baselines.costed range with exclusionsanalysisnonenone