Reference projects / Solar HiveConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Calculations
Deterministic, unit-aware methods (never language-model arithmetic). Each run records its method version, the exact inputs and a fingerprint. Inputs read the design basis ($name) and earlier results (@CALC-xx.output), so changing a value re-runs exactly what depends on it.
Design basis 16 values · 14 assumed
Preliminary reserve target 20 % — capacity/demand ≥ 1.20; mandatory code factors govern (spec §06).
CALC-01 Cluster output at peak sun, tracked annual energy
Photovoltaic array output and annual yield · v1.0.0 · item 1.1 · REQ-PERF-001, REQ-PERF-002pass
Results
| Cell temperature | 56.25 °C |
| Rated DC power at STC | 2.15 kW |
| DC output at this condition | 1.915 kW |
| AC output at this condition | 1.647 kW |
| Annual energy (estimate) | 3,606 kWh |
| Specific yield | 1,677 kWh |
Inputs used
| Active cell area | 10 m² | $area |
| Module efficiency at STC | 21.5 % | $eta |
| Plane-of-array irradiance | 1,000 W/m² | |
| Optical concentration ratio | 1 | |
| Ambient temperature | 25 °C | |
| NOCT | 45 °C | |
| Power temperature coefficient | -0.35 % | |
| System losses (wiring, inverter, soiling, mismatch) | 14 % | |
| Peak sun hours (annual average) | 6 h | $psh |
Fingerprint 0cee1857255295 · rests on assumed: area, psh · method record
CALC-02 Same modules on a fixed-tilt baseline
Photovoltaic array output and annual yield · v1.0.0 · item 1.1 · REQ-PERF-002pass
Results
| Cell temperature | 56.25 °C |
| Rated DC power at STC | 2.15 kW |
| DC output at this condition | 1.915 kW |
| AC output at this condition | 1.647 kW |
| Annual energy (estimate) | 2,705 kWh |
| Specific yield | 1,258 kWh |
Inputs used
| Active cell area | 10 m² | $area |
| Module efficiency at STC | 21.5 % | $eta |
| Plane-of-array irradiance | 1,000 W/m² | |
| Optical concentration ratio | 1 | |
| Ambient temperature | 25 °C | |
| NOCT | 45 °C | |
| Power temperature coefficient | -0.35 % | |
| System losses (wiring, inverter, soiling, mismatch) | 14 % | |
| Peak sun hours (annual average) | 4.5 h | $psh_fixed |
Fingerprint 053e6d4aff82c6 · rests on assumed: area, psh_fixed · method record
CALC-03 Design wind on the stowed cluster and mast
Rotor and tower wind thrust, base reactions · v1.0.0 · item 1.3 · REQ-SAFE-001warn
Results
| Velocity pressure | 1,531 Pa |
| Rotor force | 7.166 kN |
| Tower force | 1.488 kN |
| Total base shear | 8.655 kN |
| Overturning moment at base | 23.73 kN·m |
Inputs used
| Design wind speed | 50 m/s | $v_design |
| Air density | 1.225 kg/m³ | $rho |
| Rotor projected area | 3.6 m² | $stow_area |
| Rotor thrust / drag coefficient | 1.3 | $cd_stow |
| Height of rotor centre above base | 3 m | $hub_height |
| Tower width / diameter | 0.27 m | $mast_d |
| Tower height | 3 m | $mast_h |
| Tower drag coefficient | 1.2 |
- Static preliminary load: gust, dynamic and code load factors must be applied by the structural engineer
Fingerprint 16b533aedcbd89 · rests on assumed: v_design, stow_area, cd_stow, hub_height, mast_d, mast_h · method record
CALC-04 Mast pad: overturning, sliding, bearing
Square spread footing: overturning, sliding and soil bearing · v1.0.0 · item 1.4.1 · REQ-STR-001warn
Results
| Footing weight | 66.08 kN |
| Soil cover weight | 28.8 kN |
| Total stabilising vertical load | 102.9 kN |
| Overturning moment at base | 33.25 kN·m |
| Eccentricity | 0.3232 m |
| Peak soil pressure | 50.66 kPa |
| Minimum soil pressure | 0.7817 kPa |
| Concrete volume | 2.8 m³ |
Inputs used
| Footing width B (square) | 2 m | $footing_b |
| Footing thickness D | 0.7 m | |
| Soil cover over footing h | 0.4 m | |
| Concrete unit weight | 23.6 kN/m³ | |
| Soil unit weight | 18 kN/m³ | |
| Vertical load from structure (dead) | 8 kN | $dead_load |
| Horizontal load at grade | 8.655 kN | @CALC-03.h_total |
| Moment at grade | 23.73 kN·m | @CALC-03.m_base |
| Allowable soil bearing pressure | 150 kPa | $q_allow |
| Base friction coefficient | 0.45 | $soil_mu |
| Required FS overturning | 1.5 | |
| Required FS sliding | 1.5 |
Checks (capacity / demand)
| overturning | 102.9 / 33.25 kN·m | 3.09 ≥ 1.5 | pass | FS ≥ 1.5 (common practice; code combinations govern) | |
| sliding | 46.3 / 8.655 kN | 5.35 ≥ 1.5 | pass | FS ≥ 1.5 (common practice; code combinations govern) | |
| soil bearing | 150 / 50.66 kPa | 2.96 ≥ 1 | pass | allowable bearing pressure from the geotechnical engineer (already includes its factor) |
- Preliminary: site-specific geotechnical report and code load combinations required (ACI 318, ASCE 7, local building code)
Fingerprint 0ed9952e96ba91 · rests on assumed: footing_b, dead_load, q_allow, soil_mu · method record
CALC-05 Mast anchor rods (steel strength)
Anchor bolts on a bolt circle: tension and shear (steel strength) · v1.0.0 · item 1.4.2 · REQ-STR-001warn
Results
| Peak anchor tension | 25.47 kN |
| Shear per anchor | 1.082 kN |
| Design tensile strength φNsa | 94.92 kN |
| Design shear strength φVsa | 49.36 kN |
| Tension–shear interaction | 0.2902 |
Inputs used
| Number of anchors | 8 | |
| Bolt-circle diameter | 0.45 m | |
| Anchor size | M20 | |
| Anchor grade | F1554-55 | |
| Factored moment at base | 23.73 kN·m | @CALC-03.m_base |
| Factored axial compression (dead, minimum) | 7.2 kN | 0.9*$dead_load |
| Factored base shear | 8.655 kN | @CALC-03.h_total |
Checks (capacity / demand)
| anchor tension (steel) | 94.92 / 25.47 kN | 3.73 ≥ 1.2 | pass | LRFD φ factors applied; plus project reserve 20 % | |
| anchor shear (steel) | 49.36 / 1.082 kN | 45.6 ≥ 1.2 | pass | project reserve target 20 % (capacity/demand ≥ 1.20) | |
| tension–shear interaction (≤ 1.2) | 1.2 / 0.2902 | 4.13 ≥ 1 | pass | ACI 318 §17.8 interaction |
- Steel strength only: concrete breakout, pull-out and side-face blowout govern many tower anchorages (ACI 318 ch. 17)
Fingerprint 0aa17aea154a5d · rests on assumed: dead_load · method record