Reference projects / Solar HiveConditional feasibility

Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.

Calculations

Deterministic, unit-aware methods (never language-model arithmetic). Each run records its method version, the exact inputs and a fingerprint. Inputs read the design basis ($name) and earlier results (@CALC-xx.output), so changing a value re-runs exactly what depends on it.

Design basis 16 values · 14 assumed

NameValueUnitBasisSourceUsed by
area10m²assumedA-02CALC-01, CALC-02
eta21.5%supplier_dataA-02: typical 2026 mono modulesCALC-01, CALC-02
psh6hassumedA-03 (tracked)CALC-01
psh_fixed4.5hassumedA-03 (fixed tilt)CALC-02
v_design50m/sassumedA-04CALC-03
rho1.225kg/m³standardCALC-03
stow_area3.6m²assumedA-04: 30 % of 12 m² grossCALC-03
cd_stow1.3assumedA-04CALC-03
hub_height3massumedCALC-03
mast_d0.27massumedCALC-03
mast_h3massumedCALC-03
dead_load8kNassumedCALC-04, CALC-05
footing_b2massumedCALC-04
q_allow150kPaassumedA-05CALC-04
soil_mu0.45assumedA-05CALC-04
reserve_target0.2assumed

Preliminary reserve target 20 % — capacity/demand ≥ 1.20; mandatory code factors govern (spec §06).

CALC-01 Cluster output at peak sun, tracked annual energy
Photovoltaic array output and annual yield · v1.0.0 · item 1.1 · REQ-PERF-001, REQ-PERF-002
pass

Results

Cell temperature56.25 °C
Rated DC power at STC2.15 kW
DC output at this condition1.915 kW
AC output at this condition1.647 kW
Annual energy (estimate)3,606 kWh
Specific yield1,677 kWh

Inputs used

Active cell area10 m²$area
Module efficiency at STC21.5 %$eta
Plane-of-array irradiance1,000 W/m²
Optical concentration ratio1
Ambient temperature25 °C
NOCT45 °C
Power temperature coefficient-0.35 %
System losses (wiring, inverter, soiling, mismatch)14 %
Peak sun hours (annual average)6 h$psh

Fingerprint 0cee1857255295 · rests on assumed: area, psh · method record

CALC-02 Same modules on a fixed-tilt baseline
Photovoltaic array output and annual yield · v1.0.0 · item 1.1 · REQ-PERF-002
pass

Results

Cell temperature56.25 °C
Rated DC power at STC2.15 kW
DC output at this condition1.915 kW
AC output at this condition1.647 kW
Annual energy (estimate)2,705 kWh
Specific yield1,258 kWh

Inputs used

Active cell area10 m²$area
Module efficiency at STC21.5 %$eta
Plane-of-array irradiance1,000 W/m²
Optical concentration ratio1
Ambient temperature25 °C
NOCT45 °C
Power temperature coefficient-0.35 %
System losses (wiring, inverter, soiling, mismatch)14 %
Peak sun hours (annual average)4.5 h$psh_fixed

Fingerprint 053e6d4aff82c6 · rests on assumed: area, psh_fixed · method record

CALC-03 Design wind on the stowed cluster and mast
Rotor and tower wind thrust, base reactions · v1.0.0 · item 1.3 · REQ-SAFE-001
warn

Results

Velocity pressure1,531 Pa
Rotor force7.166 kN
Tower force1.488 kN
Total base shear8.655 kN
Overturning moment at base23.73 kN·m

Inputs used

Design wind speed50 m/s$v_design
Air density1.225 kg/m³$rho
Rotor projected area3.6 m²$stow_area
Rotor thrust / drag coefficient1.3 $cd_stow
Height of rotor centre above base3 m$hub_height
Tower width / diameter0.27 m$mast_d
Tower height3 m$mast_h
Tower drag coefficient1.2
  • Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer

Fingerprint 16b533aedcbd89 · rests on assumed: v_design, stow_area, cd_stow, hub_height, mast_d, mast_h · method record

CALC-04 Mast pad: overturning, sliding, bearing
Square spread footing: overturning, sliding and soil bearing · v1.0.0 · item 1.4.1 · REQ-STR-001
warn

Results

Footing weight66.08 kN
Soil cover weight28.8 kN
Total stabilising vertical load102.9 kN
Overturning moment at base33.25 kN·m
Eccentricity0.3232 m
Peak soil pressure50.66 kPa
Minimum soil pressure0.7817 kPa
Concrete volume2.8 m³

Inputs used

Footing width B (square)2 m$footing_b
Footing thickness D0.7 m
Soil cover over footing h0.4 m
Concrete unit weight23.6 kN/m³
Soil unit weight18 kN/m³
Vertical load from structure (dead)8 kN$dead_load
Horizontal load at grade8.655 kN@CALC-03.h_total
Moment at grade23.73 kN·m@CALC-03.m_base
Allowable soil bearing pressure150 kPa$q_allow
Base friction coefficient0.45 $soil_mu
Required FS overturning1.5
Required FS sliding1.5

Checks (capacity / demand)

overturning102.9 / 33.25 kN·m
3.09 ≥ 1.5passFS ≥ 1.5 (common practice; code combinations govern)
sliding46.3 / 8.655 kN
5.35 ≥ 1.5passFS ≥ 1.5 (common practice; code combinations govern)
soil bearing150 / 50.66 kPa
2.96 ≥ 1passallowable bearing pressure from the geotechnical engineer (already includes its factor)
  • Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)

Fingerprint 0ed9952e96ba91 · rests on assumed: footing_b, dead_load, q_allow, soil_mu · method record

CALC-05 Mast anchor rods (steel strength)
Anchor bolts on a bolt circle: tension and shear (steel strength) · v1.0.0 · item 1.4.2 · REQ-STR-001
warn

Results

Peak anchor tension25.47 kN
Shear per anchor1.082 kN
Design tensile strength φNsa94.92 kN
Design shear strength φVsa49.36 kN
Tension–shear interaction0.2902

Inputs used

Number of anchors8
Bolt-circle diameter0.45 m
Anchor sizeM20
Anchor gradeF1554-55
Factored moment at base23.73 kN·m@CALC-03.m_base
Factored axial compression (dead, minimum)7.2 kN0.9*$dead_load
Factored base shear8.655 kN@CALC-03.h_total

Checks (capacity / demand)

anchor tension (steel)94.92 / 25.47 kN
3.73 ≥ 1.2passLRFD φ factors applied; plus project reserve 20 %
anchor shear (steel)49.36 / 1.082 kN
45.6 ≥ 1.2passproject reserve target 20 % (capacity/demand ≥ 1.20)
tension–shear interaction (≤ 1.2)1.2 / 0.2902
4.13 ≥ 1passACI 318 §17.8 interaction
  • Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)

Fingerprint 0aa17aea154a5d · rests on assumed: dead_load · method record