Reference projects / Solar HiveConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Feasibility
Classes (spec §06): supported preliminary feasibility · conditional feasibility · infeasible under stated assumptions · insufficient evidence. A design is never marked feasible because it meets cost or performance targets while a mandatory criterion fails, and independent specialist review is required before safety-critical use.
Critical requirements
| Requirement | Evidence | Status |
|---|---|---|
| REQ-PERF-001 Rated DC output of the prototype cluster. | CALC-01 (pass) | assumed |
| REQ-PERF-002 Annual energy shall be compared with a fixed-tilt array using the same modules. | CALC-01 (pass)CALC-02 (pass) | assumed |
| REQ-SAFE-001 Survive the design wind in stow position. | CALC-03 (warn) | assumed |
| REQ-SAFE-002 Stow automatically above a set wind speed and on loss of power. | test planned (S8 test plan) | test planned |
| REQ-STR-001 The mast foundation shall resist overturning and sliding within allowable soil bearing. | CALC-04 (warn)CALC-05 (warn) | assumed |
Results at a glance
| Calculation | Key results | Governing check | |
|---|---|---|---|
| CALC-01 Cluster output at peak sun, tracked annual energy | Cell temperature: 56.25 °C · Rated DC power at STC: 2.15 kW · DC output at this condition: 1.915 kW | — | pass |
| CALC-02 Same modules on a fixed-tilt baseline | Cell temperature: 56.25 °C · Rated DC power at STC: 2.15 kW · DC output at this condition: 1.915 kW | — | pass |
| CALC-03 Design wind on the stowed cluster and mast | Velocity pressure: 1,531 Pa · Rotor force: 7.166 kN · Tower force: 1.488 kN | — | warn |
| CALC-04 Mast pad: overturning, sliding, bearing | Footing weight: 66.08 kN · Soil cover weight: 28.8 kN · Total stabilising vertical load: 102.9 kN | overturning 3.09 vs 1.5 | warn |
| CALC-05 Mast anchor rods (steel strength) | Peak anchor tension: 25.47 kN · Shear per anchor: 1.082 kN · Design tensile strength φNsa: 94.92 kN | anchor tension (steel) 3.73 vs 1.2 | warn |
What would change the verdict
- A-01 (high sensitivity): PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast. see what it affects
- A-02 (high sensitivity): Active cell area 10 m² at 21.5 % module efficiency. see what it affects
- A-03 (high sensitivity): Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0. see what it affects
- A-05 (high sensitivity): Allowable soil bearing 150 kPa, friction 0.45. see what it affects
- G-01 (blocking): Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?
- G-02 (blocking): Custom hexagonal laminates, or standard certified modules in hexagonal frames?