Reference projects / Solar HiveConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Handoffs and exports
Discipline packages (spec §07). Electronics goes to VX Design as a structured intake package; every other discipline gets a scope with its inputs, standards, deliverables and open questions. Nothing is sent outside without your approval.
VX Design electronics intake
vx-design-intake/1Download for VX Design1 board(s) · 2 interface(s) · 4 power figures · 4 standards · 0 open question(s)
- 1.2.4 Tracker controller with wind-stow — Sun-position tracking ±1°; stow on anemometer or power loss
Preview the package
{
"schema": "vx-design-intake/1",
"source": {
"product": "VX Inventor",
"project": "Solar Hive",
"exported": "preview"
},
"status": "preliminary",
"summary": "Solar Hive: Modular hexagonal solar cells clustered on a tracking mast (placeholder reading — import the invention's description).",
"boards": [
{
"ref": "1.2.4",
"name": "Tracker controller with wind-stow",
"function": "Sun-position tracking ±1°; stow on anemometer or power loss",
"notes": "Routed to VX Design"
}
],
"interfaces": [
{
"id": "I-03",
"kind": "signal",
"between": [
"Tracker controller with wind-stow",
"Azimuth slew drive"
],
"description": "Controller to slew drive and actuator",
"defined": false
},
{
"id": "I-05",
"kind": "electrical",
"between": [
"DC wiring, connectors and bonding",
"Microinverters or string inverter with MLPE"
],
"description": "Cell DC outputs to inverters",
"defined": false
}
],
"power_budget": [
{
"source": "CALC-01 DC output at this condition",
"value": 1.9148,
"unit": "kW",
"basis": "calculated from assumptions"
},
{
"source": "CALC-01 AC output at this condition",
"value": 1.6468,
"unit": "kW",
"basis": "calculated from assumptions"
},
{
"source": "CALC-02 DC output at this condition",
"value": 1.9148,
"unit": "kW",
"basis": "calculated from assumptions"
},
{
"source": "CALC-02 AC output at this condition",
"value": 1.6468,
"unit": "kW",
"basis": "calculated from assumptions"
}
],
"environment": [
"Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code."
],
"safety": [
"REQ-SAFE-001: Survive the design wind in stow position. (ASCE 7 basic wind speed for the site (assumed 50 m/s))",
"REQ-SAFE-002: Stow automatically above a set wind speed and on loss of power. (stow ≤ 90 s from trigger)",
"REQ-STR-001: The mast foundation shall resist overturning and sliding within allowable soil bearing. (FS ≥ 1.5; q ≤ q_allow)"
],
"standards": [
{
"id": "ISO 13849-1/-2",
"title": "Safety of machinery — Safety-related parts of control systems"
},
{
"id": "IEC 61000 series",
"title": "Electromagnetic compatibility"
},
{
"id": "IEC 60529",
"title": "Degrees of protection provided by enclosures (IP code)"
},
{
"id": "IEC 60204-1",
"title": "Safety of machinery — Electrical equipment of machines"
}
],
"requirements": [
{
"code": "REQ-SAFE-001",
"text": "Survive the design wind in stow position.",
"target": "ASCE 7 basic wind speed for the site (assumed 50 m/s)"
},
{
"code": "REQ-SAFE-002",
"text": "Stow automatically above a set wind speed and on loss of power.",
"target": "stow ≤ 90 s from trigger"
},
{
"code": "REQ-STR-001",
"text": "The mast foundation shall resist overturning and sliding within allowable soil bearing.",
"target": "FS ≥ 1.5; q ≤ q_allow"
},
{
"code": "REQ-REG-001",
"text": "Modules, racking and inverter listed for the jurisdiction.",
"target": "IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690"
}
],
"open_questions": []
}Discipline scopes
Electrical power 5 items
- Items
- 1.1 Hexagonal PV cells; 1.1.1 PV laminates cut / built to hexagonal format; 1.1.4 DC wiring, connectors and bonding; 1.5 Power conversion and interconnection; 1.5.1 Microinverters or string inverter with MLPE
- Inputs
- CALC-01 Cluster output at peak sun, tracked annual energy: Cell temperature 56.25 °C, Rated DC power at STC 2.15 kW, DC output at this condition 1.9148 kW, AC output at this condition 1.6468 kWCALC-02 Same modules on a fixed-tilt baseline: Cell temperature 56.25 °C, Rated DC power at STC 2.15 kW, DC output at this condition 1.9148 kW, AC output at this condition 1.6468 kW
- Standards
- IEC 61215, IEC 61730 / UL 61730, NFPA 70 (NEC) Art. 690, 694, 705, UL 3703 / UL 2703, UL 1741, IEEE 1547
- Deliverables
- Custom-format laminates need their own IEC 61215 qualification — or use standard rectangular modules in hex frames; NEC 690 wiring; equipment grounding continuity; Listed; rapid shutdown (NEC 690.12)
- Open
- G-02: Custom hexagonal laminates, or standard certified modules in hexagonal frames?
Structural 5 items
- Items
- 1.1.2 Hexagonal cell frames; 1.3 Mast; 1.3.1 Steel mast tube; 1.3.2 Mast base plate and flange bolts; 1.4.2 Anchor rods
- Inputs
- CALC-03 Design wind on the stowed cluster and mast: Velocity pressure 1531.3 Pa, Rotor force 7.1663 kN, Tower force 1.4884 kN, Total base shear 8.6546 kNCALC-05 Mast anchor rods (steel strength): Peak anchor tension 25.468 kN, Shear per anchor 1.0818 kN, Design tensile strength φNsa 94.919 kN, Design shear strength φVsa 49.358 kN
- Standards
- UL 3703 / UL 2703, ANSI/AISC 360, ASCE/SEI 7, ISO 898-1, ASTM F1554, ACI 318
- Deliverables
- Frame carries 2400 Pa wind / 5400 Pa snow test loads; Member checks by structural engineer; Plate and bolt checks; Steel and breakout checks
Mechanical / machine design 5 items
- Items
- 1.1.3 Cell-to-hub quick connectors; 1.2 Tracking head; 1.2.1 Azimuth slew drive; 1.2.2 Elevation actuator; 1.2.3 Hub slewing bearing
- Standards
- ISO 898-1, UL 3703 / UL 2703, ISO 13849-1/-2, ISO 281, ISO 76
- Deliverables
- Cell swap without tools in ≤ 30 min; bonding path maintained; Holding torque ≥ stow wind moment × 1.5; Drives to stow on backup power; Static safety ≥ 2 at stow wind moment
Civil and geotechnical 2 items
- Items
- 1.4 Foundation; 1.4.1 Reinforced-concrete pad
- Inputs
- CALC-04 Mast pad: overturning, sliding, bearing: Footing weight 66.08 kN, Soil cover weight 28.8 kN, Total stabilising vertical load 102.88 kN, Overturning moment at base 33.251 kN·mCALC-05 Mast anchor rods (steel strength): Peak anchor tension 25.468 kN, Shear per anchor 1.0818 kN, Design tensile strength φNsa 94.919 kN, Design shear strength φVsa 49.358 kN
- Standards
- ACI 318, ASCE/SEI 7, International Building Code (as adopted locally)
- Deliverables
- FS ≥ 1.5; bearing within allowable
- Open
- G-04: Geotechnical data.
Exports
- Complete preliminary package (JSON) — record, calculation results with fingerprints, plan, cost, findings, verdict
- BOM (CSV) · Plan (CSV) · Requirements and traceability (CSV)
- Funding-ready report — print to PDF from the browser
Every export is marked preliminary. Nothing here claims certification or construction readiness.