Reference projects / Solar HiveConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Product structure
Recursive decomposition: system → subsystems → assemblies → parts, each with its discipline, make/buy, material or catalogue component, sizing methods, standards and acceptance criterion.
Systems engineering: 1Electrical power: 5Structural: 5Mechanical / machine design: 5Electronics / PCB (VX Design): 1Civil and geotechnical: 2
1Solar Hive cluster (placeholder architecture)Systems engineering
1.1Hexagonal PV cellsElectrical power
- Sized by
- solar.pv_output
- Standards
- IEC 61215IEC 61730 / UL 61730
- Satisfies
- REQ-PERF-001REQ-MOD-001
1.1.1PV laminates cut / built to hexagonal format ×7Electrical powertbd$1,400–4,200
- Material
- Monocrystalline silicon cells (PERC/TOPCon) (IEC 61215 / IEC 60904)
- Component type
- Crystalline-silicon PV module
- Standards
- IEC 61215IEC 61730 / UL 61730
- Acceptance
- Custom-format laminates need their own IEC 61215 qualification — or use standard rectangular modules in hex frames
- Note
- Key cost/certification question (G-02)
1.1.2Hexagonal cell frames ×7Structuralmake$700–2,100
- Material
- Aluminium 6063-T6 (ASTM B221, T6)
- Standards
- UL 3703 / UL 2703
- Acceptance
- Frame carries 2400 Pa wind / 5400 Pa snow test loads
1.1.3Cell-to-hub quick connectors ×7Mechanical / machine designmake$200–600
- Material
- Stainless steel 316 (ASTM A240 / A276, annealed)
- Sized by
- bolt.joint
- Standards
- ISO 898-1
- Acceptance
- Cell swap without tools in ≤ 30 min; bonding path maintained
1.1.4DC wiring, connectors and bondingElectrical powerbuy$150–500
- Standards
- NFPA 70 (NEC) Art. 690, 694, 705UL 3703 / UL 2703
- Acceptance
- NEC 690 wiring; equipment grounding continuity
1.2Tracking headMechanical / machine design
- Sized by
- bearing.life
- Standards
- UL 3703 / UL 2703ISO 13849-1/-2
- Satisfies
- REQ-SAFE-002
1.2.1Azimuth slew driveMechanical / machine designbuy$500–1,500
- Component type
- Single / dual-axis tracker drive
- Standards
- ISO 281
- Acceptance
- Holding torque ≥ stow wind moment × 1.5
1.2.2Elevation actuatorMechanical / machine designbuy$250–800
- Component type
- Single / dual-axis tracker drive
- Acceptance
- Drives to stow on backup power
1.2.3Hub slewing bearingMechanical / machine designbuy$400–1,200
- Component type
- Slewing ring
- Sized by
- bearing.life
- Standards
- ISO 281ISO 76
- Acceptance
- Static safety ≥ 2 at stow wind moment
1.2.4Tracker controller with wind-stowElectronics / PCB (VX Design)$300–1,200
- Standards
- ISO 13849-1/-2IEC 61000 series
- Acceptance
- Sun-position tracking ±1°; stow on anemometer or power loss
- Note
- Routed to VX Design
1.3MastStructural
- Sized by
- wind.thrustcolumn.bucklingbolt.joint
- Standards
- ANSI/AISC 360ASCE/SEI 7
- Satisfies
- REQ-SAFE-001
1.3.1Steel mast tubeStructuralmake$600–1,800
- Material
- ASTM A500 Grade C round tube (HSS) (ASTM A500, cold formed)
- Component type
- Tubular steel tower / mast
- Sized by
- wind.thrustcolumn.buckling
- Standards
- ANSI/AISC 360
- Acceptance
- Member checks by structural engineer
1.3.2Mast base plate and flange boltsStructuralmake$250–700
- Material
- ASTM A36 structural steel (ASTM A36, hot rolled)
- Component type
- Metric bolts and nuts
- Sized by
- bolt.joint
- Standards
- ANSI/AISC 360ISO 898-1
- Acceptance
- Plate and bolt checks
1.4FoundationCivil and geotechnical
- Sized by
- foundation.spread_footinganchor.bolt_circle
- Standards
- ACI 318ASCE/SEI 7International Building Code (as adopted locally)
- Satisfies
- REQ-STR-001
1.4.1Reinforced-concrete padCivil and geotechnicalmake$1,500–4,000
- Material
- Concrete f'c = 28 MPa (4000 psi) (ACI 318 / ASTM C94, 28 days)
- Component type
- Reinforced-concrete spread footing / pier
- Sized by
- foundation.spread_footing
- Standards
- ACI 318
- Acceptance
- FS ≥ 1.5; bearing within allowable
1.4.2Anchor rods ×8Structuralbuy$250–700
- Material
- Anchor rod ASTM F1554 Grade 55 (ASTM F1554)
- Component type
- Cast-in anchor rods
- Sized by
- anchor.bolt_circle
- Standards
- ASTM F1554ACI 318
- Acceptance
- Steel and breakout checks
1.5Power conversion and interconnectionElectrical power
- Standards
- UL 1741IEEE 1547NFPA 70 (NEC) Art. 690, 694, 705
- Satisfies
- REQ-REG-001
1.5.1Microinverters or string inverter with MLPEElectrical powerbuy$600–1,800
- Component type
- Wind / hybrid inverter with rectifier
- Standards
- UL 1741IEEE 1547
- Acceptance
- Listed; rapid shutdown (NEC 690.12)
Interfaces
| Id | Between | Kind | Description | Status |
|---|---|---|---|---|
| I-01 | Hexagonal cell frames ↔ Cell-to-hub quick connectors | structural | Cell frame to hub connector: wind and snow load path, bonding | to define |
| I-02 | Cell-to-hub quick connectors ↔ Hub slewing bearing | structural | Cluster hub to tracking head bearing | to define |
| I-03 | Tracker controller with wind-stow ↔ Azimuth slew drive | signal | Controller to slew drive and actuator | to define |
| I-04 | Mast base plate and flange bolts ↔ Anchor rods | structural | Mast base plate to anchor rods | to define |
| I-05 | DC wiring, connectors and bonding ↔ Microinverters or string inverter with MLPE | electrical | Cell DC outputs to inverters | to define |