Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.

Handoffs and exports

Discipline packages (spec §07). Electronics goes to VX Design as a structured intake package; every other discipline gets a scope with its inputs, standards, deliverables and open questions. Nothing is sent outside without your approval.

VX Design electronics intake

vx-design-intake/1Download for VX Design

1 board(s) · 2 interface(s) · 4 power figures · 4 standards · 0 open question(s)

Preview the package
{
  "schema": "vx-design-intake/1",
  "source": {
    "product": "VX Inventor",
    "project": "Solar Hive",
    "exported": "preview"
  },
  "status": "preliminary",
  "summary": "Solar Hive: Modular hexagonal solar cells clustered on a tracking mast (placeholder reading — import the invention's description).",
  "boards": [
    {
      "ref": "1.2.4",
      "name": "Tracker controller with wind-stow",
      "function": "Sun-position tracking ±1°; stow on anemometer or power loss",
      "notes": "Routed to VX Design"
    }
  ],
  "interfaces": [
    {
      "id": "I-03",
      "kind": "signal",
      "between": [
        "Tracker controller with wind-stow",
        "Azimuth slew drive"
      ],
      "description": "Controller to slew drive and actuator",
      "defined": false
    },
    {
      "id": "I-05",
      "kind": "electrical",
      "between": [
        "DC wiring, connectors and bonding",
        "Microinverters or string inverter with MLPE"
      ],
      "description": "Cell DC outputs to inverters",
      "defined": false
    }
  ],
  "power_budget": [
    {
      "source": "CALC-01 DC output at this condition",
      "value": 1.9148,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-01 AC output at this condition",
      "value": 1.6468,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 DC output at this condition",
      "value": 1.9148,
      "unit": "kW",
      "basis": "calculated from assumptions"
    },
    {
      "source": "CALC-02 AC output at this condition",
      "value": 1.6468,
      "unit": "kW",
      "basis": "calculated from assumptions"
    }
  ],
  "environment": [
    "Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code."
  ],
  "safety": [
    "REQ-SAFE-001: Survive the design wind in stow position. (ASCE 7 basic wind speed for the site (assumed 50 m/s))",
    "REQ-SAFE-002: Stow automatically above a set wind speed and on loss of power. (stow ≤ 90 s from trigger)",
    "REQ-STR-001: The mast foundation shall resist overturning and sliding within allowable soil bearing. (FS ≥ 1.5; q ≤ q_allow)"
  ],
  "standards": [
    {
      "id": "ISO 13849-1/-2",
      "title": "Safety of machinery — Safety-related parts of control systems"
    },
    {
      "id": "IEC 61000 series",
      "title": "Electromagnetic compatibility"
    },
    {
      "id": "IEC 60529",
      "title": "Degrees of protection provided by enclosures (IP code)"
    },
    {
      "id": "IEC 60204-1",
      "title": "Safety of machinery — Electrical equipment of machines"
    }
  ],
  "requirements": [
    {
      "code": "REQ-SAFE-001",
      "text": "Survive the design wind in stow position.",
      "target": "ASCE 7 basic wind speed for the site (assumed 50 m/s)"
    },
    {
      "code": "REQ-SAFE-002",
      "text": "Stow automatically above a set wind speed and on loss of power.",
      "target": "stow ≤ 90 s from trigger"
    },
    {
      "code": "REQ-STR-001",
      "text": "The mast foundation shall resist overturning and sliding within allowable soil bearing.",
      "target": "FS ≥ 1.5; q ≤ q_allow"
    },
    {
      "code": "REQ-REG-001",
      "text": "Modules, racking and inverter listed for the jurisdiction.",
      "target": "IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690"
    }
  ],
  "open_questions": []
}

Discipline scopes

Electrical power 5 items
Items
1.1 Hexagonal PV cells; 1.1.1 PV laminates cut / built to hexagonal format; 1.1.4 DC wiring, connectors and bonding; 1.5 Power conversion and interconnection; 1.5.1 Microinverters or string inverter with MLPE
Inputs
CALC-01 Cluster output at peak sun, tracked annual energy: Cell temperature 56.25 °C, Rated DC power at STC 2.15 kW, DC output at this condition 1.9148 kW, AC output at this condition 1.6468 kW
CALC-02 Same modules on a fixed-tilt baseline: Cell temperature 56.25 °C, Rated DC power at STC 2.15 kW, DC output at this condition 1.9148 kW, AC output at this condition 1.6468 kW
Standards
IEC 61215, IEC 61730 / UL 61730, NFPA 70 (NEC) Art. 690, 694, 705, UL 3703 / UL 2703, UL 1741, IEEE 1547
Deliverables
Custom-format laminates need their own IEC 61215 qualification — or use standard rectangular modules in hex frames; NEC 690 wiring; equipment grounding continuity; Listed; rapid shutdown (NEC 690.12)
Open
G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?
Structural 5 items
Items
1.1.2 Hexagonal cell frames; 1.3 Mast; 1.3.1 Steel mast tube; 1.3.2 Mast base plate and flange bolts; 1.4.2 Anchor rods
Inputs
CALC-03 Design wind on the stowed cluster and mast: Velocity pressure 1531.3 Pa, Rotor force 7.1663 kN, Tower force 1.4884 kN, Total base shear 8.6546 kN
CALC-05 Mast anchor rods (steel strength): Peak anchor tension 25.468 kN, Shear per anchor 1.0818 kN, Design tensile strength φNsa 94.919 kN, Design shear strength φVsa 49.358 kN
Standards
UL 3703 / UL 2703, ANSI/AISC 360, ASCE/SEI 7, ISO 898-1, ASTM F1554, ACI 318
Deliverables
Frame carries 2400 Pa wind / 5400 Pa snow test loads; Member checks by structural engineer; Plate and bolt checks; Steel and breakout checks
Mechanical / machine design 5 items
Items
1.1.3 Cell-to-hub quick connectors; 1.2 Tracking head; 1.2.1 Azimuth slew drive; 1.2.2 Elevation actuator; 1.2.3 Hub slewing bearing
Standards
ISO 898-1, UL 3703 / UL 2703, ISO 13849-1/-2, ISO 281, ISO 76
Deliverables
Cell swap without tools in ≤ 30 min; bonding path maintained; Holding torque ≥ stow wind moment × 1.5; Drives to stow on backup power; Static safety ≥ 2 at stow wind moment
Civil and geotechnical 2 items
Items
1.4 Foundation; 1.4.1 Reinforced-concrete pad
Inputs
CALC-04 Mast pad: overturning, sliding, bearing: Footing weight 66.08 kN, Soil cover weight 28.8 kN, Total stabilising vertical load 102.88 kN, Overturning moment at base 33.251 kN·m
CALC-05 Mast anchor rods (steel strength): Peak anchor tension 25.468 kN, Shear per anchor 1.0818 kN, Design tensile strength φNsa 94.919 kN, Design shear strength φVsa 49.358 kN
Standards
ACI 318, ASCE/SEI 7, International Building Code (as adopted locally)
Deliverables
FS ≥ 1.5; bearing within allowable
Open
G-04: Geotechnical data.

Exports

Every export is marked preliminary. Nothing here claims certification or construction readiness.