Reference projects / Solar HiveConditional feasibility
Reference project — read-only and public. Every number on these pages is computed live by the calculation engine from the stated design basis. Copy it into a project to change assumptions, resolve gaps and work with the agent.
Brief and requirements
Concept brief
- Function
- Generate electricity from sunlight with a modular, expandable cluster that tracks the sun.
- Environment
- Outdoor, ground-mounted, −20 to +45 °C, wind and snow per local code.
- Scale
- Prototype: 7 hexagonal cells, ≈ 10 m² active area (assumed).
- Budget
- Not yet stated.
- Constraints
- Modules certified to IEC 61215 / 61730 · Tracker must stow in high wind · Compare against a fixed-tilt array of the same modules
Requirements and traceability
Requirement → parts → calculations / tests (spec §03). “Assumed” means the supporting calculation rests on values not yet confirmed.
| Code | Requirement | Target | Verified by | Allocated to | Evidence |
|---|---|---|---|---|---|
| REQ-PERF-001critical | Rated DC output of the prototype cluster. | ≥ 2 kW DC at STC | test | 1, 1.1 | assumedCALC-01 |
| REQ-PERF-002critical | Annual energy shall be compared with a fixed-tilt array using the same modules. | kWh/kWp with uncertainty | analysis | 1 | assumedCALC-01CALC-02 |
| REQ-SAFE-001critical | Survive the design wind in stow position. | ASCE 7 basic wind speed for the site (assumed 50 m/s) | analysis | 1.3 | assumedCALC-03 |
| REQ-SAFE-002critical | Stow automatically above a set wind speed and on loss of power. | stow ≤ 90 s from trigger | test | 1.2 | test planned |
| REQ-STR-001critical | The mast foundation shall resist overturning and sliding within allowable soil bearing. | FS ≥ 1.5; q ≤ q_allow | analysis | 1.4 | assumedCALC-04CALC-05 |
| REQ-MOD-001 | Cells shall be added or replaced without disturbing neighbouring cells. | one cell swap ≤ 30 min | demonstration | 1.1 | test planned |
| REQ-REG-001 | Modules, racking and inverter listed for the jurisdiction. | IEC 61215/61730, UL 2703/3703, UL 1741, NEC 690 | inspection | 1.5 | test planned |
| REQ-LIFE-001 | Design life. | 25 years (modules), 20 years (tracker drives) | analysis | 1 | none |