VX Inventor · preliminary feasibility package · 2026-11-25
Solar Hive
Modular hexagonal solar cells clustered on a tracking mast (placeholder reading — import the invention's description).
1. Executive concept brief
A cluster of hexagonal PV 'cells' — modules in hexagonal frames — mounted around a central mast on a dual-axis tracking head, so modules can be added like cells of a hive and the whole cluster follows the sun. This is a placeholder architecture: it exists to exercise the solar standards, structural and energy methods until the Solar Hive's own documents are imported.
- Function
- Generate electricity from sunlight with a modular, expandable cluster that tracks the sun.
- Environment
- Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code.
- Scale
- Prototype: 7 hexagonal cells, ≈ 10 m² active area (assumed).
- Budget
- Not yet stated.
2. Feasibility
Conditional feasibility. All 5 mandatory calculations pass on the stated assumptions.
- G-01: Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?
- G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?
- A-01 must be confirmed: PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast.
- A-02 must be confirmed: Active cell area 10 m² at 21.5 % module efficiency.
- A-03 must be confirmed: Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0.
- A-05 must be confirmed: Allowable soil bearing 150 kPa, friction 0.45.
- CALC-03: Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer
- CALC-04: Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)
- CALC-05: Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)
3. Requirements
| REQ-PERF-001 | Rated DC output of the prototype cluster. | ≥ 2 kW DC at STC | assumed |
| REQ-PERF-002 | Annual energy shall be compared with a fixed-tilt array using the same modules. | kWh/kWp with uncertainty | assumed |
| REQ-SAFE-001 | Survive the design wind in stow position. | ASCE 7 basic wind speed for the site (assumed 50 m/s) | assumed |
| REQ-SAFE-002 | Stow automatically above a set wind speed and on loss of power. | stow ≤ 90 s from trigger | test planned |
| REQ-STR-001 | The mast foundation shall resist overturning and sliding within allowable soil bearing. | FS ≥ 1.5; q ≤ q_allow | assumed |
| REQ-MOD-001 | Cells shall be added or replaced without disturbing neighbouring cells. | one cell swap ≤ 30 min | test planned |
| REQ-REG-001 | Modules, racking and inverter listed for the jurisdiction. | IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690 | test planned |
| REQ-LIFE-001 | Design life. | 25 years (modules), 20 years (tracker drives) | none |
4. Product structure
| 1 | Solar Hive cluster (placeholder architecture) | Systems engineering | tbd |
| 1.1 | Hexagonal PV cells | Electrical power | tbd |
| 1.1.1 | PV laminates cut / built to hexagonal format ×7 | Electrical power | tbd |
| 1.1.2 | Hexagonal cell frames ×7 | Structural | make |
| 1.1.3 | Cell-to-hub quick connectors ×7 | Mechanical / machine design | make |
| 1.1.4 | DC wiring, connectors and bonding | Electrical power | buy |
| 1.2 | Tracking head | Mechanical / machine design | tbd |
| 1.2.1 | Azimuth slew drive | Mechanical / machine design | buy |
| 1.2.2 | Elevation actuator | Mechanical / machine design | buy |
| 1.2.3 | Hub slewing bearing | Mechanical / machine design | buy |
| 1.2.4 | Tracker controller with wind-stow | Electronics / PCB (VX Design) | make |
| 1.3 | Mast | Structural | tbd |
| 1.3.1 | Steel mast tube | Structural | make |
| 1.3.2 | Mast base plate and flange bolts | Structural | make |
| 1.4 | Foundation | Civil and geotechnical | tbd |
| 1.4.1 | Reinforced-concrete pad | Civil and geotechnical | make |
| 1.4.2 | Anchor rods ×8 | Structural | buy |
| 1.5 | Power conversion and interconnection | Electrical power | tbd |
| 1.5.1 | Microinverters or string inverter with MLPE | Electrical power | buy |
5. Engineering calculations
| CALC-01 | Cluster output at peak sun, tracked annual energy | Cell temperature 56.25 °C; Rated DC power at STC 2.15 kW; DC output at this condition 1.915 kW | pass |
| CALC-02 | Same modules on a fixed-tilt baseline | Cell temperature 56.25 °C; Rated DC power at STC 2.15 kW; DC output at this condition 1.915 kW | pass |
| CALC-03 | Design wind on the stowed cluster and mast | Velocity pressure 1,531 Pa; Rotor force 7.166 kN; Tower force 1.488 kN | warn |
| CALC-04 | Mast pad: overturning, sliding, bearing | Footing weight 66.08 kN; Soil cover weight 28.8 kN; Total stabilising vertical load 102.9 kN | warn |
| CALC-05 | Mast anchor rods (steel strength) | Peak anchor tension 25.47 kN; Shear per anchor 1.082 kN; Design tensile strength φNsa 94.92 kN | warn |
6. Assumptions and open questions
- A-01 (high): PLACEHOLDER: 'hive' = 7 hexagonal PV cells around a central hub on a dual-axis tracking mast.
- A-02 (high): Active cell area 10 m² at 21.5 % module efficiency.
- A-03 (high): Site: 4.5 peak sun hours fixed tilt; dual-axis tracking raises this to ≈ 6.0.
- A-04 (medium): Design wind 50 m/s, cluster stowed flat (drag coefficient 1.3 on 30 % projected area).
- A-05 (high): Allowable soil bearing 150 kPa, friction 0.45.
- G-01 [blocking] Import the Solar Hive description, sketches or patent: what does it do differently from a conventional array?
- G-02 [blocking] Custom hexagonal laminates, or standard certified modules in hexagonal frames?
- G-03 [assumable] Site, permitting authority and grid connection.
- G-04 [assumable] Geotechnical data.
7. Risks
- R-01 Tracking gain does not pay for the tracker (3×4) — Cost-per-kWh comparison with fixed tilt and single-axis
- R-02 Custom laminate certification (4×4) — Prefer certified modules in hex frames
- R-03 Self-shading inside the cluster (3×3) — Shading model; MLPE per cell
- R-04 Wind overturning on a single mast (2×5) — Stow logic with redundancy; structural review
8. Cost and roadmap
Unit cost $8,165–$24,265; NRE $52,108–$150,530 incl. contingency. Prototype: $60,273–$174,795; Pilot: $47,587–$141,421; Production: $277,348–$824,233. Estimates, not quotes (2026-11-25).
| S1 Concept intake | Concept brief and open-question register | 14 h |
| S2 Requirements and concept | Requirements baseline and selected concept | 20 h |
| S3 Decomposition and plan | Approved development plan | 27 h |
| S4 Preliminary engineering and sourcing | Traceable preliminary design and assumptions | 162 h |
| S5 Simulation and feasibility | Feasibility report and alternatives | 25 h |
| S6 Optimization and integration | Recommended configuration and trade study | 35 h |
| S7 Costing and roadmap | Costed development plan | 20 h |
| S8 Handoff and later validation | Preliminary package, RFQs and test plan | 26 h |
Exclusions: Full certification testing; Land, grid-connection fees; Taxes and duties; Patent prosecution; Operating and maintenance costs (reported separately once a duty cycle is agreed).